Abu Dhabi, United Arab Emirates. STANDARD CONSTRUCTION SPECIFICATIONS (PART 1 - ROADS, Second Edition 2020) - page 53

 

  Главная      Manuals     Abu Dhabi, United Arab Emirates. STANDARD CONSTRUCTION SPECIFICATIONS (PART 1 - ROADS, Second Edition 2020)

 

Search            copyright infringement  

 

 

 

 

 

 

 

 

 

 

 

Content      ..     51      52      53      54     ..

 

 

 

Abu Dhabi, United Arab Emirates. STANDARD CONSTRUCTION SPECIFICATIONS (PART 1 - ROADS, Second Edition 2020) - page 53

 

 

S

YSTEM

 

 

Subcontractor  shall  perform  all  required  performance  and  reliability  tests,  as  specified  in  Article 
9.6.3.1. 

9.5.3.7 

Other Subsystem Configurations 

Descriptions and detailed Specifications that are included in the Contract Documents are intended 
to be as definitive as possible.  However, they are not meant to preclude other possible subsystem 
configurations.    Subcontractors  who  have  well-developed  hardware  or  software  subsystems  that 
differ from those described or specified shall submit with their Tender all details and particulars of 
their subsystems. Consideration will be given to alternative configurations, provided that they show 
major  advantages  without  a  sacrifice  in  performance,  compatibility  with  the  existing  traffic  control 
system, maintainability or reliability.  However, after the execution of the Contract, no substitution 
shall be made unless approved in advance by the Engineer in writing. 

9.5.3.8 

Installation of Pedestrian Signal Heads 

Under this Contract the Subcontractor shall furnish and install all pedestrian signal heads, control 
mechanisms  and  cables  within  sidewalk  pylons  or  on  poles  as  provided  and  installed  for  the 
respective intersection, interchange or roadway construction as directed by the Engineer. 

To ensure correct positioning of the equipment installed under this Contract, the Subcontractor shall 
be responsible for coordination with the work executed under separate contracts in accordance with 
the requirements of respective Clauses under Department of Transport Conditions of Contract and 
Further Requirements in the Contract Documents. 

9.5.3.9 

Installation of Controller Communication Cables 

All cable shall be installed, spliced, connected to terminal strips, tested and connected to the proper 
equipment  to  produce  a  complete  and  operating  traffic  control  system.    Cables  shall  be  pulled 
through the conduit with a cable grip designed to provide a firm hold on the exterior covering of the 
cable.  All cable shall be pulled with a minimum of dragging on the ground or pavement. 

Cable feeders shall be used.  Powered soapstone, talc or other approved lubricants shall be used to 
facilitate the pulling of the cable through the conduit. 

Cable  ends  shall  be  taped  to  exclude  moisture  until  the  connections  are  made  or  the  terminals 
attached.  Cable shield shall be connected to terminals to provide electrical continuity.  Cables shall 
enter junction boxes through the bottom only.  Drop loops shall be provided in cables. 

9.5.3.10 

Installation of Electrical Components and Accessories 

Installation of all electrical equipment for the traffic control system shall meet the requirements as 
specified in this section as well as the applicable sections and clauses of Chapter 10, Lighting and 
Electrical Distribution Works. 

9.6 

Intelligent Transportation Systems 

9.6.1 

 Description 

This Specification covers descriptions and requirements of the components and materials forming 
part  of  the  intelligent  transportation  systems.  All  components,  items,  systems  and  sub-systems 
supplied  and/or  implemented  under  this  Contract  shall  strictly  comply  with  requirements  and 
specifications  stipulated  in  this  Specification  and  the  Abu  Dhabi 

Traffic  Signals  and  Electronic 

Warning and Information Manual

.  System shall be compatible, and capable of integration with any 

existing system, and operate in harmony with the existing system. 

All  non-civil  works  required  under  this  section  shall  be  executed  by  an  Owner  pre-approved 
Subcontractor (from herein referred to as Subcontractor).  Subcontractor shall be a well established 
ITS contractor and shall have carried out a number of works of similar nature and magnitude as this 
Contract.  Subcontractor shall have previous experience in the hardware, software, principles and 

S

YSTEM

 

 

operational aspects of ITS, and shall be technically capable of integrating the ITS equipment installed 
under this Contract with a new or existing central system, such that full compatibility is ensured. 

Subcontractor  shall  have the necessary  experience  and resources  to furnish,  install,  operate  and 
maintain all components of the intelligent transportation system such as equipment, cabinets, poles, 
gantries, power supply panels, video and data communications system, cabling and wiring, and all 
other  components  as  may  be  specified  herein,  shown  on  the  Contract  plans  or  required  in  the 
Particular Specifications. 

Unit rates entered in the Bill of Quantities must include for all work as specified plus all on costs for 
the  main  Contractor's  work,  attendance,  overhead  and  profit.    Any  other  items  necessary  for  the 
satisfactory completion of the works but not specifically mentioned in the Contract  Documents will 
be considered as subsidiary obligations to this Contract. 

Main Contractor will be held responsible for the overseeing of the Subcontractors work, including the 
scheduling, submittals, procurement and the ultimate acceptance of the ITS works so that all works 
are completed by the Contract completion date. 

9.6.1.1 

General System Overview 

Intelligent  transportation  systems  (ITS)  provides  monitoring,  detection,  verification,  traveller 
information and response for traffic and transport related incidents, events, and accidents  as may 
be existing or proposed new in and adjacent to the Project area by utilizing the latest technology, 
hardware and software, and up-to-date traffic engineering principles and procedures.   

ITS provided under this Contract shall be fully compatible with any existing ITS system deployed by 
the  Owner  at  the  time  of  project  initiation,  or  planned  system  expected to  be  deployed  at  project 
completion  at  the  discretion  of  the  Owner.  ITS  central  system  and  subsystems  deployed  in  this 
Contract shall comply with the requirements of the Abu Dhabi 

Traffic Signals and Electronic Warning 

and Information Manual

.  

9.6.2 

Materials 

9.6.2.1 

General  

Materials of all parts used in the ITS shall be new and the best of their respective kind and the most 
suitable  for  working  under  the  weather  and  site  conditions  set  out  in  these  Specifications,  thus 
withstanding  the  variations  of  temperatures  and  other  prevailing  conditions  without  distortion  or 
deterioration of any part of the ITS. 

Equipment included in these Specifications shall be so manufactured as to facilitate easy and proper 
erection and maintenance.   Design of all equipment shall ensure satisfactory operation under the 
weather and site conditions mentioned. 

In general, dissimilar metals in contact shall be avoided.  When, however, they have to be used, the 
contact points of dissimilar metals shall be adequately protected against galvanic corrosion. 

It  is  the  intent  of  this  Specifications  that  the  Subcontractor  shall  be  the  supplier  and  installer  (or 
manufacturer  and  installer)  of  the  main  items  of  the  ITS  meeting  the  requirements  of  the 
Specifications and Contract plans.  Subcontractor shall submit for review and approval a complete 
list of equipment, and the associated model numbers and materials that are proposed for use.  The 
list shall include descriptive literature, technical details and drawings sufficient to fully describe and 
explain the specified components of the intelligent transportation system and its integration with the 
existing traffic control system, if required, and the existing or new central system as approved by the 
Engineer and the Owner.  Where specified herein or when required by the Engineer, samples of any 
of the materials and equipment proposed for use shall be submitted for review and approval. 

