Symptom: INCOMPLETE POWER OPEN - FULL OPEN SWITCH FAILURE When Monitored and Set Condition: INCOMPLETE POWER OPEN - FULL OPEN SWITCH FAILURE When Monitored: Whenever the power sliding door is operating in the opening direction. Set Condition: The Full Open Switch was detected as closed before 200 hall effect pulses were counted since the start of the open operation. POSSIBLE CAUSES DTC PRESENT STICKING CABLES OR SWITCH FULL OPEN SWITCH SENSE CIRCUIT SHORT TO GROUND FULL OPEN SWITCH TEST ACTION APPLICABILITY 1 With the DRBIII t, record and erase DTC’s. Turn the ignition off, wait 10 seconds, then turn the ignition on. t, read ACTIVE DTCs. Does the DRBIII t display INCOMPLETE POWER OPEN - FULL OPEN SWITCH FAILURE? All Yes → Go To 2 No → Using the wiring diagram/schematic as a guide, inspect the wiring and connectors for an intermittent condition. Operate the 2 Examine the door for proper fit and alignment, foreign material in the lower drive t in Inputs/Outputs, read the FULL OPEN SWITCH state. Manually operate the door handle while monitoring the DRBIII t. Does the switch status change smoothly as the handle is pulled and released? All Yes → Go To 3 No → Refer to Service information for the related symptom(S). Perform BODY VERIFICATION TEST - VER 1. 895 POWER DOORS - SLIDING |