PARAMETER
DESCRIPTION
FAULT CODE
1094
FAULT MESSAGE
Field Shunting Contactor FS21/FS24 Circuit Open.
RESTRICTIONS
Field Shunting Prohibited, Motoring in PARALLEL Prohibited
ALARM BELL
30 seconds
RESET LEVEL
Medium, Manual
After manual reset if the fault still present, the fault will be generated
again.
FAULT
Automatic when master handle is brought to IDLE. Auto fault recovery
RECOVERY
is permitted for 3 times in an hour. There after manual reset is
required.
PROBABLE
1. Defective FS21 or FS24 contactors. (Not picking up).
CAUSES
2. Open circuited FSR21 or FSR24 resistor panels.
3. Disconnected/burnt FSR cables.
FAULT
1. Set the display mode to ‘Manual Test for Outputs’ available under
ISOLATION
Test Mode menu option in the main menu.
2. To test FSR relay operation, enter 24 and press ‘Enter’ key.
3. Press 1 to energise FSR relay. FSR relay energises.
4. FSFB status Green LED 10 on the digital input card 4 MDIP16 in slot
12 should glow. FS contactors also should pick up.
5. Check the status of FS21 and FS24 contactors.
6. If the contactors are not picking up, check the Voltage between
wire 13 at FSR interlock and locomotive 4 wire.
A. If the voltage is zero, check the continuity of 13 wire connected
to FSR interlock.
7. If the voltage is more than 65V, check the voltage between wire
FS1 at the FSR interlock and locomotive 4 wire.
A. If the voltage is zero, the interlock is bad. Replace the FSRrelay.
8. If the voltage is more than 65V, check the voltage between wire
FS1 at FS contactor coil and locomotive 4 wire.
A. If the voltage is zero, the wire FS1 from FSR relay interlock to
FS21 coil is open circuited. Replace the loop.
9. If the voltage is more than 65V, check the voltage across FS21 coil
terminals.
A. If the voltage is zero, the 4 wire connected to FS21 coil is open
circuited. Check the continuity of 4 wire connected to FS
contactor coils.
10. If the voltage is more than 65V, and FS contactor is not picking up,
the FS contactor is defective. Replace the FS contactor.
11. If FS24 alone not picking up,
A. the loop wires of either FS1 or 4 might have open circuited.
Check and replace.
B. The operating coil might be defective. Replace the FS contactor.
12. Check the FSR cables connected between REV and FS contactors for
any open circuit. If any replace the open circuited cables.
13. Check the FSR cables connected between FS contactors and FSR
resistors. Replace any open circuited cables.
14. Check FSR resistors. Replace any open circuited FSRs.
98
15. Check the FSR cables connected between FSR resistors and REV.
Replace any open circuited cables.
Note: This Error message will be generated only if either “Series Field Shunting” or
“Parallel Field Shunting” ENABLED flags are set (√).
99
PARAMETER
DESCRIPTION
FAULT CODE
1095
FAULT MESSAGE
Field Shunting Contactor FS22/FS25 Circuit Open.
RESTRICTIONS
Field Shunting Prohibited, Motoring in PARALLEL Prohibited
ALARM BELL
30 seconds
RESET LEVEL
Medium, Manual
After manual reset if the fault still present, the fault will be generated
again.
FAULT
Automatic when master handle is brought to IDLE. Auto fault recovery
RECOVERY
is permitted for 3 times in an hour. There after manual reset is
required.
PROBABLE
1. Defective FS22 or FS25 contactors. (Not picking up).
CAUSES
2. Open circuited FSR22 or FSR25 resistor panels.
3. Disconnected/burnt FSR cables.
FAULT
1. Set the display mode to ‘Manual Test for Outputs’ available under
ISOLATION
Test Mode menu option in the main menu.
2. To test FSR relay operation, enter 24 and press ‘Enter’ key.
3. Press 1 to energise FSR relay. FSR relay energises.
4. FSFB status Green LED 10 on the digital input card 4 MDIP16 in slot
12 should glow. FS contactors also should pick up.
5. Check the status of FS22 and FS25 contactors.
6. If the contactors are not picking up, check the Voltage between
wire 13 at FSR interlock and locomotive 4 wire.
A. If the voltage is zero, check the continuity of 13 wire connected
to FSR interlock.
7. If the voltage is more than 65V, check the voltage between wire
FS2 at the FSR interlock and locomotive 4 wire.
A. If the voltage is zero, the interlock is bad. Replace the FSRrelay.
8. If the voltage is more than 65V, check the voltage between wire
FS2 at FS contactor coil and locomotive 4 wire.
A. If the voltage is zero, the wire FS2 from FSR relay interlock to
FS22 coil is open circuited. Replace the loop.
9. If the voltage is more than 65V, check the voltage across FS22 coil
terminals.
A. If the voltage is zero, the 4 wire connected to FS22 coil is open
circuited. Check the continuity of 4 wire connected to FS
contactor coils.
10. If the voltage is more than 65V, and FS contactor is not picking up,
the FS contactor is defective. Replace the FS contactor.
11. If FS25 alone not picking up,
A. The loop wires of either FS2 or 4 might have open circuited.
Check and replace.
B. The operating coil might be defective. Replace the FS contactor.
12. Check the FSR cables connected between REV and FS contactors for
any open circuit. If any replace the open circuited cables.
13. Check the FSR cables connected between FS contactors and FSR
resistors. Replace any open circuited cables.
14. Check FSR resistors. Replace any open circuited FSRs.
100
15. Check the FSR cables connected between FSR resistors and REV.
Replace any open circuited cables.
Note: This Error message will be generated only if either “Series Field Shunting” or
“Parallel Field Shunting” ENABLED flags are set (√).
101
PARAMETER
DESCRIPTION
FAULT CODE
1096
FAULT MESSAGE
Field Shunting Contactor FS23/FS26 Circuit Open.
RESTRICTIONS
Field Shunting Prohibited, Motoring in PARALLEL Prohibited
ALARM BELL
30 seconds
RESET LEVEL
Medium, Manual
After manual reset if the fault still present, the fault will be generated
again.
FAULT
Automatic when master handle is brought to IDLE. Auto fault recovery
RECOVERY
is permitted for 3 times in an hour. There after manual reset is
required.
PROBABLE
1. Defective FS21 or FS24 contactors. (Not picking up).
CAUSES
2. Open circuited FSR23 or FSR26 resistor panels.
3. Disconnected/burnt FSR cables.
FAULT
1. Set the display mode to ‘Manual Test for Outputs’ available under
ISOLATION
Test Mode menu option in the main menu.
2. To test FSR relay operation, enter 24 and press ‘Enter’ key.
3. Press 1 to energise FSR relay. FSR relay energises.
4. FSFB status Green LED 10 on the digital input card 4 MDIP16 in slot
12 should glow. FS contactors also should pick up.
5. Check the status of FS23 and FS26 contactors.
6. If the contactors are not picking up, check the Voltage between
wire 13 at FSR interlock and locomotive 4 wire.
A. If the voltage is zero, check the continuity of 13 wire connected
to FSR interlock.
7. If the voltage is more than 65V, check the voltage between wire
FS3 at the FSR interlock and locomotive 4 wire.
A. If the voltage is zero, the interlock is bad. Replace the FSRrelay.
8. If the voltage is more than 65V, check the voltage between wire
FS3 at FS contactor coil and locomotive 4 wire.
A. If the voltage is zero, the wire FS3 from FSR relay interlock to
FS23 coil is open circuited. Replace the loop.
9. If the voltage is more than 65V, check the voltage across FS23 coil
terminals.
A. If the voltage is zero, the 4 wire connected to FS23 coil is open
circuited. Check the continuity of 4 wire connected to FS
contactor coils.
10. If the voltage is more than 65V, and FS contactor is not picking up,
the FS contactor is defective. Replace the FS contactor.
11. If FS26 alone not picking up,
A. the loop wires of either FS1 or 4 might have open circuited.
Check and replace.
B. The operating coil might be defective. Replace the FS contactor.
12. Check the FSR cables connected between REV and FS contactors for
any open circuit. If any replace the open circuited cables.
13. Check the FSR cables connected between FS contactors and FSR
resistors. Replace any open circuited cables.
14. Check FSR resistors. Replace any open circuited FSRs.
102
Check the FSR cables connected between FSR resistors and REV.
Replace any open circuited cables.
Note: This Error message will be generated only if either “Series Field Shunting” or
“Parallel Field Shunting” ENABLED flags are set (√).
103
PARAMETER
DESCRIPTION
FAULT CODE
1097
FAULT MESSAGE
Traction Alternator out put short ckt. fault
RESTRICTIONS
Motoring and dynamic brake prohibited
ALARM BELL
30 seconds
RESET LEVEL
Medium, Manual
After manual reset if the fault still present, the fault will be generated
again.
FAULT
Automatic when master handle is brought to IDLE. Auto fault recovery
RECOVERY
is permitted for 2 times in an hour. There after manual reset is
required.
PROBABLE
The message is logged whenever a short circuit is exhibited across
CAUSES
GA11 and GA2 terminals. The short circuit might be a momentary or a
permanent cause.
1. Fluttering of power contactor due to improper air supply and
causing momentary short circuit across GA11 & GA2.
1.
Power contactor stuck in mid position momentary / permanent.
2.
Defective wiring in the power circuit.
3.
Momentary short across GA11 and GA2 cables due to any foreign
body in BKT/REV contactors.
4.
Burnt / short circuited diodes in power rectifier.
FAULT
1.
Check for any welded power contactors. If any power contactors
ISOLATION
are welded, check for the falowing defects.
A. Control air pressure is less. If so adjust to 5 Kgs./Sq.cm.
B. Check for air leakages in the pneumatic pipeline connected
to power contactor. If necessary replace the pneumatic pipe.
C. Replace the power contactor and ensure proper operation of
the power contactors.
2.
If power contactors are not in welded condition, check for any
welded symptoms of PC welding on the tips. If welding symptoms
are found, replace the power contactor.
3.
Run Auto / manual test for digital outputs and ensure that there are
no faults recorded on power contactors during self-test.
4.
If any faults are logged, adjust the auxiliary contacts as per the
maintanance instructions on PC aux. Interlocks Docment No. IM-57
5.
If Power contactor are in healthy condition, check for burnt / over
heated / flashed contacts on BKT / REV.
(Any metallic foreign
materials fallen on BKT can cause momentary short circuit).
6.
If any burnt / over heated / flashed contacts in BKT / REV clean the
contacts and ensure proper operation of BKT / REV.
7.
Reset the fault and set the loco to Motoring position and open the
1st Notch, if TAAI is equals to sum of all TM currents it indicates the
faulty momentary and it is cleared.
8.
If no TM currents are sensed check for any short circuit between
GA11 and GA2. Identify the short circuit and rectify.
104
PARAMETER
DESCRIPTION
FAULT CODE
1102
FAULT MESSAGE
P2 Stuck Closed without Aux Contact ON. Check if Contact welded.
RESTRICTIONS
Series Motoring &
Dynamic Braking.
ALARM BELL
30 seconds
RESET LEVEL
Medium, Manual
After manual reset if the fault still present, the fault will be generated
again.
FAULT
--
RECOVERY
PROBABLE
1. Defective P2 contactor.
CAUSES
2. Defective aux. interlock of P2 contactor.
3. Defective wiring.
4. Defective TM1AI current sensor.
5. Defective MDIP16 card in slot no: 10.
FAULT
This message will log whenever Traction Motor 1 current is sensed
ISOLATION
through TM1AI but P2 contactor aux. interlock feed back is not sensed.
Due to delayed operation of contactor or contactor stuck in mid
position can cause the above fault.
1.
Check the status of the P2 power contactor. If the contactor is
stuck in mid position replace the contactor.
2.
If the contactor is normal,
A. Check the operation of the power contactor by manually
operating the magnetvalve. Ensue that the contactor is
operating freely with out any delay. If the contactor is sluggish
in operation replace the contactor.
B. Run manual test for the power contactor and ensure the
feedback is detected correctly by the system.
3.
If the Feed back is not detected by the system in the manual test,
A. Check the status of green LED 6 on digital input card MDIP16 in
slot No.10. If the LED glows while the contactor is ON:
a. Then the MDIP16 card is defective. Replace the card.
B. If the green LED is not glowing while the contactor pick up,
check the volage between wires P2 FB and 4 wire.
C. If Voltage is mre than 65V, then the connector of cable ID: AU
is slack or the wire P2FB is open circuited. Identify and rectify.
If necessary replace the cable.
D. If voltage is zero, check the voltage between 51 and 4 at the
auxiliary contact of P2. If voltage is more than 65V, the Aux.
Cntact is bad. Replace the aux. Contacts of power contactor.
E. If the voltage is zero, wire loop of 51 wire is defective. Identify
and replace.
4.
If every thing is normal, check the current of TM No.1 while
opening the first notch and set the display to wheel slip mode.
A. If the TM1 current is showing abnormally high as compared to
4th TM current, check the currents in parallel operation.
B. Compare the TM1 current with all other TM currents.
C. If the TM1 current is abnormally high, replace the current
sensor of TM1.
Note: This fault can be sometimes transient. If no trouble is found,
105
check for any welding symptoms of power contactor tips. Clean the tips
and ensure the control air pressure is set to 5 Kgs./cm. Sq.
106
PARAMETER
DESCRIPTION
FAULT CODE
1103
FAULT MESSAGE
P32 Stuck Closed without Aux Contact ON. Check if Contact welded.
RESTRICTIONS
Series Motoring &
Dynamic Braking.
ALARM BELL
30 seconds
RESET LEVEL
Medium, Manual
After manual reset if the fault still present, the fault will be generated
again.
FAULT
--
RECOVERY
PROBABLE
1. Defective P32 contactor.
CAUSES
2. Defective aux. interlock of P32 contactor.
3. Defective wiring.
4. Defective TM2AI current sensor.
5. Defective MDIP16 card in slot no: 10.
FAULT
This message will log whenever Traction Motor 2 current is sensed
ISOLATION
through TM2AI but P32 contactor aux. interlock feed back is not
sensed. Due to delayed operation of contactor or contactor stuck in
mid position can cause the above fault.
1.
Check the status of the P32 power contactor. If the contactor is
stuck in mid position replace the contactor.
2.
If the contactor is normal,
A. Check the operation of the power contactor by manually
operating the magnetvalve. Ensue that the contactor is
operating freely with out any delay. If the contactor is sluggish
in operation replace the contactor.
B. Run manual test for the power contactor and ensure the
feedback is detected correctly by the system.
3.
If the Feed back is not detected by the system in the manual test,
A. Check the status of green LED 8 on digital input card MDIP16 in
slot No.10. If the LED glows while the contactor is ON:
a. Then the MDIP16 card is defective. Replace the card.
B. If the green LED is not glowing while the contactor pick up,
check the volage between wires P32 FB and 4 wire.
C. If Voltage is mre than 65V, then the connector of cable ID: AU
is slack or the wire P32FB is open circuited. Identify and rectify.
If necessary replace the cable.
D. If voltage is zero, check the voltage between 51 and 4 at the
auxiliary contact of P32. If voltage is more than 65V, the Aux.
Cntact is bad. Replace the aux. Contacts of power contactor.
E. If the voltage is zero, wire loop of 51 wire is defective. Identify
and replace.
4.
If every thing is normal, check the current of TM No.2 while
opening the first notch and set the display to wheel slip mode.
A. If the TM2 current is showing abnormally high as compared to
5th TM current, check the currents in parallel operation.
B. Compare the TM2 current with all other TM currents.
C. If the TM2 current is abnormally high, replace the current
sensor of TM2.
107
Note: This fault can be sometimes transient. If no trouble is found,
check for any welding symptoms of power contactor tips. Clean the tips
and ensure the control air pressure is set to 5 Kgs./cm. Sq.
108
PARAMETER
DESCRIPTION
FAULT CODE
1104
FAULT MESSAGE
P22 Stuck Closed without Aux Contact ON. Check if Contact welded.
RESTRICTIONS
Series Motoring &
Dynamic Braking.
ALARM BELL
30 seconds
RESET LEVEL
Medium, Manual
After manual reset if the fault still present, the fault will be generated
again.
FAULT
--
RECOVERY
PROBABLE
1. Defective P22 contactor.
CAUSES
2. Defective aux. interlock of P22 contactor.
3. Defective wiring.
4. Defective TM3AI current sensor.
5. Defective MDIP16 card in slot no: 10.
FAULT
This message will log whenever Traction Motor 3 current is sensed
ISOLATION
through TM3AI but P22 contactor aux. interlock feed back is not
sensed. Due to delayed operation of contactor or contactor stuck in
mid position can cause the above fault.
1.
Check the status of the P22 power contactor. If the contactor is
stuck in mid position replace the contactor.
2.
If the contactor is normal,
A. Check the operation of the power contactor by manually
operating the magnetvalve. Ensue that the contactor is
operating freely with out any delay. If the contactor is sluggish
in operation replace the contactor.
B. Run manual test for the power contactor and ensure the
feedback is detected correctly by the system.
3.
If the Feed back is not detected by the system in the manual test,
A. Check the status of green LED 7 on digital input card MDIP16 in
slot No.10. If the LED glows while the contactor is ON:
a. Then the MDIP16 card is defective. Replace the card.
B. If the green LED is not glowing while the contactor pick up,
check the volage between wires P22 FB and 4 wire.
C. If Voltage is mre than 65V, then the connector of cable ID: AU
is slack or the wire P22FB is open circuited. Identify and rectify.
If necessary replace the cable.
D. If voltage is zero, check the voltage between 51 and 4 at the
auxiliary contact of P22. If voltage is more than 65V, the Aux.
Cntact is bad. Replace the aux. Contacts of power contactor.
E. If the voltage is zero, wire loop of 51 wire is defective. Identify
and replace.
4.
If every thing is normal, check the current of TM No.3 while
opening the first notch and set the display to wheel slip mode.
A. If the TM1 current is showing abnormally high as compared to
6th TM current, check the currents in parallel operation.
B. Compare the TM3 current with all other TM currents.
C. If the TM3 current is abnormally high, replace the current
sensor of TM3.
109
Note: This fault can be sometimes transient. If no trouble is found,
check for any welding symptoms of power contactor tips. Clean the tips
and ensure the control air pressure is set to 5 Kgs./cm. Sq.
110
PARAMETER
DESCRIPTION
FAULT CODE
1105
FAULT MESSAGE
P1 Stuck Closed without Aux Contact ON. Check if Contact welded.
RESTRICTIONS
Series Motoring &
Dynamic Braking.
ALARM BELL
30 seconds
RESET LEVEL
Medium, Manual
After manual reset if the fault still present, the fault will be generated
again.
FAULT
--
RECOVERY
PROBABLE
1. Defective P1 contactor.
CAUSES
2. Defective aux. interlock of P1 contactor.
3. Defective wiring.
4. Defective TM4AI current sensor.
5. Defective MDIP16 card in slot no: 10.
FAULT
This message will log whenever Traction Motor 4 current is sensed
ISOLATION
through TM4AI but P1 contactor aux. interlock feed back is not sensed.
Due to delayed operation of contactor or contactor stuck in mid
position can cause the above fault.
1.
Check the status of the P1 power contactor. If the contactor is
stuck in mid position replace the contactor.
2.
If the contactor is normal,
A. Check the operation of the power contactor by manually
operating the magnetvalve. Ensue that the contactor is
operating freely with out any delay. If the contactor is sluggish
in operation replace the contactor.
B. Run manual test for the power contactor and ensure the
feedback is detected correctly by the system.
3.
If the Feed back is not detected by the system in the manual test,
A. Check the status of green LED 3 on digital input card MDIP16 in
slot No.10. If the LED glows while the contactor is ON:
a. Then the MDIP16 card is defective. Replace the card.
B. If the green LED is not glowing while the contactor pick up,
check the volage between wires P1 FB and 4 wire.
C. If Voltage is mre than 65V, then the connector of cable ID: AU
is slack or the wire P1FB is open circuited. Identify and rectify.
If necessary replace the cable.
D. If voltage is zero, check the voltage between 51 and 4 at the
auxiliary contact of P1. If voltage is more than 65V, the Aux.
Cntact is bad. Replace the aux. Contacts of power contactor.
E. If the voltage is zero, wire loop of 51 wire is defective. Identify
and replace.
4.
If every thing is normal, check the current of TM No.4 while
opening the first notch and set the display to wheel slip mode.
A. If the TM4 current is showing abnormally high as compared to
1st TM current, check the currents in parallel operation.
B. Compare the TM4 current with all other TM currents.
C. If the TM4 current is abnormally high, replace the current
sensor of TM4.
111
Note: This fault can be sometimes transient. If no trouble is found,
check for any welding symptoms of power contactor tips. Clean the tips
and ensure the control air pressure is set to 5 Kgs./cm. Sq.
112
PARAMETER
DESCRIPTION
FAULT CODE
1106
FAULT MESSAGE
P31 Stuck Closed without Aux Contact ON. Check if Contact welded.
RESTRICTIONS
Series Motoring &
Dynamic Braking.
ALARM BELL
30 seconds
RESET LEVEL
Medium, Manual
After manual reset if the fault still present, the fault will be generated
again.
FAULT
--
RECOVERY
PROBABLE
1. Defective P31 contactor.
CAUSES
2. Defective aux. interlock of P31 contactor.
3. Defective wiring.
4. Defective TM5AI current sensor.
5. Defective MDIP16 card in slot no: 10.
FAULT
This message will log whenever Traction Motor 5 current is sensed
ISOLATION
through TM5AI but P31 contactor aux. interlock feed back is not
sensed. Due to delayed operation of contactor or contactor stuck in
mid position can cause the above fault.
1.
Check the status of the P31 power contactor. If the contactor is
stuck in mid position replace the contactor.
2.
If the contactor is normal,
A. Check the operation of the power contactor by manually
operating the magnetvalve. Ensue that the contactor is
operating freely with out any delay. If the contactor is sluggish
in operation replace the contactor.
B. Run manual test for the power contactor and ensure the
feedback is detected correctly by the system.
3.
If the Feed back is not detected by the system in the manual test,
A. Check the status of green LED 4 on digital input card MDIP16 in
slot No.10. If the LED glows while the contactor is ON:
a. Then the MDIP16 card is defective. Replace the card.
B. If the green LED is not glowing while the contactor pick up,
check the volage between wires P31 FB and 4 wire.
C. If Voltage is mre than 65V, then the connector of cable ID: AU
is slack or the wire P31FB is open circuited. Identify and rectify.
If necessary replace the cable.
D. If voltage is zero, check the voltage between 51 and 4 at the
auxiliary contact of P31. If voltage is more than 65V, the Aux.
Cntact is bad. Replace the aux. Contacts of power contactor.
E. If the voltage is zero, wire loop of 51 wire is defective. Identify
and replace.
4.
If every thing is normal, check the current of TM No.5 while
opening the first notch and set the display to wheel slip mode.
A. If the TM5 current is showing abnormally high as compared to
2rd TM current, check the currents in parallel operation.
B. Compare the TM5 current with all other TM currents.
C. If the TM5 current is abnormally high, replace the current
sensor of TM5.
113
Note: This fault can be sometimes transient. If no trouble is found,
check for any welding symptoms of power contactor tips. Clean the tips
and ensure the control air pressure is set to 5 Kgs./cm. Sq.
114
PARAMETER
DESCRIPTION
FAULT CODE
1107
FAULT MESSAGE
P21 Stuck Closed without Aux Contact ON. Check if Contact welded.
RESTRICTIONS
Series Motoring &
Dynamic Braking.
ALARM BELL
30 seconds
RESET LEVEL
Medium, Manual
After manual reset if the fault still present, the fault will be generated
again.
FAULT
--
RECOVERY
PROBABLE
1. Defective P21 contactor.
CAUSES
2. Defective aux. interlock of P21 contactor.
3. Defective wiring.
4. Defective TM6AI current sensor.
5. Defective MDIP16 card in slot no: 10.
FAULT
This message will log whenever Traction Motor 6 current is sensed
ISOLATION
through TM6AI but P21 contactor aux. interlock feed back is not
sensed. Due to delayed operation of contactor or contactor stuck in
mid position can cause the above fault.
1.
Check the status of the P21 power contactor. If the contactor is
stuck in mid position replace the contactor.
2.
If the contactor is normal,
A. Check the operation of the power contactor by manually
operating the magnetvalve. Ensue that the contactor is
operating freely with out any delay. If the contactor is sluggish
in operation replace the contactor.
B. Run manual test for the power contactor and ensure the
feedback is detected correctly by the system.
3.
If the Feed back is not detected by the system in the manual test,
A. Check the status of green LED 5 on digital input card MDIP16 in
slot No.10. If the LED glows while the contactor is ON:
a. Then the MDIP16 card is defective. Replace the card.
B. If the green LED is not glowing while the contactor pick up,
check the volage between wires P21 FB and 4 wire.
C. If Voltage is mre than 65V, then the connector of cable ID: AU
is slack or the wire P21FB is open circuited. Identify and rectify.
If necessary replace the cable.
D. If voltage is zero, check the voltage between 51 and 4 at the
auxiliary contact of P21. If voltage is more than 65V, the Aux.
Cntact is bad. Replace the aux. Contacts of power contactor.
E. If the voltage is zero, wire loop of 51 wire is defective. Identify
and replace.
4.
If every thing is normal, check the current of TM No.6 while
opening the first notch and set the display to wheel slip mode.
A. If the TM6 current is showing abnormally high as compared to
3rd TM current, check the currents in parallel operation.
B. Compare the TM6 current with all other TM currents.
C. If the TM6 current is abnormally high, replace the current
sensor of TM6.
115
Note: This fault can be sometimes transient. If no trouble is found,
check for any welding symptoms of power contactor tips. Clean the tips
and ensure the control air pressure is set to 5 Kgs./cm. Sq.
116
3.0. MEDIUM PRIORITY FAULTS
PARAMETER
DESCRIPTION
FAULT CODE
1118
FAULT MESSAGE
Excess Traction Motor 1 Current. Maximum TM current limited.
RESTRICTIONS
Maximum TM Current LIMITED.
ALARM BELL
5 seconds
RESET LEVEL
Low, Manual
After manual reset if the fault still present, the fault will be generated
again.
FAULT
Automatic when traction motors get cooled.
RECOVERY
PROBABLE
1. Driver might have worked more time than the stipulated time in the
CAUSES
restricted zone of the load meter.
FAULT
1. The fault will get reset automatically.
ISOLATION
PARAMETER
DESCRIPTION
FAULT CODE
1119
FAULT MESSAGE
Excess Traction Motor 2 Current. Maximum TM current limited.
RESTRICTIONS
Maximum TM Current LIMITED.
ALARM BELL
5 seconds
RESET LEVEL
Low, Manual
After manual reset if the fault still present, the fault will be generated
again.
FAULT
Automatic when traction motors get cooled.
RECOVERY
PROBABLE
1. Driver might have worked more time than the stipulated time in the
CAUSES
restricted zone of the load meter.
FAULT
1. The fault will get reset automatically.
ISOLATION
117
PARAMETER
DESCRIPTION
FAULT CODE
1120
FAULT MESSAGE
Excess Traction Motor 3 Current. Maximum TM current limited.
RESTRICTIONS
Maximum TM Current LIMITED.
ALARM BELL
5 seconds
RESET LEVEL
Low, Manual
After manual reset if the fault still present, the fault will be generated
again.
FAULT
Automatic when traction motors get cooled.
RECOVERY
PROBABLE
1. Driver might have worked more time than the stipulated time in the
CAUSES
restricted zone of the load meter.
FAULT
1. The fault will get reset automatically.
ISOLATION
PARAMETER
DESCRIPTION
FAULT CODE
1121
FAULT MESSAGE
Excess Traction Motor 4 Current. Maximum TM current limited.
RESTRICTIONS
Maximum TM Current LIMITED.
ALARM BELL
5 seconds
RESET LEVEL
Low, Manual
After manual reset if the fault still present, the fault will be generated
again.
FAULT
Automatic when traction motors get cooled.
RECOVERY
PROBABLE
1. Driver might have worked more time than the stipulated time in the
CAUSES
restricted zone of the load meter.
FAULT
1. The fault will get reset automatically.
ISOLATION
118
PARAMETER
DESCRIPTION
FAULT CODE
1122
FAULT MESSAGE
Excess Traction Motor 5 Current. Maximum TM current limited.
RESTRICTIONS
Maximum TM Current LIMITED.
ALARM BELL
5 seconds
RESET LEVEL
Low, Manual
After manual reset if the fault still present, the fault will be generated
again.
FAULT
Automatic when traction motors get cooled.
RECOVERY
PROBABLE
1. Driver might have worked more time than the stipulated time in the
CAUSES
restricted zone of the load meter.
FAULT
1. The fault will get reset automatically.
ISOLATION
PARAMETER
DESCRIPTION
FAULT CODE
1123
FAULT MESSAGE
Excess Traction Motor 6 Current. Maximum TM current limited.
RESTRICTIONS
Maximum TM Current LIMITED.
ALARM BELL
5 seconds
RESET LEVEL
Low, Manual
After manual reset if the fault still present, the fault will be generated
again.
FAULT
Automatic when traction motors get cooled.
RECOVERY
PROBABLE
1. Driver might have worked more time than the stipulated time in the
CAUSES
restricted zone of the load meter.
FAULT
1. The fault will get reset automatically.
ISOLATION
119
PARAMETER
DESCRIPTION
FAULT CODE
1124
FAULT MESSAGE
S1 stuck open. Run Auto/manual test.
Power Limited. Power circuit problem
RESTRICTIONS
Reference power is reduced by 1/3 times of such faults while motoring
in 2S-3P mode.
Dynamic brake prohibited.
ALARM BELL
5 seconds
RESET LEVEL
Low, Manual
After manual reset if the fault still present, the fault will be generated
again.
FAULT
Automatic when S1 power contactor closes.
RECOVERY
PROBABLE
1. Defective power contactor.
CAUSES
2. Bad wiring.
3. Slackness in connector of cable ID: AY at MEP-660.
4. Defective digital output card MLSD 16 in slot 14.
5. Slackness in connector of cable ID: AU at MEP-660
6. Defective digital input card MDIP 16 in slot 10.
FAULT
This fault will be logged due to delayed / sluggish operation of power
ISOLATION
contactors. The fault may not exist while troubleshooting. In such case
check and ensure that the power contactor is operating freely and the
auxiliary contact is having sufficient over travel and pressure.
1.
Check and ensure control air pressure is 5Kg./Sq.Cm. If control air
pressure is less/excess adjust to 5Kg./Sq./Cm.
2.
Operate the power contactor manually by pressing armature plate
of the magnet valve.
3.
If the power contactor is not operating:
A. Defective pneumatic pipeline. Check and replace the pipeline.
B. Defective magnet valve. Check and replace.
C. Defective power contactor. Check and replace.
4.
If the power contactor is operating, set up the display to ‘Manual
Test for Outputs’ under ‘Test Mode’ menu option.
5.
Enter 6 and press ‘Enter’ key to test S1 power contactor operation.
6.
Press 1 to energise the S1 contactor.
7.
If S1 is not picking up, check voltage at the power contactor
magnet valve terminals.
A. If the voltage is more than 65V, magnet valve coil is defective.
Replace the magnet valve.
8.
If the voltage is zero, check voltage at coil terminal (wire 13) with
respect to locomotive 4 wire.
A. If the voltage is zero, check the continuity of 13-wire loop
coming to magnet valve coil. Check and replace open circuited
wire/wrong connection.
9.
If the voltage is more than 60 V, Check the supply voltage between
loco wire 50 and magnet valve coil terminal S1CL.
A. If voltage is zero, there is no continuity of wire S1CL from MEP-
660 to magnet valve.
a) Check slackness of connector of (Cable ID: AY) at MEP-660. If
slack tighten the connector.
b) Check the continuity of S1CL wire from MEP-660 to magnet
120
valve coil terminal (Cable ID: AY, Pin-G). If necessary replace
the cable.
c) If the continuity is good and there is no slackness in
connector, then the digital output card MLSD 16 in slot No. 14
is defective. Replace the card.
10. If S1 is picking up, check the status of Green LED 9 on the digital
input card 2 in slot 10.
11. If the Green LED 9 is not glowing check Voltage at auxiliary contact
(wire No. 51) with respect to locomotive 4 wire.
A. If voltage is zero, check the continuity of 51-wire loop coming to
S1 power contactor auxiliary contact.
12. If voltage is more than 65V, then check voltage at auxiliary contact
(wire no. S1FB) with respect to locomotive 4 wire.
A. If voltage is zero, the auxiliary contact is bad. Replace the
auxiliary contacts.
13. If voltage is more than 60 V,
A. Check the slackness of connector of cable ID: AU at MEP-660. If
slack tighten and check the LED status.
B. Check the continuity of Wire S1FB from S1 power contactor to
MEP-660. (Cable ID: AU, Pin-K). If necessary replace the cable.
14. If the Green LED 9 is glowing:
A. Check the status of corresponding Yellow LED on the same card.
B. If the yellow LED is not glowing, then the digital input card MDIP
16 in slot No. 10 is defective. Replace the card and check.
15. If Both Green and Yellow LEDs 9 are glowing on the digital input
card MDIP 16 in slot 10, the feed back status should be displayed
ON. Toggle the S1 contactor operation two to three times and
ensure the feedback signal is changing accordingly.
121
PARAMETER
DESCRIPTION
FAULT CODE
1125
FAULT MESSAGE
S21 stuck open. Run Auto/manual test.
Power Limited. Power circuit problem
RESTRICTIONS
Reference power is reduced by 1/3 times of such faults while motoring
in 2S-3P mode.
ALARM BELL
5 seconds
RESET LEVEL
Low, Manual
After manual reset if the fault still present, the fault will be generated
again.
FAULT
Automatic when S21 power contactor closes.
RECOVERY
PROBABLE
1. Defective power contactor.
CAUSES
2. Bad wiring.
3. Slackness in connector of cable ID: AY at MEP-660.
4. Defective digital output card MLSD 16 in slot 14.
5. Slackness in connector of cable ID: AU at MEP-660
6. Defective digital input card MDIP 16 in slot 10.
FAULT
This fault will be logged due to delayed / sluggish operation of power
ISOLATION
contactors. The fault may not exist while troubleshooting. In such case
check and ensure that the power contactor is operating freely and the
auxiliary contact is having sufficient over travel and pressure.
1.
Check and ensure control air pressure is 5Kg./Sq.Cm. If control air
pressure is less/excess adjust to 5Kg./Sq./Cm.
2.
Operate the power contactor manually by pressing armature plate
of the magnet valve.
3.
If the power contactor is not operating:
A. Defective pneumatic pipeline. Check and replace the pipeline.
B. Defective magnet valve. Check and replace.
C. Defective power contactor. Check and replace.
4.
If the power contactor is operating, set up the display to ‘Manual
Test for Outputs’ under ‘Test Mode’ menu option.
5.
Enter 7 and press ‘Enter’ key to test S21 power contactor
operation.
6.
Press 1 to energise the S21 contactor.
7.
If S21 is not picking up, check voltage at the power contactor
magnet valve terminals.
A. If the voltage is more than 65V, magnet valve coil is defective.
Replace the magnet valve.
8.
If the voltage is zero, check voltage at coil terminal (wire 13) with
respect to locomotive 4-wire.
A. If the voltage is zero, check the continuity of 13-wire loop
coming to magnet valve coil. Check and replace open circuited
wire/wrong connection.
9.
If the voltage is more than 65 V, Check the supply voltage between
loco wire 50 and magnet valve coil terminal S21CL.
A. If voltage is zero, there is no continuity of wire S21CL from
MEP-660 to magnet valve.
a) Check slackness of connector of (Cable ID: AY) at MEP-660. If
slack tighten the connector.
b) Check the continuity of S21CL wire from MEP-660 to magnet
122
valve coil terminal (Cable ID: AY, Pin-H). If necessary replace
the cable.
c) If the continuity is good and there is no slackness in
connector, then the digital output card MLSD 16 in slot No. 14
is defective. Replace the card.
10. If S21 is picking up, check the status of Green LED 10 on the digital
input card 2 in slot 10.
11. If the Green LED 10 is not glowing, check supply Voltage at
auxiliary contact (wire No. 51) with respect to locomotive 4 wire.
A. If voltage is zero, check the continuity of 51-wire loop coming to
S21 power contactor auxiliary contact.
12. If voltage is more than 65V, then check voltage at auxiliary contact
(wire no. S21FB) with respect to locomotive 4 wire.
A. If voltage is zero, the auxiliary contact is bad. Replace the
auxiliary contacts.
13. If voltage is more than 60 V,
A. Check the slackness of connector of cable ID: AU at MEP-660. If
slack tighten and check the LED status.
B. Check the continuity of Wire S21FB from S21 power contactor to
MEP-660. (Cable ID: AU, Pin-L). If necessary replace the cable.
14. If the Green LED 10 is glowing:
A. Check the status of corresponding Yellow LED on the same card.
B. If the yellow LED is not glowing, then the digital input card MDIP
16 in slot No. 10 is defective. Replace the card and check.
15. If Both Green and Yellow LEDs 10 are glowing on the digital input
card MDIP 16 in slot 10, the feed back status should be displayed
ON. Toggle the S21 contactor operation two to three times and
ensure the feedback signal is changing accordingly.
123
PARAMETER
DESCRIPTION
FAULT CODE
1126
FAULT MESSAGE
S31 stuck open. Run Auto/manual test.
Power Limited. Power circuit problem
RESTRICTIONS
Reference power is reduced by 1/3 times of such faults while motoring
in 2S-3P mode.
ALARM BELL
5 seconds
RESET LEVEL
Low, Manual
After manual reset if the fault still present, the fault will be generated
again.
FAULT
Automatic when S31 power contactor closes.
RECOVERY
PROBABLE
1. Defective power contactor.
CAUSES
2. Bad wiring.
3. Slackness in connector of cable ID: AY at MEP-660.
4. Defective digital output card MLSD 16 in slot 14.
5. Slackness in connector of cable ID: AU at MEP-660
6. Defective digital input card MDIP 16 in slot 10.
FAULT
This fault will be logged due to delayed / sluggish operation of power
ISOLATION
contactors. The fault may not exist while troubleshooting. In such case
check and ensure that the power contactor is operating freely and the
auxiliary contact is having sufficient over travel and pressure.
1.
Check and ensure control air pressure is 5Kg./Sq.Cm. If control air
pressure is less/excess adjust to 5Kg./Sq./Cm.
2.
Operate the power contactor manually by pressing armature plate
of the magnet valve.
3.
If the power contctor is not operating:
A. Defective pneumatic pipeline. Check and replace the pipeline.
B. Defective magnet valve. Check and replace.
C. Defective power contactor. Check and replace.
4.
If the power contactor is operating, set up the display to ‘Manual
Test for Outputs’ under ‘Test Mode’ menu option.
5.
Enter 8 and press ‘Enter’ key to test S31 power contactor
operation.
6.
Press 1 to energise the S31 contactor.
7.
If S31 is not picking up, check voltage at the power contactor
magnet valve terminals.
A. If the voltage is more than 65V, magnet valve coil is defective.
Replace the magnet valve.
8.
If the voltage is zero, check voltage at coil terminal (wire 13) with
respect to locomotive 4-wire.
A. If the voltage is zero, check the continuity of 13-wire loop
coming to magnet valve coil. Check and replace open circuited
wire/wrong connection.
9.
If the voltage is more than 60 V, Check the supply voltage between
loco wire 50 and magnet valve coil terminal S31CL.
A. If voltage is zero, there is no continuity of wire S31CL from
MEP-660 to magnet valve.
a) Check slackness of connector of (Cable ID: AY) at MEP-660. If
slack tighten the connector.
b) Check the continuity of S31CL wire from MEP-660 to magnet
124
valve coil terminal (Cable ID: AY, Pin-K). If necessary replace
the cable.
c) If the continuity is good and there is no slackness in
connector, then the digital output card MLSD 16 in slot No. 14
is defective. Replace the card.
10. If S31 is picking up, check the status of Green LED 11 on the digital
input card 2 in slot 10.
11. If the Green LED 11 is not glowing, check supplies Voltage at
auxiliary contact (wire No. 51) with respect to locomotive 4 wire.
A. If voltage is zero, check the continuity of 51-wire loop coming to
S31 power contactor auxiliary contact.
12. If voltage is more than 65V, then check voltage at auxiliary contact
(wire no. S31FB) with respect to locomotive 4 wire.
A. If voltage is zero, the auxiliary contact is bad. Replace the
auxiliary contacts.
13. If voltage is more than 60 V,
A. Check the slackness of connector of cable ID: AU at MEP-660. If
slack tighten and check the LED status.
B. Check the continuity of Wire S31FB from S31 power contactor to
MEP-660. (Cable ID: AU, Pin-M). If necessary replace the cable.
14. If the Green LED 11 is glowing:
A. Check the status of corresponding Yellow LED on the same card.
B. If the yellow LED is not glowing, then the digital input card MDIP
16 in slot No. 10 is defective. Replace the card and check.