It  shall  be  the  responsibility  of  the  Subcontractor  to  ensure  that  all  items  supplied  for  use  in  this 
project comply with the Specifications and approval of the Engineer. Subcontractor shall not procure 
any equipment until the material submittal and applicable shop drawing has been approved by the 
Engineer. 

S

YSTEM

 

 

This  Specification  governs  the  procedures  for  documentation  and  approval  of  all  materials  and 
equipment proposed for use in this Contract. All materials shall comply with the requirements of the 

Department of Transport ITS Design Manual

, Abu Dhabi 

Traffic Signals and Electronic Warning and 

Information Manual

 as directed by the Engineer. 

Subcontractor shall be responsible for the availability of the  ITS equipment  and to ensure that all 
equipment  shall  be  in  strict  adherence  to  the  Standard  Specification,  Particular  Specifications, 
Contract plans, and approved shop drawings. 

All costs of work and materials required for satisfying these specifications shall be included in the 
Bill of Quantities under which the ITS works and material equipment shall be paid, and no additional 
compensation will be allowed for the Subcontractor for any incidental costs that may occur in fulfilling 
the requirements of the Contract Documents. 

9.6.2.2 

Submittals 

All of the submittals in this section must be submitted as soon as possible after the award of Contract 
and  before  any  work  is  performed.  Subcontractor  shall  submit  the  following  for  approval  by  the 
Engineer: 

1.  System  and  equipment  design:    Contractor  shall  be  responsible  for  final  system  and 

equipment design. In accordance with the Project schedule, the Subcontractor shall produce 
a system design document (SDD) within 90 days from Project commencement date, which 
details  the  hardware  and  software  configuration  of  all  equipment  items,  provide  interface 
control  details,  and  documents  compliance  with  the  detailed  system  requirements  as 
provided  in  these  Specifications,  as  shown  on  the  Contract  plans  and  required  in  the 
Particular  Specifications.  SDD  should  include  presentation  of  all  supplied  systems 
requirements,  and  comply  with  the  following  requirements:  Subcontractor  shall  supply  a 
complete list of the make and model of all equipment detailed in the SDD.  All the equipment 
types that cannot be specified at the completion of the SDD, shall be listed and submitted 
with the SDD. If more than one type is to be considered, all proposed types shall be submitted 
with their evaluation criteria and compliance to the Specifications. 

2.  SDD  shall  contain  the  concept  of  operation,  the  communications  scheme,  and  the  major 

features of the proposed systems in comparison to the Specifications. Subcontractor shall 
not proceed with work until this document has been approved by the Engineer. Following the 
Owners review of the SDD the Subcontractor shall conduct a presentation of the SDD within 
45 days of the Owners review or as required by the Engineer. Presentation shall be held at 
the Owners premises at time and location as directed by the Engineer, and conducted by the 
senior  engineering  personnel  responsible  for  its  preparation  of  the  SDD.  Purpose  of  this 
review will be to permit the Owner and the Engineer to assess conformance of design details 
with the Specifications, in order that any deviations can be detected and corrected. SDD will 
form  the  basis  on  which  detailed  work  can  proceed.  Subcontractor  shall  not,  without  the 
specific approval in writing by the Engineer, submit materials or shop drawings for approval, 
place any material or equipment on order, commence manufacture of any items of plant, nor 
develop software until the Engineer has approved the SDD.   SDD shall serve as the basis 
for the system development. 

3.  SDD shall be accompanied by appropriate system hardware and software documentation, 

including  integrated  user  manuals,  laptop  screen  shots,  and  a  final  Interface  control 
document defining the data structure, meta data, latency, relevant object definition remote 
process  calls,  and  performance  characteristics  associated  with  each  of  the  systems. 
Subcontractor  shall  include  a  matrix  with  references  demonstrating  compliance  with  the 
Specifications; and any deviations shall be explicitly noted. 

Engineer’s approval of the SDD 

and any directions to revise the SDD will be submitted to the Subcontractor in writing.  Any 
oral directions received by the SDD will not be considered valid. 

4.  Should the Subcontractor wish to modify the approved SDD, he shall submit the changes or 

additions  to the  Engineer  for  approval.  Subcontractor  shall  not  implement  any  changes  or 
additions until approval has been received. SDD shall be updated regularly to reflect changes 
agreed with the Engineer, as the project proceeds. 

S

YSTEM

 

 

5.  Integration  staging  plan:    Subcontractors  proposed  integration  staging  plan  shall  be 

submitted at the  same time as SDD and it shall contain a detailed listing of the order and 
schedule for the installation and the testing of outstation and in station equipment. Staging 
plan shall clearly show the Subc

ontractor’s proposed order of field site installation and site 

acceptance testing and shall show when the central control equipment of the system is to be 
installed and tested and made operational. 

9.6.2.3 

Video Surveillance System (VSS) 

a.  Digital Video Management System (DVMS) 

If a DVMS is required for the Contract, the Subcontractor shall supply, install, configure, and test the 
DVMS, including the head-end server that is compatible with any systems currently implemented by 
the  Owner  in  the  traffic  control  centre.      On  completion  of  the  installation  and  connection  of  new 
cameras, and taking into account all existing and planned cameras, the DVMS shall have 25 % spare 
capacity for additional cameras.  DVMS shall comply with the requirements of the Abu Dhabi 

Traffic 

Signals and Electronic Warning and Information Manual

.   

The DVMS shall provide video surveillance management, video distribution within the Traffic Control 
Centre/Control Room, to the video walls and workstations, and to external stakeholders as directed 
by the Engineer and approved by the Owner.  

The DVMS shall manage the storage, retrieval, and provide for processing of the video. The DVMS 
shall  be  an  IP  network  based,  open  platform,  fully  distributed  digital  video  system  which  shall 
integrate different brands of cameras as directed by the Engineer. The DVMS shall utilize local area 
networks (LAN) as a transmission medium for video, configuration, as well as storage of all data. 
The DVMS shall provide full video control of all connected cameras and shall be able to interface 
with the existing DVMS at the existing control room locations, with additional full selection capability 
at any point within the network from a workstation or a video wall display.  

b.  Digital Video Storage System (DVSS) 

If a DVSS is required for the Contract, the Subcontractor shall supply, install, configure, and test a 
DVSS, including server, that is compatible with any systems currently implemented by the Owner in 
the traffic control centre. DVSS shall be integrated with the video surveillance system to record and 
store video streams via an Ethernet network. DVSS shall comply with the requirements of the Abu 
Dhabi 

Traffic Signals and Electronic Warning and Information Manual

.   

DVSS  shall  be  compatible  with  the  proposed  DVMS  and  all  other  video  surveillance  system  and 
video analytics system hardware and software.  

