S
YSTEM
3. Dual ring configuration to the extent possible
4. Easy to install and operate
5. Compact design
A digital transmission system, based on state-of-the-art fibre optic technology, shall be required to
carry all voice, data, LAN and video information, as shown in the Contract Plans and directed by the
Engineer. Usage of copper cable for long-distance transmission purposes that exceeds 90 m shall
not be allowed due to the inherent disadvantages of copper cable (attenuation of signals,
susceptibility to electromagnetic influences and high costs for cable sizes necessary to carry the
required amount of signals).
An IP-based transmission system with Ethernet switches shall carry all channels for voice, data, LAN
and video communications. As virtually all information is transmitted via the IP network, the system
shall be implemented using two physically independent cable routes wherever applicable and
possible and as approved by the Engineer. In case of a partial network failure, this will ensure that
the remaining part is not affected. The network shall be logically configured by VLANs (virtual local
area network) which allow separation of the various types of flow (video, voice, data, order, etc.) and
allows affecting a different priority level to them so that there is no disturbance in the transfer of
information as approved by the Engineer.
9.6.2.9
Network Management System
Subcontractor shall furnish, install, configure, and integrate a network management system (NMS)
to monitor, manage and administrate the traffic management system communication network
(TMSCN) as shown in the Contract plans, as directed by the Engineer. The NMS shall be compatible
with the
Employer’s legacy NMS. The NMS shall be a powerful and flexible open platform network
infrastructure (hardware and software) management tool, providing enhanced features to manage
the TMSCN connected systems and components, and shall include all necessary NMS equipment -
servers, switches, routers, firewalls, etc as shown on the
Subcontractor’s approved Drawings. Such
as system fibre and Ethernet switches regardless of the model, shall deliver customizable network
management capabilities that scale to meet the needs of the largest and advanced networks.
NMS shall include network configuration and change management functionality, giving control over
bulk configurations and scheduling. It shall be able to create detailed audit trails of network changes,
to perform firmware upgrades and to manage the software configuration of the networked devices.
NMS shall be able to represent the status of the network using several graphics approach. NMS
shall be fully client-server and supports multiple distributed users with varying access levels and
individualized network resource control.
NMS shall be supplied with enough capacity and licenses to cover all the TMSCN systems with
additional spare capacity of 50 %.The NMS shall be integrated as ATMS component so that the
operator in the control room can see and take action on the alarm coming from NMS. NMS shall
support open protocols to permit the control of multiple suppliers. NMS shall visualize, monitor and
pro-actively manage the network, including analyzing traffic loads and generating statistical trend
reports. NMS shall support multiple vendors, softwares and ensure compatibility with major suppliers
including but not limited to: Cisco, Moxa and Juniper.
a. Field Equipment Cabinet Remote Switch
Subcontractor shall furnish, install, and configure a field equipment cabinet remote switch (FRS)
–
access field switch - in field equipment cabinets (FEC) to interface the ITS field devices with the fibre
optics or Ethernet communication backbone as directed by Engineer.
FRS switch shall be an industrial class, fan less, modular and layer 2 managed fibre Ethernet switch.
As a minimum, standard layer 2 switches are required, however, layer 3 switches are acceptable or
desired. Switch shall be of reconfigurable model in which the type of ports and modules of each
switch can be configured as needed based on the location of the switch as approved by the Engineer
and as shown in Contract plans. Subcontractor will be requested to keep some modules as spare to
be used when needed as directed by the Engineer. FRS shall comply with the following
requirements: