Audi A4. Body repair manual - part 60

 

  Index      Audi     Audi A4 - body repair manual 2002 year

 

Search            

 

 

 

 

 

 

 

 

 

Content   ..  58  59  60  61   ..

 

 

Audi A4. Body repair manual - part 60

 

 

Instrument cluster with long service life, On Board Diagnostic (OBD) (from m.y. 2000)
Channel 2 Adaptation 1
Indicated on display: Service event is displayed
- 1 3-
1 - means service is active, this means that "SERVICE!" is displayed in
the instrument cluster.
- Press button.
Channel 2 Adaptation 1
Indicated on display:
Input adaptation value XXXXX
Service event is reset using the following adaptation values:
Adaptation value
Service event
00000
Reset
- Using the keypad enter the appropriate adaptation value (00000) to
erase the service.
- Press -0- button five times.
Instrument cluster with long service life, On Board Diagnostic (OBD) (from m.y. 2000)
Channel 2 Adaptation 1
Q
Indicated on display:
Input adaptation value 00000
- Press -Q- button to confirm input.
Channel 2 Adaptation 0
Q
Indicated on display:
- 1 3-
0 - means service is reset, meaning that "SERVICE in 8000 mi (Marelli
instrument cluster) or 8100 mi (VDO instrument cluster)" is displayed in
instrument cluster after confirming with Q button.
Note:
The display of 8000 or 8100 miles is the starting value for the service
display.
- Press -Q- button to confirm input.
Channel 2 Adaptation 0
Q
Indicated on display:
Store changed value?
- Press -Q- button to confirm input.
Channel 2 Adaptation 0
Indicated on display:
Store changed value?
- Press the button to complete the reset of the SRI.
Instrument cluster with long service life, On Board Diagnostic (OBD) (from m.y. 2000)
Adaptation of fuel consumption display
Rapid data transfer
HELP
Indicated on display
Select function XX
- Press -1- and -0- and confirm by pressing the -Q- button.
Rapid data transfer
Q
Indicated on display
10 - Adaptation
- Press -Q- button to confirm input.
Adaptation
Indicated on display:
Input channel number XX
- Press buttons -0- and -3-.
- Press -Q- button to confirm input.
Notes:
Adaptation only for vehicles with on board computer.
Value entered must be between 85% and 115%.
Value must be entered in steps of 5%.
If the value "100" was changed due to a customer complaint, the
changed value must be transferred when replacing instrument cluster.
Channel 3 Adaptation 100
Indicated on display:
Consumption display
- 1 3-
- Press button.
Instrument cluster with long service life, On Board Diagnostic (OBD) (from m.y. 2000)
Note:
Correction of fuel consumption display is only
possible via direct input.
Channel 3 Adaptation 100
Indicated on display:
Input adaptation value XXXXX
- Input desired correction value using scan tool keypad, filling initial
positions with "0".
Example:
Desired input value: 90%
Keypad input: 00090
Channel 3 Adaptation 100
Q
Indicated on display:
Input adaptation value 00090
- Press -Q- button to confirm input.
Channel 3 Adaptation 90
Q
Indicated on display:
Consumption display
- 1 3-
- Press -Q- button to confirm input.
Channel 3 Adaptation 90
Q
Indicated on display:
Store changed value?
- Press -Q- button to confirm input.
Channel 3 Adaptation 90
Indicated on display:
Changed value is stored
-
Conclude adaptation of the fuel consumption display by pressing the
Instrument cluster with long service life, On Board Diagnostic (OBD) (from m.y. 2000)
Instrument cluster with long service life, On Board Diagnostic (OBD) (from m.y. 2000)
Rapid data transfer
HELP
Indicated on display
Select function XX
- Press -1- and -0- and confirm by pressing the -Q- button.
Rapid data transfer
Q
Indicated on display
10 - Adaptation
- Press -Q- button to confirm input.
Note:
If input is incorrect, tester switches to function mode.
Function is unknown or
Indicated on display:
cannot
be carried out at the moment
- Press button.
- Select "Adaptation" function 10 again and select adaptation channel
03.
- Perform correction of fuel gauge again.