DVSS shall be configured to record video from the DVMS channels at 25 frames per second per 
video, at 4CIF and megapixel resolutions using MPEG4 and H.264 compression for a minimum of 
90 continuous days and archiving for the triggered events for one year. Compression factor shall not 
exceed 30 % and shall not compromise the video quality in any way. Storage system shall be sized 
based on the expected video stream bandwidth for H.264 video, at full resolution (D1) and full frame 
rate (25 fps) of a scene with high level of change (roadway).  

c.  Network PTZ Camera Assembly 

Network  camera  shall  be  a  domed,  compact,  day/night  within  a  rugged  enclosure  unless 
otherwise  authorized  by  the  Engineer.  All  circuits  shall  be  totally  solid  state  with  silicon 
transistors and integrated circuits. All modules shall be plug-in type. Part adjustments, and 
test point circuit symbols shall be silk-screened on the circuit boards for easy identification. 
Markings shall be in English and Arabic language. Back box of the camera unit shall have 
built-in memory to store camera and location specific dome settings, including labels, presets, 
patterns, and zones. These settings shall be automatically downloaded when a new dome 
drive is installed. 

S

YSTEM

 

 

Camera shall have a built-in 100 Base-TX network interface for live video streaming to any network 
application as approved by the Engineer. Cameras shall be equipped with SFP port. Type of each 
camera port/communication module (100TX or 100 FX) shall be chosen as per the site condition, 
camera position and as directed by the Engineer to reduce the requirement for the media converters. 
The communication modules shall be considered as a part of the camera. Dome system shall also 
feature open architecture connectivity for third-party software recording solutions allowing integration 
into any IP-based system, and allowing the system to record, manage, configure, and view multiple 
live streams. Network camera shall automatically adjust for optimized image quality and bandwidth 
efficiency  and  shall  allow  viewing  and  control  of  network  IP  video  by  users  with  the  appropriate 
permissions. Network dome camera shall consist of a black box, a dome drive, and a lower dome. 
Dome  drive  shall  feature  low  light  technology  allowing  the  camera  to  operate  in  scenes  where 
minimal light is present. Camera shall automatically compensate for scenes where large contrasts 
in  lighting  are  present.  Electronic  image  stabilization  shall  digitally  reduce  blurring  of  the  camera 
images due to vibration. 

Video shall comply with the following requirements: 

1. 

Digital compression: MJPEG, H.264 (MPEG-4 Part 10) 

2. 

Video streams: 3, simultaneous 

3. 

Video resolutions: 

 

i. 

PAL 

ii. 

4CIF  

iii. 

2CIF  

iv. 

CIF  

4. 

Frame rate  

i. 

H.264 at least 25 fps per port 

ii. 

MJPEG at least 25 fps per port. 

5. 

Web user interface: HTTP 

6. 

Progressive scan  

7. 

Wide dynamic range 

8. 

Supported  protocols:  IPv4/v6,  HTTP,  QoS,  FTP,  SMTP,  UPnP,  TCP,  UDP,  IGMP,  RTP, 

 

ICMP, DHCP, ARP, unicast IGMP, multicast IGMP, DNS, NTP 

9. 

Electronic image stabilization 

Dome drive features shall comply with the following: 

1. 

Image enhancement 

2. 

On-screen compass, tilt, and zoom display 

3. 

Password protection 

4. 

Rotating discreet liner with sealed fixed bubble 

5. 

Masking zones (programmable in size) shall be able to be labelled. 

6. 

Proportional pan/tilt: Continually decreases pan/tilt speeds in proportion to depth of zoom 

7. 

Variable scan speed: Scan speed shall be programmable from 1-40°/sec or greater 

8. 

 

“Auto flip” shall rotate dome 180° at bottom of tilt travel 

9. 

Programmable zoom speeds 

10. 

Freeze frame during presets  

11. 

Full 360 degrees continuous camera rotation with auto flip features. 

12. 

Minimum of 99 preset positions. 

S

YSTEM

 

 

13. 

Equipped with heater/blower 

14. 

Sensitivity of less than 0.01 lux for 30 IRE (B/W) and less than 0.1 lux for 30 IRE (colour). 

15. 

White balance of at least 10,000 K for MJPEG and H.264. 

16. 

Automatic video focus. 

17. 

Minimum 35 x optical, 12 x electronic zoom. 

18. 

Video buffer of at least 36 MB (pre-and post alarm)  

19. 

Electronic image stabilization 

20. 

Freeze frame during presets 

21. 

4 alarm inputs, and 4 outputs.  

22. 

Internal scheduling clock 

Mechanical (dome drive only) shall comply with the following: 

1. 

Pan movement 360° continuous pan rotation 

2. 

Manual pan/tilt speeds 

i. 

Pan 0.1° to 80°/sec or greater under manual operation, 

ii. 

150°/sec turbo tilt 0.1° to 40°/sec or greater under manual operation  

3. 

Automatic preset speeds 

i. 

Pan 400°/sec or greater 

ii. 

Tilt 200°/sec or greater 

Electrical shall comply with the followings: 

1. 

Input voltage: 18 to 30 VAC; 24 VAC nominal.  

2. 

Input power: less than 100 Watts, Fuse 4.5 A at rated voltage 

3. 

Power supply: 220 VAC fused with 1.5 A fuse (shall comply with reliability requirements) 

Reliability requirements shall meet the following: 

1. 

Environmental design requirements: Equipment shall meet all of its specified requirements 

 

during and after subjecting it to any combination of the following requirements: 

i. 

Mean time between Failures (MTBF) shall not be less than 100,000 hours. 

ii. 

Ambient temperature range of -10

o

to 60

o

C. 

iii. 

Relative humidity from 0 % to 95 % non-condensing. 

Camera control software shall comply with the following: 

1.  Pan and tilt system shall include a preset position controller which, upon reception of control 

signals from the control centre, shall automatically preset pan/tilt position, zoom and focus of 
the lens. A minimum of 99 preset positions shall be provided for each camera. In addition, 
each preset shall have its own title of up to 20 alphanumeric characters. 

2.  Each camera shall be capable of responding to pre-programmed tours of multiple sequential 

presets. Events that may be programmed as steps in a tour include preset positions, alarm 
acknowledgment,  alarm  or  preset  dwell  periods,  auxiliary  activation,  repeating  the  tour  or 
calling up another tour (chaining tours). 

3.  Pan  and tilt  controller  shall  be  operable from  the  surveillance  workstations'  graphical  user 

interface and/or a joystick keypad at the control centre. Acceleration of camera motion shall 
be proportional to joystick displacement from a central software-defined dead zone. 

Video delay: Video delay from the camera imager in the field to the operator monitor in the operations 
room shall not exceed 150 ms. Control loop delay from the original camera image to a control action 
by an operator to the time the image changes as a result shall not exceed 300 ms. 

S

YSTEM

 

 

Mediation of video permissions: All video images shall be titled with the organization, ID and priority 
level of the operator observing the image. Other operators requesting control of the camera from the 
operator  with  current  control  privileges  shall  have  their  priority  compared  to  that  of  the  current 
operator.  Control  shall  be  automatically  assigned  to  the  operator  with  highest  priority,  and  that 
operator's organization and priority level will then be titled on the video image. Priorities within an 
organization shall be event dependent to avoid inappropriate assignments. Organizations shall be 
the Owner and other agencies as may be directed by the Engineer. 