15. If Both Green and Yellow LEDs 11 are glowing on the digital input
card MDIP 16 in slot 10, the feed back status should be displayed
ON. Toggle the S31 contactor operation two to three times and
ensure the feedback signal is changing accordingly.
125
PARAMETER
DESCRIPTION
FAULT CODE
1127
FAULT MESSAGE
P1 stuck open. Run Auto/manual test.
Power Limited. Power circuit problem
RESTRICTIONS
Reference power is reduced by 1/6 times of such faults while motoring
in 6P mode.
Dynamic brake prohibited.
ALARM BELL
5 seconds
RESET LEVEL
Low, Manual
After manual reset if the fault still present, the fault will be generated
again.
FAULT
Automatic when P1 power contactor closes.
RECOVERY
PROBABLE
1. Defective power contactor.
CAUSES
2. Bad wiring.
3. Slackness in connector of cable ID: AY at MEP-660.
4. Defective digital output card MLSD 16 in slot 14.
5. Slackness in connector of cable ID: AU at MEP-660
6. Defective digital input card MDIP 16 in slot 10.
FAULT
This fault will be logged due to delayed / sluggish operation of power
ISOLATION
contactors. The fault may not exist while troubleshooting. In such case
check and ensure that the power contactor is operating freely and the
auxiliary contact is having sufficient over travel and pressure.
1. Check and ensure control air pressure is 5Kg./Sq.Cm. If control air
pressure is less/excess adjust to 5Kg./Sq./Cm.
2. Operate the power contactor manually by pressing armature plate
of the magnet valve.
3. If the power contactor is not operating:
A. Defective pneumatic pipeline. Check and replace the pipeline.
B. Defective magnet valve. Check and replace.
C. Defective power contactor. Check and replace.
4. If the power contactor is operating, set up the display to ‘Manual
Test for Outputs’ under ‘Test Mode’ menu option.
5. Enter 0 and press ‘Enter’ key to test P1 power contactor operation.
6. Press 1 to energise the P1 contactor.
7. If P1 is not picking up, check voltage at the power contactor
magnet valve terminals.
8. If the voltage is more than 65V, magnet valve coil is defective.
Replace the magnet valve.
A. If the voltage is zero, check voltage at coil terminal (wire 13)
with respect to locomotive 4-wire.
9. If the voltage is zero, check the continuity of 13-wire loop coming
to magnet valve coil. Check and replace open circuited wire/wrong
connection.
A. If the voltage is more than 60 V, Check the supply voltage
between loco wire 50 and magnet valve coil terminal P1CL.
10. If voltage is zero, there is no continuity of wire P1CL from MEP-660
to magnet valve.
A. Check slackness of connector of (Cable ID: AY) at MEP-660. If
slack tighten the connector.
B. Check the continuity of P1CL wire from MEP-660 to magnet
126
valve coil terminal (Cable ID: AY, Pin-A). If necessary replace
the cable.
C. If the continuity is good and there is no slackness in connector,
then the digital output card MLSD 16 in slot No. 14 is defective.
Replace the card.
11. If P1 is picking up, check the status of Green LED 3 on the digital
input card 2 in slot 10.
12. If the Green LED 3 is not glowing, check supply Voltage at auxiliary
contact (wire No. 51) with respect to locomotive 4 wire.
A. If voltage is zero, check the continuity of 51-wire loop coming to
P1 power contactor auxiliary contact.
13. If voltage is more than 65V, then check voltage at auxiliary contact
(wire no. P1FB) with respect to locomotive 4 wire.
A. If voltage is zero, the auxiliary contact is bad. Replace the
auxiliary contacts.
14. If voltage is more than 60 V,
A. Check the slackness of connector of cable ID: AU at MEP-660. If
slack tighten and check the LED status.
B. Check the continuity of Wire P1FB from P1 power contactor to
MEP-660. (Cable ID: AU, Pin-D). If necessary replace the cable.
15. If the Green LED 3 is glowing:
A. Check the status of corresponding Yellow LED on the same card.
B. If the yellow LED is not glowing, then the digital input card MDIP
16 in slot No. 10 is defective. Replace the card and check.
16. If Both Green and Yellow LEDs 3 are glowing on the digital input
card MDIP 16 in slot 10, the feed back status should be displayed
ON. Toggle the P1 contactor operation two to three times and
ensure the feedback signal is changing accordingly.
127
PARAMETER
DESCRIPTION
FAULT CODE
1128
FAULT MESSAGE
P21 stuck open. Run Auto/manual test.
Power Limited. Power circuit problem
RESTRICTIONS
Reference power is reduced by 1/6 times of such faults while motoring
in 6P mode.
Dynamic brake prohibited.
ALARM BELL
5 seconds
RESET LEVEL
Low, Manual
After manual reset if the fault still present, the fault will be generated
again.
FAULT
Automatic when P21 power contactor closes.
RECOVERY
PROBABLE
1. Defective power contactor.
CAUSES
2. Bad wiring.
3. Slackness in connector of cable ID: AY at MEP-660.
4. Defective digital output card MLSD 16 in slot 14.
5. Slackness in connector of cable ID: AU at MEP-660
6. Defective digital input card MDIP 16 in slot 10.
FAULT
This fault will be logged due to delayed / sluggish operation of power
ISOLATION
contactors. The fault may not exist while troubleshooting. In such case
check and ensure that the power contactor is operating freely and the
auxiliary contact is having sufficient over travel and pressure.
1.
Check and ensure control air pressure is 5Kg./Sq.Cm. If control air
pressure is less/excess adjust to 5Kg./Sq./Cm.
2.
Operate the power contactor manually by pressing armature plate
of the magnet valve.
3.
If the power contactor is not operating:
A. Defective pneumatic pipeline. Check and replace the pipeline.
B. Defective magnet valve. Check and replace.
C. Defective power contactor. Check and replace.
4.
If the power contactor is operating, set up the display to ‘Manual
Test for Outputs’ under ‘Test Mode’ menu option.
5.
Enter 1 and press ‘Enter’ key to test P21 power contactor operation.
6.
Press 1 to energise the P21 contactor.
7.
If P21 is not picking up, check voltage at the power contactor
magnet valve terminals.
A. If the voltage is more than 65V, magnet valve coil is defective.
Replace the magnet valve.
8.
If the voltage is zero, check voltage at coil terminal (wire 13) with
respect to locomotive 4 wire.
A. If the voltage is zero, check the continuity of 13-wire loop
coming to magnet valve coil. Check and replace open circuited
wire/wrong connection.
9.
If the voltage is more than 60 V, Check the supply voltage between
loco wire 50 and magnet valve coil terminal P21CL.
A. If voltage is zero, there is no continuity of wire P21CL from MEP-
660 to magnet valve.
a) Check slackness of connector of (Cable ID: AY) at MEP-660. If
slack tighten the connector.
b) Check the continuity of P21CL wire from MEP-660 to magnet
128
valve coil terminal (Cable ID: AY, Pin-B). If necessary replace
the cable.
c) If the continuity is good and there is no slackness in
connector, then the digital output card MLSD 16 in slot No. 14
is defective. Replace the card.
10. If P21 is picking up, check the status of Green LED 4 on the digital
input card 2 in slot 10.
11. If the Green LED 4 is not glowing, check supply Voltage at auxiliary
contact (wire No. 51) with respect to locomotive 4 wire.
A. If voltage is zero, check the continuity of 51-wire loop coming to
P21 power contactor auxiliary contact.
12. If voltage is more than 65V, then check voltage at auxiliary contact
(wire no. P21FB) with respect to locomotive 4 wire.
A. If voltage is zero, the auxiliary contact is bad. Replace the
auxiliary contacts.
13. If voltage is more than 60 V,
a) Check the slackness of connector of cable ID: AU at MEP-660.
If slack tighten and check the LED status.
b) Check the continuity of Wire P21FB from P21 power contactor
to MEP-660. (Cable ID: AU, Pin-E). If necessary replace the
cable.
14. If the Green LED 4 is glowing:
A. Check the status of corresponding Yellow LED on the same card.
B. If the yellow LED is not glowing, then the digital input card MDIP
16 in slot No. 10 is defective. Replace the card and check.
15. If Both Green and Yellow LEDs 4 are glowing on the digital input
card MDIP 16 in slot 10, the feed back status should be displayed
ON. Toggle the P21 contactor operation two to three times and
ensure the feedback signal is changing accordingly.
129
PARAMETER
DESCRIPTION
FAULT CODE
1129
FAULT MESSAGE
P31 stuck open. Run Auto/manual test.
Power Limited. Power circuit problem
RESTRICTIONS
Reference power is reduced by 1/3 times of such faults while motoring
in 6P mode.
Dynamic brake prohibited.
ALARM BELL
5 seconds
RESET LEVEL
Low, Manual
After manual reset if the fault still present, the fault will be generated
again.
FAULT
Automatic when P31 power contactor closes.
RECOVERY
PROBABLE
1. Defective power contactor.
CAUSES
2. Bad wiring.
3. Slackness in connector of cable ID: AY at MEP-660.
4. Defective digital output card MLSD 16 in slot 14.
5. Slackness in connector of cable ID: AU at MEP-660
6. Defective digital input card MDIP 16 in slot 10.
FAULT
This fault will be logged due to delayed / sluggish operation of power
ISOLATION
contactors. The fault may not exist while troubleshooting. In such case
check and ensure that the power contactor is operating freely and the
auxiliary contact is having sufficient over travel and pressure.
1.
Check and ensure control air pressure is 5Kg./Sq.Cm. If control air
pressure is less/excess adjust to 5Kg./Sq./Cm.
2.
Operate the power contactor manually by pressing armature plate
of the magnet valve.
3.
If the power contactor is not operating:
A. Defective pneumatic pipeline. Check and replace the pipeline.
B. Defective magnet valve. Check and replace.
C. Defective power contactor. Check and replace.
4.
If the power contactor is operating, set up the display to ‘Manual
Test for Outputs’ under ‘Test Mode’ menu option.
5.
Enter 2 and press ‘Enter’ key to test P31 power contactor operation.
6.
Press 1 to energise the P31 contactor.
7.
If P31 is not picking up, check voltage at the power contactor
magnet valve terminals.
A. If the voltage is more than 65V, magnet valve coil is defective.
Replace the magnet valve.
8.
If the voltage is zero, check voltage at coil terminal (wire 13) with
respect to locomotive 4 wire.
A. If the voltage is zero, check the continuity of 13-wire loop
coming to magnet valve coil. Check and replace open circuited
wire/wrong connection.
9.
If the voltage is more than 60 V, Check the supply voltage between
loco wire 50 and magnet valve coil terminal P31CL.
A. If voltage is zero, there is no continuity of wire P31CL from MEP-
660 to magnet valve.
a) Check slackness of connector of (Cable ID: AY) at MEP-660. If
slack tighten the connector.
b) Check the continuity of P31CL wire from MEP-660 to magnet
130
valve coil terminal (Cable ID: AY, Pin-C). If necessary replace
the cable.
c) If the continuity is good and there is no slackness in
connector, then the digital output card MLSD 16 in slot No. 14
is defective. Replace the card.
10. If P31 is picking up, check the status of Green LED 5 on the digital
input card 2 in slot 10.
11. If the Green LED 5 is not glowing, check supply Voltage at auxiliary
contact (wire No. 51) with respect to locomotive 4 wire.
A. If voltage is zero, check the continuity of 51-wire loop coming to
P31 power contactor auxiliary contact.
12. If voltage is more than 65V, then check voltage at auxiliary contact
(wire no. P31FB) with respect to locomotive 4 wire.
A. If voltage is zero, the auxiliary contact is bad. Replace the
auxiliary contacts.
13. If voltage is more than 60V,
A. Check the slackness of connector of cable ID: AU at MEP-660. If
slack tighten and check the LED status.
B. Check the continuity of Wire P31FB from P31 power contactor to
MEP-660. (Cable ID: AU, Pin-F). If necessary replace the cable.
14. If the Green LED 5 is glowing:
A. Check the status of corresponding Yellow LED on the same card.
B. If the yellow LED is not glowing, then the digital input card MDIP
16 in slot No. 10 is defective. Replace the card and check.
15. If Both Green and Yellow LEDs 5 are glowing on the digital input
card MDIP 16 in slot 10, the feed back status should be displayed
ON. Toggle the P31 contactor operation two to three times and
ensure the feedback signal is changing accordingly.
131
PARAMETER
DESCRIPTION
FAULT CODE
1130
FAULT MESSAGE
P2 stuck open. Run Auto/manual test.
Power Limited. Power circuit problem
RESTRICTIONS
Reference power is reduced by 1/6 times of such faults while motoring
in 6P mode.
ALARM BELL
5 seconds
RESET LEVEL
Low, Manual
After manual reset if the fault still present, the fault will be generated
again.
FAULT
Automatic when P2 power contactor closes.
RECOVERY
PROBABLE
1. Defective power contactor.
CAUSES
2. Bad wiring.
3. Slackness in connector of cable ID: AY at MEP-660.
4. Defective digital output card MLSD 16 in slot 14.
5. Slackness in connector of cable ID: AU at MEP-660
6. Defective digital input card MDIP 16 in slot 10.
FAULT
This fault will be logged due to delayed / sluggish operation of power
ISOLATION
contactors. The fault may not exist while troubleshooting. In such case
check and ensure that the power contactor is operating freely and the
auxiliary contact is having sufficient over travel and pressure.
1.
Check and ensure control air pressure is 5Kg./Sq.Cm. If control air
pressure is less/excess adjust to 5Kg./Sq./Cm.
2.
Operate the power contactor manually by pressing armature plate
of the magnet valve.
3.
If the power contactor is not operating:
A. Defective pneumatic pipeline. Check and replace the pipeline.
B. Defective magnet valve. Check and replace.
C. Defective power contactor. Check and replace.
4.
