DLK-82 < DTC/CIRCUIT DIAGNOSIS > [WITH INTELLIGENT KEY SYSTEM] DOOR LOCK ACTUATOR Is the inspection result normal? YES >> GO TO 3. NO >> Repair or replace harness. 3. CHECK BCM OUTPUT SIGNAL 1. Connect BCM connector. 2. Check voltage between front door lock actuator RH harness connector and ground. Is the inspection result normal? YES >> Check for internal short of each door lock actuator. NO >> Replace BCM. Refer to BCS-69, "Removal and Installation" REAR LH INFOID:0000000009268760 1. CHECK FUNCTION 1. Select DOOR LOCK of BCM using CONSULT. 2. Select DOOR LOCK in ACTIVE TEST mode. 3. Touch ALL LOCK or ALL UNLK to check that it works normally. YES >> Door lock actuator is OK. NO >> Refer to DLK-83, "REAR RH : Diagnosis Procedure" . REAR LH : Diagnosis Procedure INFOID:0000000009268761 Regarding Wiring Diagram information, refer to DLK-50, "POWER DOOR LOCK SYSTEM : Wiring Diagram" . 1. CHECK DOOR LOCK ACTUATOR INPUT SIGNAL 1. Turn ignition switch OFF. 2. Disconnect rear door lock actuator LH connector. 3. Check voltage between rear door lock actuator LH harness connector and ground. Is the inspection result normal? YES >> Replace rear door lock actuator LH. NO >> GO TO 2. 2. CHECK DOOR LOCK ACTUATOR CIRCUIT 1. Disconnect BCM connector and all door lock actuator connectors. BCM Ground Continuity Connector Terminal M99 65 No 59 (+) (–) Condition Voltage (Approx.) BCM Connector Terminal M99 65 Ground Door lock and unlock switch Lock 12 V 59 Unlock (+) (–) Condition Voltage (Approx.) Rear door lock actuator LH Connector Terminal D205 1 Ground Door lock and unlock switch Lock 12 V 2 Unlock |