Panning, tilting, zooming and iris control shall be smooth and rapid, whether automatic or manual. 
Focus shall be automatic.  Colour camera shall be sensitive to low levels of  illumination and shall 
have  many  presets  to  which  it  can  return  with  high  accuracy.  Camera  assembly  shall  include  a 
camera controller and a communications interface. Dome enclosure shall be weatherproof to keep 
out moisture and dust. 

Zoom lens:  Each VSS field subsystem camera shall be equipped with a remotely controlled, variable 
focus, motorized zoom lens. The iris shall have an automatic control. The lens shall have a flat field 
with high resolution. An adjustable lens adapter ring shall be used to provide focus tracking. 

Environmental  housing:  Housing  shall  be  aesthetic  to  view,  compact,  vandal-proof,  rugged  and 
environmentally resistant. It shall be moisture, salt, sand and dust proof and suitable for operation in 
a hot and humid atmosphere. It shall be manufactured of polymer technology for rigidity and long 
service life. Housing shall have weather-resistant cable connectors as required for video, power and 
remote controls. Housings shall consist of a double upper shell and a double lower viewing dome. 
Housing shall be equipped with a heater and a blower that are controlled by a thermostat to maintain 
an optimum environment within the housing. Housing shall comply with IP-66 standards. 

d.  Camera Coaxial Cable 

All outdoor coaxial cables shall be of 75-ohm RG-6/U type. Centre conductor shall be an 18 AWG 
100 % solid bare copper (BC) conductor. Shield shall be 100 % tinned copper, braided, and shall 
provide 95 % efficiency, minimum. Outer jacket shall be black PVC. Cable shall have maximum 2.4 
dB per 100 m attenuation at 10 MHz. Nominal capacitance shall be 53 pf per m. Nominal velocity of 
propagation shall be 82 %., Nominal impedance shall be 75 ohms. Coaxial cable shall be terminated 
with 75-ohm BNC nickel-plated connectors with 50 microns gold plated centre contacts. 

All indoor video termination applications shall use a subminiature RG-59/U type, having 1 coax, 25 
AWG,  stranded  (19x37)  BC  -  bare  copper  conductors,  foam  PE-gas  injected  foam  polyethylene 
insulation, aluminium foil-polyester tape-aluminium foil (Duofoil) shield with 100 % shield coverage 
plus tinned copper braid shield with 95 % shield coverage. Nominal capacitance shall be 16.3 pf per 
300 mm, the nominal velocity of propagation shall be 83 %, and the nominal impedance shall be 75 
ohms. 

e.  Camera Control Cable 

If used in this Contract, all control cables shall be 2-pair, STP, tinned stranded copper conductors 
with aluminium/polyester shield, 100 % coverage and S-R PVC jacket. 

1.  Hybrid Cable 

Proposed hybrid cable by the Subcontractor shall meet most of the Specifications of the video coaxial 
cable, control cable and power cable, as approved by the Engineer. This cable shall be capable to 
transmit the control and video signals and also to feed the camera with power at the same time using 
the same hybrid cable. Proposed cable shall be sufficient for outdoor use and shall be provided by 
a recognized manufacturer in cabling industry. Outer jacket shall be black PVC. Cables shall comply 
with the following specifications and requirements: 

i. 

Video cable shall be 75-ohm RG-6/U type and as follows: 

a)  Conductor: Single bare copper  
b)  Conductor diameter: 1.02 mm 
c)  Insulation dia (±0.15 mm): 4.6 mm 

S

YSTEM

 

 

d)  Shield: Al-Pet- Al shield > 125 % 
e)  Braiding layer: Tinned copper 
f)  Braiding coverage: 95 %  
g)  Outer jacket: LSZH  
h)  Jacket colour: Black  
i)  Jacket diameter (± 0.20 mm):6.6 mm  

ii. 

Power cable will be 3 core @ AWG 18 and as follows: 

a)  Conductor: 3X bare copper 
b)  Conductor diameter:1.22 mm 
c)  Insulation dia (±0.10 mm):1.6 x 3C twist  
d)  Voltage rating 300V 
e)  Voltage drop for 20 m @ 24 V dc: 0.61 V dc 
f)  Outer jacket: LSZH  
g)  Jacket colour: Grey 
h)  Jacket diameter (± 0.15 mm):4.1 mm  

iii. 

Control cable will be twisted pair STP and as follows: 

a)  Conductor: Stranded tinned copper 
b)  Conductor size: AWG 22 
c)  Conductor diameter: 0.77 mm 
d)  Insulation dia: (±0.01 mm)1.2 x 2C  twist 
e)  Shield: Al-Pet-Al shield ( on each pair) > 115% 
f)  Outer jacket: LSZH 
g)  Jacket diameter: 3.8 mm 
h)  Jacket colour: Grey 

iv. 

Characteristics as follows: 

a)  6+PE 
b)  Current carrying capacity: 13 A at 55

o

 C 

c)  Operating temperature -40

o

 C, +125

o

 C 

d)  Gold plated contacts  

9.6.2.4 

Vehicle Detection System 

Subcontractor shall furnish, install, integrate, configure, and test a vehicle detection system (VDS), 
including  the  head-end  server,  for  the  purpose  of  obtaining  traffic  data  and  possible  use  in  other 
subsystems.  VDS shall comply with the requirements of the Abu Dhabi 

Traffic Signals and Electronic 

Warning and Information Manual

.   

a.  Microwave / Radar Vehicle Detector  

Owner prefers a road vehicle detector system (RVDS) that is a non-loop based and non-intrusive 
such  as  radar  and video,  but  will  consider  alternate  vehicle  detection  solutions,  provided  that  the 
achieved accuracy meets the requirements of the RVDS specified herein, and the Abu Dhabi 

Traffic 

Signals and Electronic Warning and Information Manual

.   

When required in the Contract Documents, the Subcontractor shall supply and install a RVDS for 
the purpose of obtaining traffic data and possible use in other subsystems.  RVDS shall comply with 
the requirements of the Abu Dhabi 

Traffic Signals and Electronic Warning and Information Manual

.   

b.  Field Equipment 

Subcontractor  shall  furnish,  install,  integrate,  configure,  and  test  vehicle  detection  equipment  in 
accordance with the following: 

1.  Capabilities: System shall provide counts, speeds, occupancy, queue and classification data 

at per-lane and aggregate basis. Candidate technologies are: 

i. 

Inductive loop detectors (least preferred).  

ii. 

Video vehicle detection.  

iii. 

Radar vehicle detection.  

iv. 

Laser vehicle detection.  

S

YSTEM

 

 

v. 

Any other Owner or Engineer approved method 

2.  Accuracy requirements. Following accuracy criteria shall apply: 

i. 

Self-calibration (count and occupancy). The system shall be able to achieve 85 % or 
higher accuracy for vehicle counts and lane occupancy for each lane.  

ii. 

Manual  calibration  (count  and  occupancy).  System  shall  be  able  to  achieve  via 
manual tuning accuracy of 95 % or more for count and occupancy on a per-lane basis 
when measured against ground truth. 

iii. 