If the power contactor is operating, set up the display to ‘Manual
Test for Outputs’ under ‘Test Mode’ menu option.
5.
Enter 3 and press ‘Enter’ key to test P2 power contactor operation.
6.
Press 1 to energise the P2 contactor.
7.
If P2 is not picking up, check voltage at the power contactor
magnet valve terminals.
A. If the voltage is more than 65V, magnet valve coil is defective.
Replace the magnet valve.
8.
If the voltage is zero, check voltage at coil terminal (wire 13) with
respect to locomotive 4 wire.
A. If the voltage is zero, check the continuity of 13-wire loop
coming to magnet valve coil. Check and replace open circuited
wire/wrong connection.
9.
If the voltage is more than 60 V, Check the supply voltage between
loco wire 50 and magnet valve coil terminal P2CL.
A. If voltage is zero, there is no continuity of wire P2CL from MEP-
660 to magnet valve.
a) Check slackness of connector of (Cable ID: AY) at MEP-660. If
slack tighten the connector.
b) Check the continuity of P2CL wire from MEP-660 to magnet
valve coil terminal (Cable ID: AY, Pin-D). If necessary replace
132
the cable.
c) If the continuity is good and there is no slackness in
connector, then the digital output card MLSD 16 in slot No. 14
is defective. Replace the card.
10. If P2 is picking up, check the status of Green LED 6 on the digital
input card 2 in slot 10.
11. If the Green LED 6 is not glowing, check supply Voltage at auxiliary
contact (wire No. 51) with respect to locomotive 4 wire.
A. If voltage is zero, check the continuity of 51-wire loop coming to
P2 power contactor auxiliary contact.
12. If voltage is more than 65V, then check voltage at auxiliary contact
(wire no. P2FB) with respect to locomotive 4 wire.
A. If voltage is zero, the auxiliary contact is bad. Replace the
auxiliary contacts.
13. If voltage is more than 60 V,
A. Check the slackness of connector of cable ID: AU at MEP-660. If
slack tighten and check the LED status.
B. Check the continuity of Wire P2FB from P2 power contactor to
MEP-660. (Cable ID: AU, Pin-G). If necessary replace the cable.
14. If the Green LED 6 is glowing:
A. Check the status of corresponding Yellow LED on the same card.
B. If the yellow LED is not glowing, then the digital input card MDIP
16 in slot No. 10 is defective. Replace the card and check.
15. If Both Green and Yellow LEDs 6 are glowing on the digital input
card MDIP 16 in slot 10, the feed back status should be displayed
ON. Toggle the P2 contactor operation two to three times and
ensure the feedback signal is changing accordingly.
133
PARAMETER
DESCRIPTION
FAULT CODE
1131
FAULT MESSAGE
P22 stuck open. Run Auto/manual test.
Power Limited. Power circuit problem
RESTRICTIONS
Reference power is reduced by 1/6 times of such faults while motoring
in 6P mode.
ALARM BELL
5 seconds
RESET LEVEL
Low, Manual
After manual reset if the fault still present, the fault will be generated
again.
FAULT
Automatic when P22 power contactor closes.
RECOVERY
PROBABLE
1. Defective power contactor.
CAUSES
2. Bad wiring.
3. Slackness in connector of cable ID: AY at MEP-660.
4. Defective digital output card MLSD 16 in slot 14.
5. Slackness in connector of cable ID: AU at MEP-660
6. Defective digital input card MDIP 16 in slot 10.
FAULT
This fault will be logged due to delayed / sluggish operation of power
ISOLATION
contactors. The fault may not exist while troubleshooting. In such case
check and ensure that the power contactor is operating freely and the
auxiliary contact is having sufficient over travel and pressure.
1.
Check and ensure control air pressure is 5Kg./Sq.Cm. If control air
pressure is less/excess adjust to 5Kg./Sq./Cm.
2.
Operate the power contactor manually by pressing armature plate
of the magnet valve.
3.
If the power contactor is not operating:
A. Defective pneumatic pipeline. Check and replace the pipeline.
B. Defective magnet valve. Check and replace.
C. Defective power contactor. Check and replace.
4.
If the power contactor is operating, set up the display to ‘Manual
Test for Outputs’ under ‘Test Mode’ menu option.
5.
Enter 4 and press ‘Enter’ key to test P22 power contactor operation.
6.
Press 1 to energise the P22 contactor.
7.
If P22 is not picking up, check voltage at the power contactor
magnet valve terminals.
A. If the voltage is more than 65V, magnet valve coil is defective.
Replace the magnet valve.
8.
If the voltage is zero, check voltage at coil terminal (wire 13) with
respect to locomotive 4 wire.
A. If the voltage is zero, check the continuity of 13-wire loop
coming to magnet valve coil. Check and replace open circuited
wire/wrong connection.
9.
If the voltage is more than 60 V, Check the supply voltage between
loco wire 50 and magnet valve coil terminal P22CL.
A. If voltage is zero, there is no continuity of wire P22CL from MEP-
660 to magnet valve.
a) Check slackness of connector of (Cable ID: AY) at MEP-660. If
slack tighten the connector.
b) Check the continuity of P22CL wire from MEP-660 to magnet
134
valve coil terminal (Cable ID: AY, Pin-E). If necessary replace
the cable.
c) If the continuity is good and there is no slackness in
connector, then the digital output card MLSD 16 in slot No. 14
is defective. Replace the card.
10. If P22 is picking up, check the status of Green LED 7 on the digital
input card 2 in slot 10.
11. If the Green LED 7 is not glowing, check supply Voltage at auxiliary
contact (wire No. 51) with respect to locomotive 4 wire.
A. If voltage is zero, check the continuity of 51-wire loop coming to
P22 power contactor auxiliary contact.
12. If voltage is more than 65V, then check voltage at auxiliary contact
(wire no. P22FB) with respect to locomotive 4 wire.
A. If voltage is zero, the auxiliary contact is bad. Replace the
auxiliary contacts.
13. If voltage is more than 60 V,
A. Check the slackness of connector of cable ID: AU at MEP-660. If
slack tighten and check the LED status.
B. Check the continuity of Wire P22FB from P22 power contactor to
MEP-660. (Cable ID: AU, Pin-H). If necessary replace the cable.
14. If the Green LED 7 is glowing:
A. Check the status of corresponding Yellow LED on the same card.
B. If the yellow LED is not glowing, then the digital input card MDIP
16 in slot No. 10 is defective. Replace the card and check.
15. If Both Green and Yellow LEDs 7 are glowing on the digital input
card MDIP 16 in slot 10, the feed back status should be displayed
ON. Toggle the P22 contactor operation two to three times and
ensure the feedback signal is changing accordingly.
135
PARAMETER
DESCRIPTION
FAULT CODE
1132
FAULT MESSAGE
P32 stuck open. Run Auto/manual test.
Power Limited. Power circuit problem
RESTRICTIONS
Reference power is reduced by 1/6 times of such faults while motoring
in 6P mode.
Dynamic brake prohibited.
ALARM BELL
5 seconds
RESET LEVEL
Low, Manual
After manual reset if the fault still present, the fault will be generated
again.
FAULT
Automatic when P32 power contactor closes.
RECOVERY
PROBABLE
1. Defective power contactor.
CAUSES
2. Bad wiring.
3. Slackness in connector of cable ID: AY at MEP-660.
4. Defective digital output card MLSD 16 in slot 14.
5. Slackness in connector of cable ID: AU at MEP-660
6. Defective digital input card MDIP 16 in slot 10.
FAULT
This fault will be logged due to delayed / sluggish operation of power
ISOLATION
contactors. The fault may not exist while troubleshooting. In such case
check and ensure that the power contactor is operating freely and the
auxiliary contact is having sufficient over travel and pressure.
1.
Check and ensure control air pressure is 5Kg./Sq.Cm. If control air
pressure is less/excess adjust to 5Kg./Sq./Cm.
2.
Operate the power contactor manually by pressing armature plate
of the magnet valve.
3.
If the power contactor is not operating:
A. Defective pneumatic pipeline. Check and replace the pipeline.
B. Defective magnet valve. Check and replace.
C. Defective power contactor. Check and replace.
4.
If the power contactor is operating, set up the display to ‘Manual
Test for Outputs’ under ‘Test Mode’ menu option.
5.
Enter 5 and press ‘Enter’ key to test P32 power contactor operation.
6.
Press 1 to energise the P32 contactor.
7.
If P32 is not picking up, check voltage at the power contactor
magnet valve terminals.
A. If the voltage is more than 65V, magnet valve coil is defective.
Replace the magnet valve.
8.
If the voltage is zero, check voltage at coil terminal (wire 13) with
respect to locomotive 4 wire.
A. If the voltage is zero, check the continuity of 13-wire loop
coming to magnet valve coil. Check and replace open circuited
wire/wrong connection.
9.
If the voltage is more than 60 V, Check the supply voltage between
loco wire 50 and magnet valve coil terminal P32CL.
A. If voltage is zero, there is no continuity of wire P32CL from MEP-
660 to magnet valve.
a) Check slackness of connector of (Cable ID: AY) at MEP-660. If
slack tighten the connector.
136
b) Check the continuity of P32CL wire from MEP-660 to magnet
valve coil terminal (Cable ID: AY, Pin-F). If necessary replace
the cable.
c) If the continuity is good and there is no slackness in
connector, then the digital output card MLSD 16 in slot No. 14
is defective. Replace the card.
10. If P32 is picking up, check the status of Green LED 8 on the digital
input card 2 in slot 10.
11. If the Green LED 8 is not glowing, check supply Voltage at auxiliary
contact (wire No. 51) with respect to locomotive 4 wire.
A. If voltage is zero, check the continuity of 51-wire loop coming to
P32 power contactor auxiliary contact.
12. If voltage is more than 65V, then check voltage at auxiliary contact
(wire no. P32FB) with respect to locomotive 4 wire.
A. If voltage is zero, the auxiliary contact is bad. Replace the
auxiliary contacts.
13. If voltage is more than 60 V,
A. Check the slackness of connector of cable ID: AU at MEP-660. If
slack tighten and check the LED status.
B. Check the continuity of Wire P32FB from P32 power contactor to
MEP-660. (Cable ID: AU, Pin-J). If necessary replace the cable.
14. If the Green LED 8 is glowing:
A. Check the status of corresponding Yellow LED on the same card.
B. If the yellow LED is not glowing, then the digital input card MDIP
16 in slot No. 10 is defective. Replace the card and check.
15. If Both Green and Yellow LEDs 8 are glowing on the digital input
card MDIP 16 in slot 10, the feed back status should be displayed
ON. Toggle the P32 contactor operation two to three times and
ensure the feedback signal is changing accordingly.
137
PARAMETER
DESCRIPTION
FAULT CODE
1133
FAULT MESSAGE
EXPR circuit open. Run Auto / manual test
May not power up.
RESTRICTIONS
--
ALARM BELL
5 seconds
RESET LEVEL
Low, Manual
After manual reset if the fault still present, the fault will be generated
again.
FAULT
Automatic when EXPR circuit is detected as closed.
RECOVERY
PROBABLE
1. Defective EXPR relay
CAUSES
2. Defective wiring.
3. Slackness of Connector of cable at MEP-660 (Cable ID: AY)
4. Defective digital output card MLSD 16 in slot 14
5. Slackness of connector of cable at MEP-660 (cable ID: AV)
6. Defective digital input card MDIP 16 in slot 11.
FAULT
After cranking wait for two minutes and check the status of EXPR relay.
ISOLATION
1.
If EXPR relay is not picking up check the supply at EXPR relay coil
terminals.
A. If the voltage is more than 65V, and still the relay is not picking
up then the EXPR relay is defective. Replace the relay.
2.
If the voltage is zero, check the voltage at coil terminal (Wire-13)
with respect to locomotive 4 wire.
A. If the voltage is zero, check the continuity of 13-wire loop
coming to EXPR relay. If necessary replace the open circuited /
wrong connections.
3.
If voltage is more than 65V, check the voltage between locomotive
wire-50 and EXPR coil terminal (wire No. EXPRCL).
A. If the voltage is zero
a) Check slackness of connector of cable (Cable ID: AY) at MEP-
660. If the cable is slack tighten.
b) Check continuity of wire EXPRCL from EXPR coil terminal to
MEP-660 (Cable ID: AY Pin-S). If necessary replace the cable.
c) If continuity I good, then digital output card MLSD 16 in slot
No. 14 is defective.
4.
If the EXPR relay is picking up, check the status of Green LED 2 on
the digital input card MDIP 16 in slot No. 11.
5.
If LED is not glowing, check voltage at EXPR relay interlock terminal
(Wire No.51)
A. If voltage is zero, check the continuity of wire 51 coming to
EXPR relay interlock. If necessary replace open circuited / wrong
connections.
6.
If voltage is more than 65V, check the voltage between locomotive
50 wire and EXPRFB wire at EXPR interlock terminal.
A. If the voltage is zero, the interlock contact is bad. Replace the
relay.
7.
If the voltage is more than 65V,
A. check the slackness of the connector of cable (Cable ID: AV) at
MEP-660. If cable connector is slack, tighten the connector.
B. If connector is tight, check the continuity of the wire EXPRFB
from EXPR relay interlock to MEP-660 (Cable ID: AV Pin-C). If
138
necessary replace the cable.
8. If the Green LED 2 is glowing and corresponding Yellow LED is not
glowing. The digital input card MDIP 16 in slot 11 is defective
replace the card and check once again.
9. Run ‘Auto test for Relays’ under ‘Test Mode’ menu option.
139
PARAMETER
DESCRIPTION
FAULT CODE
1134
FAULT MESSAGE
AGPR circuit open. Run Auto/manual test
Batteries may not charge.
RESTRICTIONS
--
ALARM BELL
5 seconds
RESET LEVEL
Low, Manual
After manual reset if the fault still present, the fault will be generated
again.