Instrument cluster with long service life, On Board Diagnostic (OBD) (from m.y. 2000)
Language version of driver information
display
Rapid data transfer
HELP
Indicated on display
Select function XX
- Press -1- and -0- and confirm by pressing the -Q- button.
Rapid data transfer
Q
Indicated on display
10 - Adaptation
- Press -Q- button to confirm input.
Adaptation
Indicated on display:
Input channel number XX
- Press buttons -0- and -4-.
- Press -Q- button to confirm input.
Channel 4 Adaptation 1
Indicated on display:
Language
- 1 3-
Notes:
Display indicates only the last digit of the five digit language version
code, for example, 1 for German.
If incorrect value is input "Adaptation" function is terminated and
"Adaptation" function 10 must be initiated again.
Code can now be entered using the scan tool keypad in steps or via
direct input.
Instrument cluster with long service life, On Board Diagnostic (OBD) (from m.y. 2000)
Coding table:
Code
Language version
00001
German
00002
English
00003
French
00004
Italian
00005
Spanish
00006
Portuguese
Instrument cluster with long service life, On Board Diagnostic (OBD) (from m.y. 2000)
Input in steps:
- Code can be decreased using button 1 and
increased using button 3, for example, to 2 for
language version English.
Channel 4 Adaptation 2
Q
Indicated on display:
Language
- 1 3-
- Press -Q- button to confirm input.
Channel 4 Adaptation 2
Q
Indicated on display:
Store changed value?
- Press -Q- button to confirm input.
Channel 4 Adaptation 2
Indicated on display:
Changed value is stored
- Conclude adaptation of language version by pressing the button.
Instrument cluster with long service life, On Board Diagnostic (OBD) (from m.y. 2000)
Direct input:
Channel 4 Adaptation 1
Indicated on display:
Language
- 1 3-
- Press button.
Channel 4 Adaptation 1
Indicated on display:
Input adaptation value XXXXX
Coding: 2 (English)
Input value: 00002
- Press -Q- button to confirm input.
Channel 4 Adaptation 1
Q
Indicated on display:
Input adaptation value 00002
- Press -Q- button to confirm input.
Instrument cluster with long service life, On Board Diagnostic (OBD) (from m.y. 2000)
Channel 4 Adaptation 2
Q
Indicated on display:
Language
- 1 3-
- Press -Q- button to confirm input.
Channel 4 Adaptation 2
Q
Indicated on display:
Store changed value?
- Press -Q- button to confirm input.
Channel 4 Adaptation 2
Indicated on display:
Changed value is stored
- Conclude adaptation of language version by pressing the button.
Instrument cluster with long service life, On Board Diagnostic (OBD) (from m.y. 2000)
Odometer display
This function is used to adapt the odometer after
the instrument cluster is replaced.
Notes:
The adaptation is only possible for an
instrument cluster with a maximum mileage of
100 miles.
Adaptation can only be performed once for
each instrument cluster.
Only larger adaptation values can be entered
(more than 100 miles).
If an incorrect value is entered and confirmed, it
cannot be changed. If this happens, the
instrument cluster must be replaced.
In countries where speedometers are calibrated
in miles, adaptation can be performed in miles.
Observe notes when replacing instrument
cluster
Instrument cluster with long service life, On Board Diagnostic (OBD) (from m.y. 2000)
Rapid data transfer
HELP
Indicated on display:
Select function XX
- Press buttons -1- and 1-. This selects "Login Procedure" function 11.
Rapid data transfer
Q
Indicated on display:
11 - Login-Procedure
- Press -Q- button to confirm input.
Login-Procedure
Indicated on display:
Input code number XXXXX
- Input code number 13861.
Login-Procedure
Q
Indicated on display:
Input code number 13861
- Press -Q- button to confirm input.
Rapid data transfer
HELP
Indicated on display:
Select function XX
- Press buttons -1- and -0-.
Rapid data transfer
Q
Indicated on display:
10 - Adaptation
- Press -Q- button to confirm input.
Adaptation
Indicated on display:
Input channel number XX
- Press buttons -0- and -9-.

 

 

 

 

 

 

 

Content   ..  58  59  60  61   ..