Speed. System shall be able to achieve 90 % or higher speed measurement accuracy 
when compared to ground truth. 

All field equipment shall utilize IP network for communication to the  traffic management centre  or 
local control room as approved by the Engineer.   

All RVDS equipment shall be installed on poles along the roadway, embedded in pavement or on 
attached to the sign gantries. Use of multi-purpose poles is encouraged to reduce the total number 
of poles/structures; however such use is acceptable only if it does not in any way compromise the 
operation of the collocated systems. If a separate structure is used it shall be suitable for the size of 
the  provided  equipment  and  shall  be  capable  of  supporting  all  required  equipment  plus  50  % 
increase in equipment weight with an appropriate safety factor. 

c.  Vehicle Detector Pole and Foundation  

 Pole foundations shall be consistent with the manufacturing requirements, and shall comply with 
theses Specifications and the Contract plans. RVDS detectors shall be mounted on poles or other 
structures  of  sufficient  height  and  of  construction  similar  to  that  Specified  elsewhere  for  video 
surveillance  camera  poles.  Mounting  systems  provided  by  the  system  manufacturer  shall  be 
preferred.  

9.6.2.5 

Traveller Information System (TIS) 

Subcontractor  shall  furnish,  install,  integrate,  configure,  and  test  a  TIS,  including  the  head-end 
server, as indicated on the Contract plans, specified herein, and in accordance with the requirements 
of the Abu Dhabi 

Traffic Signals and Electronic Warning and Information Manual

, as approved by 

the Engineer. TIS includes dynamic message signs, directional electronic devices including lane and 
speed control signs, and the subset of variable message signs mounted on the gantry, pole, and 
other  similar  structures  for  queue  warning,  travel  time  purposes etc.   Signs  shall  comply  with the 
applicable requirements of BS EN 12966. 

a.  Field Equipment 

General requirements shall be as follows:  

1.  All dynamic message signs (DMS) shall be full-colour graphic matrix type, regardless of their 

intended use. Minimum dimensions for the DMS signs shall be as follows: 

i. 

Full Size DMS signs shall have minimum dimensions of 6000 x 2000 mm (Type A2) 
for major roadways and 9000 x 3000 mm (Type A1) for major roadways with more 
than four lanes of transportation. Full DMS signs shall have minimum dimensions of 
4000 x 2000 mm (Type A4) for all secondary roadways. For all locations where the 
transportation envelope may be restricted the minimum dimensions of the signs shall 
be 6000 x 900 mm or 9000 x 900 mm if there are four or more lanes of Transportation.  

ii. 

Full size DMS signs shall provide critical information to drivers in English and Arabic 
and shall be able to contain graphic symbols. Minimum size of displayed characters 
shall be sufficient to allow the characters to be easily discernable (5 minutes of arc) 
from a distance of at least 300 m by an operator having the lowest visual acuity which 
allows the operator to legally operate a vehicle in the area. 

2.  Travel time (TT) signs shall be used to display point-to-point travel time information. These 

signs shall be mounted on the side of the roadway. These signs may be either fixed signs 
with  a  full  colour  graphic  matrix  DMS  insert  or  full  colour  graphic  matrix  DMS  signs  as 
approved by the Engineer and approved by the Owner. Minimum size of TT Signs shall be 

S

YSTEM

 

 

4000 x 2000 mm. The same character size rules applicable to the full DMS signs shall apply. 
All locations shall have one (1) travel time sign on each side of the carriageway. 

3.  Queue  warning  /travel  time  DMS  (Type  A3)  shall  be  used  to  provide  point-to-point  travel 

information and other travel related information on the  lane control and speed control sign 
gantries (such as queue information). Signs are overhead mounted and shall be full colour 
graphic matrix signs. The minimum size of these signs shall be 2000 x 2000 mm. The same 
character size rules applicable to the full DMS shall apply. 

4.  Lane  control  and  speed  control  signs  (LCSCS)  shall  be  used  to  provide  lane  and  speed 

control.  All  LCSCS  shall  be  full  colour  graphic  matrix  signs  with  ability  to  display  required 
graphic  images.  LCSCS  may  be  single  signs  (preferred)  or  two  separate  signs  (one  lane 
control sign and one speed control sign). Minimum dimensions for LCSCS signs shall be 900 
x 900 mm. 

5.  All provided signs shall be produced by a single manufacturer who shall be approved by the 

Owner and/or the Engineer. 

6.  Refer to the Department  of Transport ITS Design Manual regarding the DMS and LCSCS 

gantry types: 

i. 

6 lane and 4 lane type gantries with cladding 

ii. 

6 lane and 4 lane standard truss type gantry 

iii. 

6 lane and 4 lane standard monotube type gantry 

 
DMS display technology shall comply with the following: 

1.  Sign shall be light emitting diode (LED) technology based with full graphics display and shall 

be capable of displaying both English and Arabic alphanumeric characters as well as custom 
characters and symbols of various sizes.  

2.  European  Norms,  EN  12966  defines  several  optical  parameters  to  evaluate  DMS  optical 

performance.  Each  optical  parameter  is  associated  with  a  class  of  performance.  These 
parameters are luminance, luminance ratio, beam width, and colour coordinates. 

3.  The display shall be a full graphics matrix display meeting the following requirements: 

i. 

LEDs per pixel 

– 3 blue, red, and green LED (minimum).  

ii. 

Visual height of display 

– As specified herein this Specification. 

iii. 

Visual length of display 

– As specified herein this Specification 

iv. 

Number of colours per pixel 

–equivalent to 16 levels for each main colour. 

v. 

Time to switch between different sign aspects and displays shall not exceed 1.0 
second. This time is defined as the delay between sign controller’s reception of 
a valid signal and complete display of the aspect. 

4.  Dot  pitch  shall  be  fully  compliant  with  BS  EN  12966,  Annex  C  graphics  requirements,  as 

approved by the Engineer. Dot pitch shall produce luminance L3 and a luminance ratio equal 
or better than R2 as per BS EN 12966. 

 

LCSC display technology shall comply with the following:  

1.  Sign shall be LED technology based with graphics display and shall be capable of displaying 

both  numbers  and  custom  characters  and  symbols  of  various  sizes.  Changing  from  one 
message to another shall be instantaneous without visual disturbance. Visual uniformity of 
LED  colour(s)  across  the  entire  display  shall  be  ensured  and  no  visible  difference  in  the 
luminous intensity of any pixel in the display at any luminance level for a given colour shall 
be noticeable. Display shall meet the following requirements: 

i. 

Visual height of display 

– As shown on the Contract plans but shall not be less Than 

850 mm unless otherwise approved by the Engineer. 

S

YSTEM

 

 

ii. 

Visual length of display 

– As shown on the Contract plans but shall not be less than 

850 mm unless otherwise approved by the Engineer. 

iii. 

Enclosure front size 

– 1000 x1000 mm unless otherwise shown on the Contract plans 

unless otherwise approved by the Engineer. 

iv. 

Time  to  switch  between  different  sign  aspects  and  displays  shall  not  exceed  1.0 
second. 

