Symptom: *BOTH MIRRORS DO NOT UNFOLD EXCEPT WITH EITHER POSSIBLE CAUSES RELATED DIAGNOSTIC TROUBLE CODES POWER FOLDING MIRROR SWITCH FOLDING MIRROR SWITCH SIGNAL SHORT TO GROUND BODY CONTROL MODULE TEST ACTION APPLICABILITY 1 With the DRBIII t, read DTCs. Does the DRBIII t display any related DTC’s? All Yes → Refer to symptom list for problems related to Power Folding Mirrors. No → Go To 2 2 Disconnect the Power Folding Mirror Switch connector. All Yes → Replace the Power Folding Mirror Switch. Perform BODY VERIFICATION TEST - VER 1. No → Go To 3 3 Disconnect the Power Folding Mirror Switch connector. All Yes → Repair the Folding Mirror Switch Signal circuit for a short to ground. No → Replace the Body Control Module. Perform BODY VERIFICATION TEST - VER 1. 939 POWER MIRROR |