Instrument cluster with long service life, On Board Diagnostic (OBD) (from m.y. 2000)
- Press -Q- button to confirm input.
Channel 9 Adaptation 0
Indicated on display:
Mileage in 10 miles
- 1 3-
Note:
For the VAG1551 scan tool values can only be input via direct input.
- Press the button to continue program sequence.
Channel 9 Adaptation 0
Q
Indicated on display:
Input adaptation value XXXXX
Example:
Mileage = 89627
0 8 9 6 3
X
Hundred thousands: 100000 - 655350
X
Ten thousands: 10000 - 90000
X
Thousands: 1000 - 9000
X
Hundreds: 100 - 900
X Tens: 10 - 90
Ones: round to nearest ten
Instrument cluster with long service life, On Board Diagnostic (OBD) (from m.y. 2000)
Channel 9 Adaptation 0
Q
Indicated on display:
Input adaptation value 08963
- Press -Q- button to confirm input.
Channel 9 Adaptation 8963
Q
Indicated on display:
Mileage in 10 miles
- 1 3-
- Press -Q- button to confirm input.
Channel 9 Adaptation 8963
Q
Indicated on display:
Store changed value?
- Press -Q- button to confirm input.
Channel 9 Adaptation 8963
Indicated on display:
Changed value is stored
- End adaptation of odometer by pressing the button.
Instrument cluster with long service life, On Board Diagnostic (OBD) (from m.y. 2000)
Adaptation of auxiliary heater
Rapid data transfer
HELP
Indicated on display
Select function XX
- Press -1- and -0- and confirm by pressing the -Q- button.
Rapid data transfer
Q
Indicated on display
10 - Adaptation
- Press -Q- button to confirm input.
Adaptation
Indicated on display:
Input channel number XX
- Press buttons 1- and -8-.
- Press -Q- button to confirm input.
Instrument cluster with long service life, On Board Diagnostic (OBD) (from m.y. 2000)
Channel 18 Adaptation 0
- Indicated on display: Adaptation value is displayed, for example 0.
- 1 3-
Notes:
Adaptation value "0" is input if auxiliary heater is not installed.
Adaptation value "1" is input if an auxiliary heater is installed that is
independent of engine condition (running or not).
Adaptation value "10" is input if an auxiliary heater is installed that
switches off when engine is not running.
- Press button.
Channel 18 Adaptation 0
Indicated on display:
Input adaptation value XXXXX
- Input adaptation value using keypad, filling initial positions with "0", for
example 00001.
Channel 18 Adaptation 0
Q
Indicated on display:
Input adaptation value 00001
- Press -Q- button to confirm input.
Instrument cluster with long service life, On Board Diagnostic (OBD) (from m.y. 2000)
Channel 18 Adaptation 1
Q
Indicated on display:
- 1 3-
- Press -Q- button to confirm input.
Channel 18 Adaptation 1
Q
Indicated on display:
Store changed value?
- Press -Q- button to confirm input.
Channel 18 Adaptation 1
Indicated on display:
Changed value is stored
- End adaptation of the auxiliary heater by pressing the button.
Instrument cluster with long service life, On Board Diagnostic (OBD) (from m.y. 2000)
Adaptation of fuel gauge sender resistance
range
This function is used to adjust the fuel gauge
sender resistance range if the fuel gauge display
in the instrument cluster does not match the
actual amount of fuel in the tank.
Rapid data transfer
HELP
Indicated on display
Select function XX
- Press -1- and -0- and confirm by pressing the -Q- button.
Rapid data transfer
Q
Indicated on display
10 - Adaptation
- Press -Q- button to confirm input.
Adaptation
Indicated on display:
Input channel number XX
- Press buttons -3- and -0-.
- Press -Q- button to confirm input.
Instrument cluster with long service life, On Board Diagnostic (OBD) (from m.y. 2000)
Channel 30 Adaptation 128
Indicated on display: Adaptation value is displayed, for example 128.
Tank sender
- 1 3-
Notes:
"128" is the adaptation value for the standard resistance range for the
fuel gauge sender as set by the factory.
The resistance value for the fuel gauge sender resistance range can
be adjusted by
8 Ohm to give an adaptation value between 120 and
136.