2.  All  LEDs  of  the  same  colour  proposed for  use  in  the  sign  shall  come from the  same  LED 

component  manufacturer's  bin  and  have  the  same  component  reference  for  LED's  of  the 
same type. The subcontractor shall submit written assurances and an explanatory document 
from  the  manufacturer  that  such  requirements  can  be  met.  The  written  assurances  and 
explanatory document shall be included with the material submittal. 

3.  LCSC  dot  pitch  definitions  shall  comply  with  BS  EN12966,  Annex  C  requirements,  as 

approved by the Engineer. 

Subcontractor  shall  furnish  and  install  queue  warning/travel  time  DMS  on  the  LCSCS 
gantries. These signs are overhead mounted and shall be full  colour graphic matrix signs. 
The minimum size of these signs shall be 2000 x 2000 mm. DMS shall comply with the same 
requirements applicable to the full DMS. 

Subcontractor shall furnish and install travel time signs as shown in the Contract plans. These 
signs shall be mounted on the side and median of the roadway as indicated in the Contract 
plans. These signs are fixed traffic signs with a full colour graphic DMS inserts. Minimum size 
of  the  travel  time  signs  shall  be  4000  x  4000  mm.  DMS  inserts  shall  comply  with  the 
applicable requirements of the full DMS signs. All locations shall have one travel time sign 
on each side of the road as indicated in the Contract plans. 

DMS and LCSC shall be compatible with BS EN12966, CE or equivalent specifications as 
certified  by  a  governmental  body  and  as  approved  by  the  Engineer.  As  a  minimum,  the 
certification shall apply to the design, fabrication, and maintenance of the LED DMS/LCSCS.  

Enclosure designs shall comply with the following: 

1.  Structure of the DMS and LCSCS housings shall be IP55 rated or better for the housing, and 

IP54  or  better  for  the  ventilation  openings.  Structure  shall  be  weatherproof  and  corrosion 
resistant.  Signs  shall  comply  with  BS  EN12966,  Class  T2  requirements  for  resistance  to 
temperature change. Control cabinets shall be rated for IP56 protection. 

2.  Enclosures  shall  be  fully  welded  to  protected  against  the  entry  of  dust,  dirt,  water  and 

undesirable  elements  and  shall  be  manufactured  in  rust  resistant  aluminium  and/or 
aluminium  alloy  corresponding  to  European  Aluminium  Standards,  EN  AW  1050,  EN  AW 
6063, EN AW 6005 A and/or EN AW 6060 materials and grades. 

3.  For  overall  weight  consideration  steel  enclosures  of  any  type  shall  not  be  considered  for 

designing the DMS enclosure unless otherwise approved by the Engineer. Mass of the DMS 
and enclosure shall not exceed 2,300 kg. 

4.  Enclosure  shall  be  resistant  to  WL7  class  wind  pressure  (1.4  kN/m2)  and  TDB2  class 

temporary deflection (5 mm.m-1). Subcontractor shall furnish evidence of compliance such 
as BS EN 12899 certification in this regard. 

5.  DMS and LCSC power supplies shall be 220 V AC, 50 Hz with AC/DC converter as per sign 

manufacturer  requirements.  DMS  enclosure  shall  contain  at  least  2  of  16  Amp  220  V  AC 
power outlet receptacles and one 100 W fire rated light source for maintenance purposes. 
LCSC  enclosures  shall  contain  a  13  Amp  220  V  AC  power  receptacles  for  maintenance 
purposes. Maximum power consumption used by the DMS including fans and controller shall 
not exceed 3 kW.  

6.  Front Face of enclosures and front protective grids shall be protected by a flat, resistant and 

profoundly black finish. Paint quality shall comply with ISO 9227 500 hours salt spray test 
Gt0 value. 

S

YSTEM

 

 

Display visibility and viewing angle: DMS and LCSC visibility angle (visual angularity), known as 
“beam width”, B4 in BS EN 12966 shall be 20o minimum (±10 horizontal, 10 vertical). Face of  
the signs shall be capable of being inclined or declined from the vertical following installation on 
site by a minimum of 3o for DMS and 5o for LCSCS, and shall be adjusted as necessary to suit 
site conditions to optimize viewing by approaching vehicles as approved by the Engineer. 

Luminance control: Sign contrast values shall be compliant with BS EN 12966 standard Class 
R2 or R3 for appropriate installation conditions. DMS luminance values shall meet at least  BS 
EN12966 class L3 luminance level requirements. All LED colours intensity shall comply with BS 
EN 12966 class C2 standards as approved by the Engineer.  

Communications:  DMS  and  LCSC  shall  communicate  with  the  central  control  unit  via  the 
communication  system  architecture.  Compliance  with  the  latest  version  of  applicable  NTCIP 
communication  protocols  is  required  and  shall  be  used  in  this  Contract  in  addition  to  other 
communications  protocols  as  approved  by  the  Engineer.  As  a  minimum,  IP  over  100  Mbps 
Ethernet  communications  shall  be  provided  as  part  of  the  DMS  and  LCSC  communication 
protocols. 

b.  Installation of Dynamic Message Signs 

Outdoor dynamic  message signs (DMS), including travel time, lane control and speed control 
signs (LCSCS) shall be mounted on an overhead support structure as per the site conditions, at 
location shown on the Contract plans, and as approved by the Engineer. Where applicable the 
LCSCS  shall  be  mounted  on  special  mounting  structures  as  per  the  site  conditions  and  as 
approved by the Engineer. 

Service platform (catwalk) between supports for the DMS shall be from end to end,  and shall 
have easy access by service ladder attached to the upstream side of the structure of the road 
side gantry.  

Subcontractor  shall  conduct  the  detailed  design  of  the  DMS  and  LCSCS  mounting  structure, 
mounting  structure  foundation,  and  the  sign  mounting  details  in  accordance  with  the  sign 
manufacturer requirements, the sign installation site details, and as approved by the Engineer. 

Subcontractor  shall  submit  to  the  Engineer  for  review  and  approval  sign  mounting  details, 
mounting structure foundation details, structural analysis calculations, and vibration analysis of 
the mounting structure as per each site and sign specific requirements and in accordance with 
sign  manufacturer  recommendations  prior  to  installing  the  mounting  structure.  All  mounting 
structures shall be made from hot dip galvanized steel or from stainless steel. All drawings and 
calculations of the sign mounting structure as well as its proposed materials and components 
shall  be  submitted  to  the  Engineer  for  approval  prior  to  commencing  any  manufacturing  or 
construction work on the structure. 

An analysis shall be submitted to the Engineer for approval prior to manufacturing of the sign 
mounting structure, and include the following: 

1.  Overall analysis of structure as per BS EN 12899. 

2.  Vibration analysis of gantry structure as per BS EN 12966.  

3.  Wind resistance analysis according to 120 km/h wind load.  

4.  Seismic analysis of structure according to UBC 97  

5.  Analysis of welding points and their thicknesses  

6.  Analysis of bolts and screws located at main joints of structure  

7.  Fatigue analysis of welding, bolts and nuts and overall gantry structure for a 15 year DMS 

and LCSCS system life. 