FAULT
Automatic when AGPR circuit is detected as closed.
RECOVERY
PROBABLE
1. Defective AGPR relay
CAUSES
2. Defective wiring.
3. Slackness of Connector of cable at MEP-660 (Cable ID: AZ)
4. Defective digital output card MLSD 16 in slot 14
5. Slackness of connector of cable at MEP-660 (cable ID: AV)
6. Defective digital input card MDIP 16 in slot 11
FAULT
After cranking wait for two minutes and check the status of AGPR
ISOLATION
relay.
1.
If AGPR relay is not picking up, check the supply at AGPR relay coil
terminals.
A. If the voltage is more than 65V, and still the relay is not picking
up then the AGPR relay is defective. Replace the relay.
2.
If the voltage is zero, check the voltage at coil terminal (Wire-13)
with respect to locomotive 4 wire.
A. If the voltage is zero, check the continuity of 13-wire loop
coming to AGPR relay. If necessary replace the open circuited /
wrong connections.
3.
If voltage is more than 65V, check the voltage between locomotive
50 wire and AGPR coil terminal (wire No. AGPRCL).
A. If the voltage is zero
a) Check slackness of connector of cable (Cable ID: AZ) at MEP-
660. If the cable is slack tighten.
b) Check continuity of wire AGPRCL from AGPR coil terminal to
MEP-660 (Cable ID: AZ Pin-D). If necessary replace the cable.
c) If continuity is good, then digital output card MLSD 16 in slot
No. 14 is defective.
4.
If the AGPR relay is picking up, check the status of Green LED 3 on
the digital input card MDIP 16 in slot No. 11.
5.
If LED 3 is not glowing, check voltage at AGPR relay interlock
terminal (Wire No.51)
A. If voltage is zero, check the continuity of wire 51 coming to
EXPR relay interlock. If necessary replace open circuited / wrong
connections.
6.
If voltage is more than 65V, check the voltage between locomotive
50 wire and AGPRFB wire at AGPR interlock terminal.
A. If the voltage is zero, the interlock contact is bad. Replace the
relay.
7.
If the voltage is more than 65V,
A. check the slackness of the connector of cable (Cable ID: AV) at
MEP-660. If cable connector is slack, tighten the connector.
140
B. If connector is tight, check the continuity of the wire AGPRFB
from EXPR relay interlock to MEP-660 (Cable ID: AV Pin-D). If
necessary replace the cable.
C. If the Green LED 3 is glowing and corresponding Yellow LED is
not glowing, the digital input card MDIP 16 in slot 11 is defective
replace the card and check once again.
8. Run ‘Auto test for Relays’ under ‘Test Mode’ menu option.
141
PARAMETER
DESCRIPTION
FAULT CODE
1135
FAULT MESSAGE
Wrong command. TL8 & TL0 High.
RESTRICTIONS
Cannot change direction
ALARM BELL
5 seconds
RESET LEVEL
Low, Manual
After manual reset if the fault still present, the fault will be generated
again.
FAULT
Automatic when one of the train lines status has become zero.
RECOVERY
PROBABLE
1. Defective interlocking of master controller allowing the RH to move
CAUSES
forward or reverse while the master handle is in notch / braking
zone.
2. Loco is being controlled from more than one source.
3. Defective wiring / jumper cable
Most probably this fault is of transient nature. The fault may not be
available at the time of investigation.
FAULT
1. If loco is coupled with another loco, remove the MU jumper cable.
ISOLATION
2. Shut down the engine while doing the following tests.
3. Check for proper mechanical interlocking of both control stands.
Reverser Handle should not move when the master handle /
selector handle is set to notch / brake position. If so replace the
defective master controller.
4. Keep both the reverser handles in neutral position.
5. Check the status of Green LEDs 0 & 1 on the digital input card MDIP
16 in slot 9.
6. If either Green LED 0 or Green LED 1 is glowing, then defective
wiring. Identify which wire is getting wrong supply and isolate.
7. If both Green LEDs are OFF.
8. Apply loco brakes and ensure loco brakes are physically applied.
9. Set the Reverser Handle to Forward direction on Short hood control
stand.
10. Move the master handle to Notch 1 and switch ON both GF
switches.
11. Green LED 0 and Green LED 7 should glow on the digital input card
MDIP 16 in slot 9 and corresponding yellow LEDs also should glow.
12. Green LED 1 yellow LED 1 should be OFF.
13. Set the master handle to IDLE, RH to reverse direction and open
the notch to 1.
14. Green LED 0 should go off and Green LED 1 should glow.
15. Repeat the test on the other control stand.
142
PARAMETER
DESCRIPTION
FAULT CODE
1136
FAULT MESSAGE
BKT Stuck in Motoring. Run Auto/Manual Test
Can't Brake: Electrical Control Problem
RESTRICTIONS
Dynamic Brake Prohibited
ALARM BELL
5 Sec.
RESET LEVEL
Low, Manual
After manual reset if the fault still present, the fault will be generated
again.
FAULT
Automatic when BKT stuck is cleared
RECOVERY
PROBABLE
1.
BKT not operating physically to braking side.
CAUSES
2.
BKT not operating to braking side due to magnet valve defective.
3.
BKT not operating to braking side due to no supply to magnet
valve.
FAULT
1.
Check and adjust control air pressure to 5Kgs./Sq.Cm.
ISOLATION
2.
Manually operate BKT magnet valves to change the BKT position
between braking and motoring.
3.
BKT contacts should change their position freely with out any
obstruction. Ensure the status of the Green LEDs 12 & 13 on the
digital input card MDIP16 in slot no.10 toggles with respect to BKT
position.
4.
If the BKT is not changing its position with manual operation of
magnet valves:
A. Check the Air hose connection to magnet valve. If air is leaking
or the pipe is blocked, change the air hose connection.
B. Press the armature plate of the magnet valve and check for any
Air leaking from the Air cylinder gasket / piston packing. If air is
leaking, change the gasket / piston packing.
C. Check free operation of Paul assembly by operating the BKT
with ‘L’ rod. If the BKT is not operating with normal force
change the pawl assembly.
5.
If the BKT is operating manually, set the BKT in motoring position
by manually operating the magnet valve.
6.
Set the display mode to ‘Manual Test for Outputs’ under ‘Test Mode’
menu.
A. Enter 10 and press ‘Enter’ key to test the BKT braking Magnet
valve.
B. Press ‘1’ key to operate the BKT-B magnet valve.
7.
If the BKT is not operating to braking side:
A. Check the voltage at the magnet valve coil terminals.
B. If voltage is more than 65 V, operating coil of the magnet valve
is defective. Replace the magnet valve.
C. If the voltage is zero, check the voltage at magnet valve coil
terminal (wire No. 13) with respective to locomotive 4 wire.
a) If the voltage is zero, check the continuity of 13-wire loop
connected to magnet valve. If necessary replace the open
circuited / wrong wiring.
b) If the voltage is more than 60 V, check the voltage at magnet
valve coil terminal (wire No. BKBCL) with respect to
locomotive 50 wire.
1) If the voltage is zero, then the connector at MEP-660 is
143
slack (cable ID: AY). Tighten the connector and check the
voltage again.
2) If voltage is still zero, check the continuity of BKBCL wire
from the magnet valve to MEP-660 (Cable ID: Pin No.L). If
necessary replace the cable and check the voltage once
again.
3) If voltage is still zero, then the digital output card MLSD 16
in slot No.14 defective. Replace the card.
8. Repeat the test again vide item No.6 and ensure BKT is throwing to
braking side
144
PARAMETER
DESCRIPTION
FAULT CODE
1137
FAULT MESSAGE
BKT-B Aux. Contact ckt. Open. Run Auto/Manual Test Can’t Brake:
Electrical Control Problem.
RESTRICTIONS
Dynamic Brake Prohibited
ALARM BELL
5 Sec.
RESET LEVEL
Low, Manual
After manual reset if the fault still present, the fault will be generated
again.
FAULT
Automatic when BKT-B Aux. Contact is closed.
RECOVERY
PROBABLE
1.
Low control air pressure causing sluggish operations of BKT.
CAUSES
2.
BKT partially moved and stopped.
3.
BKT-B auxiliary contact is bad.
4.
Defective wiring.
5.
Connector at MEP-660 (DI 16-DI 31) is slack
6.
Digital input card MDIP 16 in slot No. 10 defective.
FAULT
1.
Check and adjust control air pressure to 5Kgs./Sq.Cm.
ISOLATION
2.
Manually operate BKT magnet valves to change the BKT position
between braking and motoring.
3.
BKT contact should change their position freely with out any
obstruction. Ensure the status of the Green LEDs 12 & 13 on the
digital input card MDIP16 in slot no.10 toggles with respect to BKT
position.
4.
If the BKT is moving towards Braking position and stopping in
between:
A. Check the Air hose connection to magnet valve. If air is leaking
or the pipe is blocked, change the air hose connection.
B. Press the armature plate of the magnet valve and check for any
Air leaking from the Magnet valve / Air cylinder gasket / piston
packing. If air is leaking, change the magnet valve / gasket /
piston packing.
C. Check free operation of Paul assembly by operating the BKT
with ‘L’ rod. If the BKT is not operating with normal force
change the pawl assembly.
5.
If the BKT is operating manually:
6.
Check the BKT-B auxiliary contact for proper operation.
7.
If the contact is properly closing in braking side and still the fault is
logged:
A. Set the display mode to ‘Manual Test for Inputs’ under Test
mode Menu.
B. Key in 28 + ‘Enter’ key to test the status of the BKT-B feed
back.
C. Manually operate the BKT-B feedback auxiliary contact to make
and break the contact.
D. Observe the status of the Green LED 12 on the Digital input card
MDIP 16 in slot 10 and feed back position status on the display
unit.
E. The Green LED and the status on the display unit should toggle
as per the auxiliary contact position. LED should glow with
contact closed and status on display unit should be ON.
8.
If Green LED and the status on display unit are not toggling as per
145
the contact position
A. Check the voltage at BKT-Auxiliary contact wire No. 51 with
respect to Locomotive 4 wire.
B. If the Voltage is zero, check the continuity of 51-wire loop
connecting to BKT-B auxiliary contact. Identify the open
circuited wire/ wrong connection and rectify.
C. If the voltage is more than 65V, check the voltage at auxiliary
contact wire No. BKBFB with respect to locomotive 4 wire.
D. If the voltage is zero, then the contact is bad. Adjust / replace
the auxiliary contact.
E. If the voltage is more than 65V:
a) The cable (ID: AU) connector might be slack at MEP660
control unit.
b) Check the continuity of the wire BKBFB from BKT Auxiliary
contact to MEP660. If necessary replace the cable.
9. Check the BKT braking magnet valve operation once again and
ensure the BKT feed back signals are toggling correctly.
146
PARAMETER
DESCRIPTION
FAULT CODE
1138
FAULT MESSAGE
Direction reversal attempted at High Speed. Can’t Change Direction
RESTRICTIONS
Motoring and Dynamic Brake Prohibited
ALARM BELL
5 Sec.
RESET LEVEL
Low, Manual
After manual reset if the fault still present, the fault will be generated
again.
FAULT
Automatic when loco speed reduces to 2 KMs below the set speed for
RECOVERY
direction change.
PROBABLE
Most probably this problem occurs while the loco is n shunting service.
CAUSES
1. Driver might have attempted to reverse the direction of movement
even though the loco speed is more than 5 KMPh.
2.
0/8 wires might be getting wrong feed through another loco in MU.
FAULT
1. Check the data pack for the fault logged.
ISOLATION
2. Check the status of 0 and 8 wires supply and locomotive speed.
3. If no attempt of directional reverse is noticed,
4. Crank the engine and the loco for forward movement.
5. Check the status of Green LEDs 0 and 1 on the MDIP 16 card in slot
9
6. Only one green LED and corresponding yellow LED should glow at
one direction.
7. If both Green LEDs are glowing, wiring problem. Identify the wrong
feed and rectify.
8. If only one green LED and both yellow LEDs are glowing, then the
Digital input card MDIP 16 in slot No. 9 is defective. Replace the
card and check once again.
147
PARAMETER
DESCRIPTION
FAULT CODE
1139
FAULT MESSAGE
Invalid Notch Command. Running at IDLE/Notch 1
RESTRICTIONS
Engine speed is brought to IDLE
ALARM BELL
5 Sec.
RESET LEVEL
Low, Manual
After manual reset if the fault still present, the fault will be generated
again.
FAULT
Automatic when valid combination of TL wires 15, 12, 7, and 3 are
RECOVERY
energized.
PROBABLE
1.
This message is logged when an invalid combination of train line
CAUSES
wires 15, 12, 7 and 3 are fed to MEP-660.
2.
Wrong MU feeding
3.
Defective master controller
4.
Defective wiring between CS, TB and MU
5.
Defective Digital input card.
FAULT
1.
Ensure there is no MU cable connected to another loco
ISOLATION
2.
Set both master controllers in IDLE position and ensure brake
system is working normal.
3.
Check the status of Green and Yellow LEDs 2, 3, 4 and 5 on the
digital input card MDIP 16 in slot No. 9.
A. If any of the above said Green LEDs is glowing, wrong feed is
coming to that particular Tail Line wire.
a) Check the voltage at the backside terminal board. Identify
from where the voltage is coming and rectify.
B. If any of the above said yellow LEDs is glowing, then the digital
input card is defective. Replace the card and check up.
4.
Set the display mode to ‘Manual Test for Inputs’ under ‘Test Mode’
menu.
5.
Keep any of the master controller handle in steps from notch 1 to
8.
6.
Observe the status the both Green and Yellow LEDs 2, 3, 4 and 5
on the digital input card MDIP 16 in slot 9.
7.
The status of the LEDs should toggle as per the notch and sequence
given below.