If the value "128" was changed due to a customer complaint, the
changed value must be transferred when replacing instrument cluster.
- Press button.
Channel 30 Adaptation 128
Indicated on display:
Input adaptation value XXXXX
- Input desired correction value using scan tool keypad, filling initial
positions with "0" and watch how the display responds.
Example:
Desired input value: 132
Keypad input: 00132
Channel 30 Adaptation 128
Q
Indicated on display:
Input adaptation value 00132
- Press -Q- button to confirm input.
Instrument cluster with long service life, On Board Diagnostic (OBD) (from m.y. 2000)
Channel 30 Adaptation 132
Q
Indicated on display:
Tank sender
- 1 3-
- Press -Q- button to confirm input.
Channel 30 Adaptation 132
Q
Indicated on display:
Store changed value?
- Press -Q- button to confirm input.
Channel 30 Adaptation 132
Indicated on display:
Changed value is stored
- End adaptation of the fuel gauge sender resistance range by pressing
the button.
Instrument cluster with long service life, On Board Diagnostic (OBD) (from m.y. 2000)
Adaptation of the engine speed threshold
This function is used to adapt the offset value for
the engine speed threshold to the dynamic oil
pressure warning.
Rapid data transfer
HELP
Indicated on display
Select function XX
- Press -1- and -0- and confirm by pressing the -Q- button.
Rapid data transfer
Q
Indicated on display
10 - Adaptation
- Press -Q- button to confirm input.
Adaptation
Indicated on display:
Input channel number XX
- Press buttons -3- and 5-.
- Press -Q- button to confirm input.
Instrument cluster with long service life, On Board Diagnostic (OBD) (from m.y. 2000)
Channel 35 Adaptation 0
Indicated on display: Adaptation value is displayed, for example 0.
- 1 3-
Notes:
The adaptation value of 0 corresponds to the value set at the factory
for the oil pressure warning if the oil pressure drops below 1.2 bar at
1500 rpm.
The adaptation can be performed in four steps (0-1000).
The adaptation value of "250" changes the engine speed threshold to
1750 rpm.
If the value "0" was changed due to a customer complaint, the
changed value must be transferred when replacing instrument cluster.
- Press button.
Channel 35 Adaptation 0
Indicated on display:
Input adaptation value XXXXX
- Input adaptation value using keypad, filling initial positions with "0", for
example, 00250.
Channel 35 Adaptation 0
Q
Indicated on display:
Input adaptation value 00250
- Press -Q- button to confirm input.
Instrument cluster with long service life, On Board Diagnostic (OBD) (from m.y. 2000)
Channel 35 Adaptation 250
Q
Indicated on display:
- 1 3-
- Press -Q- button to confirm input.
Channel 35 Adaptation 250
Q
Indicated on display:
Store changed value?
- Press -Q- button to confirm input.
Channel 35 Adaptation 250
Indicated on display:
Changed value is stored
- End adaptation of the engine speed threshold by pressing the
button.
Instrument cluster with long service life, On Board Diagnostic (OBD) (from m.y. 2000)
Distance driven since service
This function is used to input the distance in
miles since the last service.
Rapid data transfer
HELP
Indicated on display
Select function XX
- Press -1- and -0- and confirm by pressing the -Q- button.
Rapid data transfer
Q
Indicated on display
10 - Adaptation
- Press -Q- button to confirm input.
Adaptation
Indicated on display:
Input channel number XX
- Press buttons -4- and -0-.
- Press -Q- button to confirm input.
Channel 40 Adaptation 8
Indicated on display: The display indicates the number of miles driven
since the last service (here for example, 8 indicates 800 miles)
Actual value Insp. in 100 Miles
- 1 3-
Instrument cluster with long service life, On Board Diagnostic (OBD) (from m.y. 2000)
Notes:
Input of current specified value is only possible
in units of 100 miles, therefore indication in
display also changes in 100 mile units.
Observe notes when replacing instrument
cluster
tool keypad.

 

 

 

 

 

 

 