All outer parts of frame shall be aluminium, stainless steel, or as approved by the Engineer. All gantry 
structures shall have cladding as shown on the Contract plans. Cladding, colour, pattern, size and 

S

YSTEM

 

 

materials if it is part of the structure, shall be as approved by the Engineer. Paint shall be UV resistant 
and certified by an independent laboratory according to ISO 9227, 500 hours salt spray test as Gt0. 

All fasteners, screws, nuts, bolts and washers etc. used in the gantry frame and cladding shall be 
provided in stainless steel or suitable nonferrous A4 quality material. 

Subcontractor  shall  conduct  all  subsurface  geotechnical  borings  for  each  DMS/LCSCS  sign  final 
location  to  determine  soil  features  used  in  conjunction  with  sign  mounting  structure  foundation 
designs. The findings shall be submitted to the Engineer for review and approval. 

If  requested  by  the  Engineer  and  depending  on  the  exact  location  details  of  each  sign,  the 
Subcontractor  shall  ensure  that  the  gantry  or  cantilever  design  has  a  vertical  angle  adjustment 
mechanism adequate to adapt the DMS/LCSCS to the local roadway geometry. 

Gantry height at the lowest point of arms shall not be less than 6.5 m, or as indicated on the Contract 
plans, as approved by the Engineer.  

Projecting portion of the foundation anchor bolts and the nut and washer shall be treated by hot dip 
galvanizing. 

All anchor bolts, ground rods and PVC raceways or conduits shall be located securely in position by 
the use of templates during the placing of foundation concrete. 

Once  the  DMS/LCSCS  is  installed,  several  types  of  civil  works  may  be  required  by  the  main 
Contractor to remediate any disturbance to the DMS installation site, as approved by the Engineer. 
These include, but not by way of limitation, site grading, landscaping and planting, and/or concreting. 

c.  Portable Variable Message Signs 

Contractor  shall  provide  and  install  portable  variable  message  signs  (PVMS)  as  part  of  his 
maintenance  of  traffic  requirements  (per  Section  1.19.14,  Traffic  control,  detour  schemes  and 
pedestrian safety, of Chapter 1) to warn drivers about construction and construction detours ahead. 
Display area of the PVMS shall be 3 m² (usually sized 2 x 1.5 m) at least. Characters shall be 360 
mm high minimum. It shall have a high-resolution full graphic display with single colour and variable 
brightness  levels  with  low  energy  consumption  and  at  least  30°  wide  viewing  angle.  It  shall  have 
control options through a local keyboard, through cable and/or wireless LAN, or through GSM and 
modem remote control. It shall be solar powered with mandatory battery backup and with a local 
power source and generator source option. It shall have a minimum of 99 Arabic and English user-
programmable  and  pre-programmed  messages  and  pictograms,  with  all  international  traffic  signs 
graphically preloaded.  

PVMS shall be rugged, made of galvanized steel and easy to operate, maintain, and manoeuvre. 
Trailer  shall  have  a  proper  suspension  system,  parking  brake,  corrosion  protected  mechanical 
equipment, properly configured hydraulic mechanism, and an adjustable hook height for use with 
different types of puller vehicles. Battery and hydraulic boxes shall be of durable fabrication, lockable, 
hinged, ventilated, and mounted to the trailer frame to protect batteries and hydraulic components 
from weather and vandalism. Control box shall be of durable fabrication, lockable, hinged, ventilated, 
and mounted to the trailer frame to protect the instrument panel and electronic controls from weather 
and vandalism.  

PVMS shall not weigh more than 1,300 kg. Typical dimensions shall not exceed 5,500 x 1,750 mm. 

9.6.2.6 

Installation of Portable Variable Message Signs 

The Contractor shall furnish and install LED-based portable variable message signs (PVMS) during 
various stages of the project to alert drivers to construction activities and hazards. 

PVMS  shall  be  mounted  on  a  trailer  that  can  be  towed  and  placed  at  the  work  zone  location  as 
directed or approved by the Engineer. PVMS may be also known as mobile variable message signs, 
mobile  dynamic message  signs, trailer-mounted variable  message signs,  and  mobile  changeable 
message signs. 

S

YSTEM

 

 

The sign shall be equipped with an electro-hydraulic raising/lowering mechanism. A manual brake 
winch and pulley system shall also be provided for emergency cases. The sign shall be able to be 
securely locked either during transport or  in the display height position. The sign shall  be able to 
rotate and securely lock in any position. The sign height in the “raised” position shall not exceed 4m. 

The sign shall be delivered with a complete remote control system including, but not limited to, laptop, 
all required operation and maintenance manuals and software, as well as hands-on training for the 
operator.  The  PVMS  shall  be  equipped  with  a  GPS  system  to  confirm  its  location  to  the  project 
construction operations manager. 

The  PVMS  power  supply  shall  include  internal  sensing  capability  to  adjust  LED  brightness  in  all 
visibility conditions and times of the day. 

Lighting: A twofold halogen warning light system shall be attached to the top of the mobile advance 
digital board. 

Warning light shall have the following salient features: 

1.  Two (2) fold halogen warning lights in accordance with WL7, EN 12352 L9 350mm diameter 

lamps 

2.  Automatic day and night adjustment 

3.  12/24 Volt rechargeable battery power supply 

4.  The  two  fold  halogen  warning  light  system  shall  be  furnished  with rechargeable  batteries, 

12V, 230 Ah and an auto charger device for lead and lead gel accumulators, complete with 
replacement  bulbs,  lenses  and  other  associated  ancillary  items  to  ensure  continuous 
operation of the warning light system.   

9.6.2.7 

Overheight Vehicle Detection System 

Subcontractor shall deploy an overheight vehicle detection system (OHVDS) that provides detection 
of  overheight  vehicles  approaching  height-limited  structures,  as  shown  on  the  Contract  plans, 
required in the Particular Specifications and included in the Bills of Quantities. System shall be able 
to provide warning to operators of such vehicles, and to provide a safe exit from the roadway prior 
to the height-limited structure. In addition, the system shall detect and record violations and shall be 
able to implement secondary protection measures where necessary. Overheight vehicle detection 
system shall comply with the requirements of the Abu Dhabi 

Traffic Signals and Electronic Warning 

and Information Manual

Incident prevention shall function as follows: 

1.  OHVD  shall  detect  the  presence  of  an  over  height  vehicle  on  the  roadway  leading  to  the 

height-restricted area. Traffic control centre shall be notified electronically and immediately 
of the offending vehicle. 

2.  A combination of audible alarms, alternating variable message sign, flashers and a backlit 

warning  sign  shall  be  triggered  in  a  timely  manner  to  warn  the  driver  of  the  potentially 
hazardous vehicle and to provide directions for immediate route exits prior to impacting a low 
clearance overpass ahead. 

3.  If the offending vehicle continues to approach the height-restricted area past the initial OHVD 

detector, a second OHVD station shall report the threat instantly to the traffic control centre 
and shall deploy secondary protection measures if they are considered necessary 

a.  Field Equipment 

Alternate  detection technology  of  overheight  vehicles  (such  as  overhead  laser  scanners) may  be 
proposed by the Contractor for review.  Procurement or deployment of alternate detection devices 
or  system  shall  not  be  allowed  without  written  approval  by  the  Engineer.    Otherwise,  the 
Subcontractor shall comply with the requirements of this section. 