Notch
TL wire 15
TL wire 12
TL wire 7
TL wire 3
Green LED 2
Green LED 3
Green LED 4
Green LED 5
1
2
3
4
5
6
7
8
* Indicate LED should glow.
8. If any of the Green LEDs is not glowing as per the sequence, it
indicates that particular wire is not energized.
9. Change the master controller and check weather the same LED is
not glowing in the same sequence.
148
10. If the Green LEDs are glowing normal as per the sequence, the
previous master controller is defective. Change the master
controller.
11. If the same Green LED is not glowing in sequence
A. Check the supply at the backside panel for particular train line
wire. Identify and rectify the wrong wiring.
B. Check the connector slackness of the cable ID: AT at the MEP-
660. If slack tighten.
C. Check the wire continuity from TB to the MEP-660. (Pin C = wire
15, Pin D= wire 12, Pin E = Wire 7 and Pin F = wire 3)
D. If necessary change the cable.
12. If the Green LEDs are glowing in correct sequence and Yellow LEDs
are not in sequence, the digital input card is defective. Replace the
card.
13. If both Green and yellow LEDs are glowing in correct sequence,
then the trouble might be with MU wiring/Cable. Identify and
rectify.
149
PARAMETER
DESCRIPTION
FAULT CODE
1140
FAULT MESSAGE
Cranking Contactor Stuck Open. Engine may not Crank.
RESTRICTIONS
--
ALARM BELL
5 Sec.
RESET LEVEL
Low, Manual
After manual reset if the fault still present, the fault will be generated
again.
FAULT
Automatic when CK1/CK2/CK3 auxiliary contacts open.
RECOVERY
PROBABLE
1. Defective CKC contactor
CAUSES
2. Defective output card MLSD 16 card in slot 14.
3. Connector of cable ID: AY is slack at MEP-660
4. Defective wiring
5. Defective cranking contactor
6. Defective digital input card MDIP 16 in slot 10
FAULT
This message will be logged during cranking only.
ISOLATION
1.
Open the battery knife switch.
2.
Manually operate and check free operation of CKC contactor and all
the three cranking contactors. Ensure there is no mechanical
obstruction to operate.
3.
Ensure that both Green and Yellow LEDs 0, 1 and 2 on the digital
input card MDIP 16 in slot 10 are glowing.
4.
If all the three LEDs are glowing:
A. Manually open the Auxiliary contacts of CK1, Ck2 and CK3.
B. Corresponding Green and Yellow LED should go off.
C. If corresponding LED is not going OFF,
a) Check the supply voltage on the corresponding feed back wire
(CK1FB/CK2FB/CK3FB) with respective to locomotive 4 wire.
b) If the supply is zero while the auxiliary contact is opened
manually and still the Green/Yellow LED is glowing, then the
digital input card MDIP 16 card in slot 10 is defective. Replace
the card.
c) If the supply voltage is more than 65V, then wiring mistake.
Identify from where the supply is feeding and rectify.
5.
Close the battery knife switch and prepare the loco for cranking.
6.
Pack the CK1, CK2, and CK3 contacts with an insulating sheet so
that auxiliary contacts open when they operate and no battery
supply is going to Aux. Machines.
7.
Press start button.
8.
CKC should pick up.
9.
If CKC is not picking up.
A. Check the voltage at the operating coil of CKC.
B. If the voltage is more than 65 Volts and still CKC is not picking
up, then CKC is defective. Replace the CKC.
C. If the voltage is zero, then check the voltage at wire No. 71 with
respect loco wire No. 4.
D. If the voltage is zero check the wire continuity of wire 71
connected to CKC coil.
E. If the Voltage is more than 65 volts at wire 71, then check the
voltage between loco wire 13 and wire CKCCL at CKC coil.
F. If the voltage is zero,
150
a) Connector of the cable ID: AY is slack at MEP-660. Tighten
the connector.
b) Check the continuity of wire CKCCL from CKC coil to MEP660.
(Pin-R, Cable: AY) if necessary replace the cable.
c) The digital output card MLSD 16 in slot 14 is defective.
Replace the card and check up.
10. If CKC is picking up and none of the CK contactors picking up, then
the main contacts of the CKC are bad. Change the contactor and
check up.
11. If CKC is picking up and any one of the three CK contactors is not
picking up, then it is a wiring mistake. Identify and rectify.
151
PARAMETER
DESCRIPTION
FAULT CODE
1141
FAULT MESSAGE
Aux. Gen. Output Voltage High FAULT
RESTRICTIONS
Battery charging
ALARM BELL
5 Sec.
RESET LEVEL
Medium, Manual
After manual reset if the fault still present, the fault will be generated
again.
FAULT
Automatic when Aux. Gen. Voltage is reduced.
RECOVERY
Automatic fault reset is permitted for 3 times in an Hour. After that
manual reset is required.
PROBABLE
1. Defective Aux. Generator due direct short of field wire with
CAUSES
Armature.
2. Defective MPWM2 card
3. Defective AGD / wiring
4. Defective Aux. Gen. Voltage sensor.
5. Defective MAIP8_AU card (Analog input card of Aux. Unit) in slot 1
6. Defective MAUCC card (Aux. Unit Control card) in slot No. 3
FAULT
1. Check the wiring of he Auxiliary machines. Ensure there is no short
ISOLATION
between LSS (A) and LAA terminals.
2. Ensure AGD wiring connections are intact.
3. Check the AGD with a multimeter for forward and reverse
resistance. If the diode is normal, reconnect the Wires back
before doing any test.
4. If the diode is showing open circuited on both sides, replace the
AGD.
5. Set the display mode to ‘Auxiliary’ under display mode.
6. If Au. Gen. Field current (AGFI) is high and APWM value is less,
then the MPWM2 card might be defective. Replace the card and
check.
7. If AGFI is proportional to APWM value, measure voltage at LA and
LAA terminals of the Aux. Gen.
8. If the measured voltage is =72 V and lower than the displayed
AGAV value, then the AGAV voltage sensor is defective. Replace the
Voltage sensor and check again.
9. If all the values of AGFI, APWM, AGAV and battery charging is with
in the limits and still the fault is logged, MAIP8_AU card or MAUCC
card might be defective.
10. Replace the cards and check once again.
152
PARAMETER
DESCRIPTION
FAULT CODE
1142
FAULT MESSAGE
Battery Charging Current High FAULT.
RESTRICTIONS
Battery charging
ALARM BELL
5 Sec.
RESET LEVEL
Medium, Manual
After manual reset if the fault still present, the fault will be generated
again.
FAULT
Automatic when battery-charging current is reduced.
RECOVERY
Automatic fault reset is permitted for 3 times in an Hour. After that
manual reset is required.
PROBABLE
Most probably this message will be logged soon after cranking.
CAUSES
1. Defective batteries
2. Defective BATI
3. Defective Aux. Gen. with internal short of field to armature.
FAULT
1. Check the individual cell voltage and specific gravity. Replace the
ISOLATION
defective battery.
2. Check the battery charging current shown on the display and the
value shown on battery ammeter.
3. If display is showing abnormally more value, then the battery
charging current sensor (BATI) is bad.
4. Replace the sensor and check once again.
5. If the message is followed by ‘Aux. Gen. Voltage High Fault’ or
‘Aux. Gen. Output Over Current’ then check for the other faults.
153
PARAMETER
DESCRIPTION
FAULT CODE
1143
FAULT MESSAGE
Aux. Gen. Output Over current FAULT
RESTRICTIONS
Battery charging
ALARM BELL
5 Sec.
RESET LEVEL
Medium, Manual
After manual reset if the fault still present, the fault will be generated
again.
FAULT
Automatic when Aux. Gen. output current is reduced.
RECOVERY
Automatic fault reset is permitted for 3 times in an Hour. After that
manual reset is required.
PROBABLE
1. There may be a real high current due to short circuited load
CAUSES
2. Defective Aux. Generator due to direct short of field wire with
Armature.
3. Defective AGAI current sensor
4. Defective Aux. Gen. Voltage sensor.
5. Defective MAIP8_AU card (Analog input card of Aux. Unit) in slot 1
6. Defective MAUCC card (Aux. Unit Control card) in slot No. 3
FAULT
If the fault is logged soon after cranking, then it may due to deep
ISOLATION
discharge. The message may be ignored.
1. Set the display mode to ‘Auxiliary’ under ‘Display’ menu option.
2. If (AGAV) Aux. Gen Voltage is high but the AGFI is zero or normal:
A. Defective Aux. Gen. with a field short-circuited internally with
the armature.
B.
‘Aux. Gen Voltage High’ message will be logged.
3. If Battery charging current is high but AGAV voltage is normal:
A. It may be due to defective battery set. Check individual battery
voltage and specific gravity value and level. Replace the
defective battery. However the ‘Battery charging current High’
message will also be logged.
4. Measure and compare the Current flowing from Aux. Gen. with a
clamp on ammeter.
A. If both AGAI value on the display and clamp on ammeter are
same ad high, then there is a real over load. Identify and
rectify.
B. If the AGAI value is comparatively higher than the clamp on
ammeter, then AGAI is defective. Replace the sensor and check
again.
C. If both AGAI value and clamp on ammeter value are same and
the values are with in the set limit of AGAI and still the fault is
logged then the MAIP8_AU or MAUCC cards are defective.
Replace the cards and check again.
154
PARAMETER
DESCRIPTION
FAULT CODE
1144
FAULT MESSAGE
Aux. Gen. Field Over Current FAULT
RESTRICTIONS
Battery charging
ALARM BELL
5 Sec.
RESET LEVEL
Medium, Manual
After manual reset if the fault still present, the fault will be generated
again.
FAULT
Automatic when Aux. Gen. field current is reduced.
RECOVERY
Automatic fault reset is permitted for 3 times in an Hour. After that
manual reset is required.
PROBABLE
1.
External short circuit between AGC wire and 4 wire.
CAUSES
2.
Defective MPWM2 card.
3.
Defective (AGAV) Aux. Gen. Voltage sensor.
FAULT
1.
Set the display mode to ‘Auxiliary’ under ‘Display Mode’ menu.
ISOLATION
2.
Switch OFF AGFB breaker and Crank the engine.
3.
On the display APWM value should be zero.
4.
If AGFI is abnormally high, remove MPWM2 card from slot 18.
A. If AGFI is still showing high, there could be an external short
circuit bypassing PWM o/p (AGF) or the Aux. Gen. is defective.
a) Check up the short-circuited wires and replace. If necessary
replace the Aux. Gen.
B. If AGFI is zero after removing MPWM2 card, the MPWM2 card is
defective. Replace and check up.
5.
Switch ON AGFB. APWM and AGFI should rise slowly.
6.
If the fault still logged, check the Aux. Gen. Voltage AGAV.
7.
If AGAV is zero, measure the Aux. Gen. Voltage with a voltmeter at
the Aux. Gen. terminals.
A. If the Voltage is zero, there is an open circuit in the machine. A
fault message ‘Auxiliary Generator Output Circuit Open FAULT’
will also be logged. Check up with the machine.
8.
If the voltage at Aux. Gen. Terminals is 72V, measure the voltage
at AGAV voltage sensor input terminals.
A. If the voltage is zero, the wiring from Ax. Gen. To AGAV voltage
sensor is defective. Identify the open circuited leads and
replace.
9.
If the voltage at AGAV sensor terminals is 72V and AGAV is
showing zero, the AGAV sensor is defective.
A. Replace the AGAV sensor and check up.
155
PARAMETER
DESCRIPTION
FAULT CODE
1145
FAULT MESSAGE
Auxiliary Generator Output Circuit Open FAULT
No Battery Charging. Warning: Battery Life Limited. Loco may STALL.
RESTRICTIONS
Battery charging.
ALARM BELL
5 Sec.
RESET LEVEL
Low, Manual
After manual reset if the fault still present, the fault will be generated
again.
FAULT
Automatic when Aux. Gen. Out put circuit is detected as closed.
RECOVERY
PROBABLE
1. Defective wiring (Open circuited at Aux. Gen. TB or back side TB.)
CAUSES
2. Defective Aux. Gen.
3. Defective AGAI current sensor.
FAULT
1. Set the display mode to ‘Auxiliary’ under ‘Display Mode’ menu.
ISOLATION
2. Crank the engine and switch ON AGFB.
3. If AGFI is more than zero and aux. Gen. voltage is 72V and AGAI is
showing zero, then there is an external open circuit after the Aux.
Gen.
A. Check up terminals at the back side TB for any burnt / fused
terminals of the Aux. Gen.
B. Identify and replace the defective wiring.
4. If BATI is showing and AGAI is showing less than BATI then AGAI
current sensor is defective. Replace and check up
156
PARAMETER
DESCRIPTION
FAULT CODE
1146
FAULT MESSAGE
Aux. Gen. Field Circuit Open or Short.
No Battery Charging. Warning: Battery Life Limited. Loco may STALL.
RESTRICTIONS
Battery charging.
ALARM BELL
5 Sec.
RESET LEVEL
Low, Manual
After manual reset if the fault still present, the fault will be generated
again.
FAULT
Automatic when Aux. Gen. field circuit is closed.
RECOVERY
PROBABLE
1. Defective wiring (Open circuited at Aux. Gen. TB or back side TB.)
CAUSES
2. Defective AGFB
3. Bad interlocks of AGPR. (AGC-AGD, AGD-AGF)
4. Defective Aux. Gen. (Field is internally open circuited.)
5. Defective MPWM2 card.
FAULT
1. Set the display mode to ‘Auxiliary’ under ‘Display Mode’ menu.
ISOLATION
3. Crank the engine and switch ON AGFB.
4. If APWM is more than 0 and AGFI is zero,
5. Check voltage between wire 49 (at AGFB) and locomotive 4-wire.
A. If Voltage is zero, 49-wire loop coming to AGFB is open
circuited. Identify and replace.
6. If the voltage is more than 65V, check Voltage between wire-49B at
AGFB breaker and locomotive 4-wire.