S

YSTEM

 

 

Subcontractor  shall  furnish,  install,  integrate,  configure,  and  test  an  overheight  vehicle  detection 
system with the following components: 

1.  Overheight vehicle detector system (including transmitter and receiver units with direction of 

travel determination capability). These shall be placed on opposite sides of the roadway for 
light beam emission. Detection of offending vehicles shall occur when the said beams are 
broken by an overheight vehicle. The OHVDS shall have built-in safeguards to minimize false 
alarms.  The detector shall include the following items: 

i. 

Sensor: Sensors shall be placed ahead of the warning sign at a sufficient distance 
to  allow  the  offending  driver  to  observe  the  sign  for  at  least  3  seconds  at  the 
maximum roadway speed. 

ii. 

Mounting:   OHVDS sensors and equipment enclosure shall be mounted on poles 
or other structures of sufficient height and of construction similar to that specified 
elsewhere  for  CCTV  poles.  Mounting  systems  provided  by  the  system 
manufacturer shall be preferred. 

iii. 

Foundations:    Pole  foundations  shall  be  consistent  with  manufacturing 
requirements and shall conform to these Specifications and Contract plans. 

2.  Variable  message  signs  (VMS) for  displaying  warnings  and  directions  to  motorists.  These 

shall be as specified herein these Specifications for the traveller information systems for Type 
4 DMS (4,000 mm x 2,000 mm). However, full range of capabilities shall not be required as 
directed  by  the  Engineer.  The  warning  VMS  signs  and  associated  gantry,  pole,  and 
foundations shall be compatible with the general VMS specifications given elsewhere in this 
specification with the following exceptions: 

i. 

Sign type: Sign shall be blankout type intended to display a single message.  As a 
result there is no requirement for full graphic matrix or for full colour. 

ii. 

Sign activation: Sign shall be activated automatically by OHVDS sensor. 

iii. 

Additional warning features: VMS sign shall be equipped with flashing strobes and 
beacons. 

3.  Alarm bell for audible warning shall have a parabolic shield for sound direction and reduction 

as necessary.  Bell shall provide sound output of 100 dB or higher at 3 m. Sound output to 
the sides and rear shall be reduced by the use of shield by at least 50 %. Equipment shall be 
compatible with mounting and power provided to the warning sign location. 

4.  Maximum  height  limit  and  high  vehicle  exit  sign  shall  comply  with the  requirements  of the 

Abu Dhabi Traffic Signals and Electronic Warning and Information Manual. Maximum height 
limit sign shall be placed ahead of the height-limited structure in a location which allows for 
a safe exit of an overheight vehicle. Sign shall be placed prior to the overheight vehicle exit 
at a distance sufficient to allow time for the offending vehicle to change lanes if necessary 
and take the provided exit. High vehicle exit sign shall contain audio and visual overheight 
indicators and provide a clear exit direction to motorists. Sign shall comply with the following 
items: 

i. 

Mounting:  Signs shall be mounted on poles or other structures of sufficient height 
and  of  construction  in  accordance  with  the  requirements  of  the  Department  of 
Transport Manual of Uniform Traffic Control Devices. Mounting systems provided 
by the system manufacturer shall be preferred. 

ii. 

Foundations:    Pole  foundations  shall  be  consistent  with  manufacturing 
requirements and shall conform to the Article 9.2.3.2 and the Contract plans. 

5.  Secondary protection devices shall be provided in cases where height restricted structure is 

sensitive and requires additional active protection measures as shown on the Contract plans, 
as required by the Particular Specifications and where included in the Bills of Quantities, as 
approved by the Engineer. 

9.6.2.8 

Roadway Weather Information System 

Subcontractor  shall  furnish,  install,  integrate,  configure,  and  test  a  roadway  weather  information 
system (RWIS), including the head-end server, for the purpose of monitoring roadway atmospheric 

S

YSTEM

 

 

and  pavement  environmental  conditions.  RWIS  shall  incorporate  continuous  monitoring  and 
measuring of air pollutants in accordance with the relevant authority. Subcontractor shall co-ordinate 
with the relevant authority about installing and operating weather stations. RWIS shall comply with 
the requirements of the Abu Dhabi 

Traffic Signals and Electronic Warning and Information Manual.

 

RWIS shall provide the following measurements as directed by the Engineer: 

1.  Air temperature (high / low / current) 
2.  Humidity  
3.  Solar radiation 
4.  Wind speed and direction (gusts and sustained) 
5.  Precipitation 
6.  Visibility 
7.  Fog detection 
8.  Noise measurement 
9.  Pavement condition 
10. Air quality 

– CO, NOx, H

2

S, CH

4

, HC, BETX, PM

10

, PM 

2.5

 

a.  Field Equipment  

RWIS  shall  include  a  sensor  tower  used  for  mounting  of  all  sensors,  video  surveillance 
camera,  local fence  and  equipment  enclosure,  local  data  logger  for  data  storage,  and the 
necessary site and traffic management centre/control room hardware and software to transfer 
the weather and air quality data to other agencies such as Environment Agency Abu Dhabi 
(EAD)  or  other  applicable  authority.  Weather  sensors  shall  be  placed  at  least  3  m  above 
ground for added security and protection against vandalism”.

 

b.  RWIS Tower and Foundation 

Each  weather  station  shall  be  provided  with  a  self  supporting tower,  including  foundation, 
which provides mounting space for the weather sensors, ground clearance to facilitate sensor 
accuracy, and some degree of physical security for the sensor equipment. Tower shall also 
provide mounting capability for the data logger/network interface equipment. 

Tower shall be designed to support the static load from the weather station equipment, and 
the dynamic load resulting from wind speeds of up to 120 km/hr. 

Subcontractor  shall  include  the  necessary  signal  and  power  conduits,  connections  to  backbone 
communications network, utility power connections, pole and tower foundations, guard rails, fencing, 
bollards,  etc  as  required  for  an  operation  roadway  weather  information  system  communications 
system 

c.  Communications Subsystem 

All  communications  for  the  RWIS  shall  be  primarily  based  on  a  single  mode  (SM)  fibre  optic 
backbone communications system. Communications system cables shall be routed from individual 
intersections  in  dedicated,  concrete  encased  conduits,  as  shown  on  the  Contract  plans  and  as 
approved by the Engineer. 

Communications backbone shall be compliant with communications industry international standards. 
As  a  minimum,  the  following  communications  interfaces  shall  be  provided,  including  PAL  video, 
10/100/1000 Mbps Ethernet, and low speed RS-232/422. 

In the case of Fiber Optics (FO) used, the Subcontractor shall install a backbone communications 
system based on active access nodes linked by optical fibres forming a reliable and redundant high 
speed medium for the transparent transport of voice, data, LAN and video services. 

As the transmission system will be used as a backbone network, the system shall have following 
characteristics: 

1.  High availability 
2.  High reliability 

 

 

 

 

 

 

 

Content      ..     51      52      53      54     ..