A. If voltage is 0 with AGFB in ON position then the AGFB is
defective. Replace the AGFB.
7. If the voltage between wire- 49B at AGFB and locomotive 4-wire is
more than 65V, check the voltage between wire-49B at backside TB
and locomotive 4-wire.
A. If the voltage is at backside TB (49B) is zero, the wire-49B from
AGFB to back side TB is open circuited. Replace the wire.
8. If the voltage at 49B (back side TB) is more than 65V, check the
voltage between wire LS at Aux. Gen. Terminal and locomotive 4-
wire.
A. If Voltage is 0, Wire-49B from backside TB to Aux. Gen. is open
circuited. Replace the wiring.
9. If voltage at LS (Aux. Gen. TB) is more than 65V
10. Switch off AGFB and disconnect the wire AGF which is going to
MEP-660 (Cable ID: AR) from the backside TB. Switch ON AGFB.
11. Check the voltage between wire-LSS at Aux. Gen. TB and
locomotive 4-wire.
A. If Voltage is 0, Aux. Gen. field open circuited internally. Check
and replace the Aux. Gen.
12. If Voltage at LSS (Aux. Gen. TB) is more than 65V, Check the
voltage between wire LSS at AGFI current sensor and locomotive 4
wire.
A. If the Voltage is zero, the wire LSS from Aux. Gen. TB to AGFI
current sensor is open circuited.
13. If the Voltage ay wire LSS (AGFI) is more than 65V, check the
voltage between wire AGC at AGFI current sensor and locmotive 4-
wire.
A. If the voltage is 0, the AGFI current sensor is defective. Replace
157
the AGFI current sensor.
14. If voltage at AGC (AGFI) is more than 65V, check the voltage AGF
backside TB and locomotive 4 wire.
A. If the voltage is zero,
a) Wire-AGC from AGFI to AGPR interlock is open circuited.
Check and replace.
b) AGPR interlocks bad. Replace the AGPR relay.
c) Wire-AGF from AGPR interlock and backside TB is open
circuited. Check and replace.
15. If voltage at wire AGF at the backside TB is more than 65V,
A. Check the slackness of the connecter of cable ID: AR at MEP660.
If slack tighten.
B. Check the continuity of wire AGF from TB to connector of cable
ID: AR, Pin - C. If necessary replace the cable.
C. Switch off AGFB and reconnect the AGF wire to backside TB.
Switch ON AGFB.
16. If still AGFI is showing zero, MPWM2 card might be defective.
Replace the card check up.
158
PARAMETER
DESCRIPTION
FAULT CODE
1147
FAULT MESSAGE
AUX EEPROM Faulty. All AUX Faults Cleared.
RESTRICTIONS
--
ALARM BELL
--
RESET LEVEL
HIGH, Manual
FAULT
--
RECOVERY
PROBABLE
System detected fault while writing the faults on EEPROM
CAUSES
FAULT
--
ISOLATION
PARAMETER
DESCRIPTION
FAULT CODE
1149
FAULT MESSAGE
VCD Stuck Closed. Run Auto/manual Test
May Not Apply Alerter Brake
RESTRICTIONS
--
ALARM BELL
5 sec.
RESET LEVEL
LOW, Manual
If the fault condition is still present even when cleared manually, the
fault will be generated again.
FAULT
Automatic when VCDR auxiliary contact is open.
RECOVERY
PROBABLE
This fault is logged when the relay VCDR is defective or VCDR feed
CAUSES
back interlock wiring is short-circuited.
FAULT
1. Shutdown the engine. Switch ON MB1, MB2 and MPCB breakers
ISOLATION
only. Check the status of the VCDR relay.
2. If the relay is in energized position, check the supply across the
relay coil.
A. If the voltage is zero but relay energised, then the relay is
defective. Replace.
3. If the Voltage is more than 65 V, digital output card MLSD16 in slot
No. 15 is defective. Replace the card.
4. With the relay in de-energized position, check the status of Green
LED 11 on the digital input card MDIP 16 in slot no.12.
A. If both Greed LED 11 and corresponding yellow LED 11 are
glowing, wire No. VCDR FB is getting supply due
a) Faulty wiring. Check and rectify.
b) Relay VCDR is defective. Replace the relay.
Note: This Error message will be generated only if alerter relay is provided and “VCD
Enable” Flag and “VCD Relay Connected” flags are set.
159
PARAMETER
DESCRIPTION
FAULT CODE
1150
FAULT MESSAGE
VCD Circuit Open. Run Auto/Manual Test.
Alerter Brake might be applied. Loco may not move.
RESTRICTIONS
--
ALARM BELL
5 sec.
RESET LEVEL
LOW, Manual
If the fault condition is still present even when cleared manually, the
fault will be generated again.
FAULT
Automatic when VCDR auxiliary contact is closed.
RECOVERY
PROBABLE
1.
Defective relay VCDR.
CAUSES
2.
Defective wiring.
3.
Defective digital output card MLSD16 card
4.
Defective Digital Input card MDIP 16.
FAULT
1.
Crank the engine. Check the status of the relay VCDR.
ISOLATION
2.
If the relay is in de-energised position, check the voltage across the
operating coil of the VCDR.
A. If the voltage is more than 65V and relay not picking up, then
the relay is defective. Replace the relay.
3.
If the voltage is zero, check the voltage between wire-13 at the
VCDR coil terminal and locomotive 4 wire.
A. If the voltage is zero, check the continuity of wire 13 connected
to VCDR coil terminal. Identify the wrong wiring and replace.
4.
If the voltage at wire 13 (VCDR coil terminal) is more than 65V,
check the voltage between locomotive wire-13 and ALRR wire at the
coil terminal.
A. If the voltage is 0, there is no continuity of wire ALRR from
MEP660 to VCDR coil.
a) Check the slackness of the connector cable (ID: AZ) at the
MEP-660 control unit. If slack tighten the connector.
b) Check the continuity of the wire ALRR from the coil to
connector of cable ID: AZ, Pin No. K. If necessary replace
the cable.
c) If still relay is not energized, the MLSD 16/2 card in slot No.
15 defective. Replace the card and check up.
5.
If the relay is in energized position, check the status of Green LED
11 on the digital input card MDIP 16 in slot no.12.
6.
If Greed LED 11 is not glowing, check the voltage between wire 51
at the VCDR interlock and locomotive 4 wire.
A. If the voltage is 0, check the continuity of 51-wire loop. Identify
and replace the wrong wiring.
7.
If the voltage is more than 65V, check the voltage between wire
ALT at the VCDR interlock and locomotive 4 wire.
A. If the voltage is zero, then the relay interlock is bad. Replace
the relay.
8.
If the voltage is more than 65V,
A. Check the slackness of the cable (ID: AW) connector at the
MEP-660 control unit.
B. Check continuity of the wire ALT from ALRTRB relay interlock to
the connector Pin - M (ID: AW).
C. If necessary replace the cable and check.
160
D. If still green LED 11 is not glowing, MDIP 16 card might be
defective. Replace the card and check up.
9. If the Green LED 11 is glowing and corresponding Yellow LED is not
glowing, then also the MDIP 16 card is defective. Replace the card
and check up.
Note: This Error message will be generated only if alerter relay is provided and “VCD
Enable” Flag is set.
161
PARAMETER
DESCRIPTION
FAULT CODE
1151
FAULT MESSAGE
AFLR Stuck Closed. Run Auto/Manual Test. Flasher Light might not
glow if Train parting occurs.
RESTRICTIONS
--
ALARM BELL
5 sec.
RESET LEVEL
LOW, Manual
If the fault condition is still present even when cleared manually, the
fault will be generated again.
FAULT
Automatic when AFLR auxiliary contact is open.
RECOVERY
PROBABLE
1. Defective relay AFLR.
CAUSES
2. Defective wiring.
3. Defective digital output card MLSD16
FAULT
1. Switch ON circuit breakers MB1, MB2 breakers only and all other
ISOLATION
breakers in OFF position. Check the status of ALFR relay. The relay
should be in de-energised position.
2. If interlocks are in disturbed condition and Green LED 12 on the
digital input card MDIP16 in slot 12 is glowing replace the relay.
3. If the relay is in energized position, check the voltage across the
coil.
A. If the voltage is zero, but the relay is picked up position, then
relay is defective. Replace the relay.
B. If the voltage is more than 65V, then the MLSD16 card is
defective. Replace the card.
4. With the AFL relay in de-energised position, check the status of the
Green LED 12 on the digital input card MDIP16 in slot No. 12.
If the Green LED is glowing, AFLR FB wire is getting wrong supply
continuously. Check up wiring and rectify.
If the green LED 12 is not glowing, run self test for the relay ALFR
to verify the operation of relay interlocks.
Note: This Error message will be generated only if Auto Flasher relay is provided and
“Auto Flasher Enabled” Flag is set.
162
PARAMETER
DESCRIPTION
FAULT CODE
1152
FAULT MESSAGE
AFLR Circuit Open. Run Auto/Manual Test. Remove AFLR Relay to stop
Buzzer & Flasher Light glowing.
RESTRICTIONS
--
ALARM BELL
5 sec.
RESET LEVEL
LOW, Manual
If the fault condition is still present even when cleared manually, the
fault will be generated again.
FAULT
Automatic when AFLR auxiliary contact is closed.
RECOVERY
PROBABLE
1.
Defective relay AFLR.
CAUSES
2.
Defective wiring.
3.
Defective MLSD16 card in slot 15.
4.
Defective MDIP16 card in slot 12.
FAULT
1.
Switch ON circuit breakers MB1, MB2 and MPCB breakers only and
ISOLATION
all other breakers in OFF position. Check the status of AFLR relay.
The relay should be in energised position.
2.
If the AFL Relay is in de-energized position, check the voltage
between 50 wire at the coil and locomotive 4-wire.
A. If the voltage is zero, check the continuity of the 50-wire loop
connected to the AFL Relay. Identify the wrong connections and
rectify.
3.
If the voltage at 50-wire (AFLR terminal) is more than 65V, check
the voltage between locomotive 50 wire and the wire AFLRCL at the
coil terminal.
A. If the voltage is zero, there is no continuity of AFLRCL wire from
MEP660 to AFLR relay.
a) Check the slackness of the connector at MEP for the cable ID:
AZ. If slack tighten the connector.
b) Check the continuity of the wire AFLRCL from the coil terminal
to the connector of cable ID: AZ
(Pin - L). If necessary
replace the cable.
c) If still the AFL Relay is not energized, the MLSD 16 card in
slot 15 might be defective. Replace and check up.
4.
If the Voltage is more than 65V and the AFL Relay is not energized,
then the relay is defective. Replace the relay.
5.
If the AFL Relay is energized and the still the fault is logging:
6.
Check the status of the Green LED 12 on the digital input card
MDIP16 in slot 12.
7.
If the Green LED 12 is not glowing, check the voltage between wire
51 at the AFLR interlock and locomotive 4 wire.
A. If the voltage is zero check the continuity of 51 wire connected
to AFLR interlock.
8.
If the Voltage is more than 65 V, check the voltage between wire
No. AFLRFB at the relay terminal and locomotive 4 wire.
A. If the voltage is zero, AFLR interlock is bad. Replace the relay. If
the Green LED still does not glow
9.
If the voltage at AFLRFB (relay interlock) is more than 65V,
A. Check the slackness of the connector at the control unit for the
cable ID: AW. Tighten the connector if slack.
B. Check the continuity of the wire AFLRFB from the coil terminal
163
to the connector pin-N. If necessary replace the cable.
C. If the Green LED is not glowing still the digital input card
MDIP16 in slot No. 12 might be defective. Replace the card and
check up.
10. If the Green LED 12 is glowing, and yellow LED is not glowing:
a) LED might be defective.
b) The card might be defective. Replace the card and check up.
Set the display mode to ‘Test Mode’ and select ‘Manual Test for
inputs’ Check the status of the AFLRFB input. The status should be
‘HIGH’.
Note: This Error message will be generated only if Auto Flasher relay is provided and
“Auto Flasher Enabled” Flag is set.
164
PARAMETER
DESCRIPTION
FAULT CODE
1153
FAULT MESSAGE
VCD Applied Penalty Brake. Move Master Controller Handle to IDLE and
press Reset to release Brake.
RESTRICTIONS
Motoring not permitted till the master handle is brought to IDLE and
loco speed is dropped to zero and blinking LED should stop.
ALARM BELL
5 sec.
RESET LEVEL
LOW, Manual
FAULT
Automatic when the loco speed is zero, master handle is brought to
RECOVERY
IDLE, blinking LED stopped and Press VCD reset buttin.
PROBABLE
1. Driver should perform any loco operation or press alerter reset
CAUSES
switch once in 94 sec. to avoid penalty brakes.
FAULT
Bring the master handle to IDLE, wait till loco speed is dropped to zero,
ISOLATION
wait till VCD LED blinking is stopped, and then press VCD reset push
button to release penalty brakes.
PARAMETER
DESCRIPTION
FAULT CODE
1154
FAULT MESSAGE
MCU EEPROM Faulty. All MCU Faults Cleared.
RESTRICTIONS
--
ALARM BELL
5 sec.
RESET LEVEL
High, Manual
FAULT
--
RECOVERY
PROBABLE
System detected fault while writing the faults on EEPROM.
CAUSES
FAULT
--
ISOLATION
165
PARAMETER
DESCRIPTION
FAULT CODE
1155
FAULT MESSAGE
DEB Engine Breaker Off.
RESTRICTIONS
Only indication, there is no restriction.
ALARM BELL
30 seconds.
RESET LEVEL
LOW, Manual
If the fault condition is still present when cleared manually, the fault
will be generated again.
FAULT
Automatic when the DEB breaker is switched ON.
RECOVERY
PROBABLE
1.
DEB (Eng) Breaker is tripped/switched OFF.
CAUSES
2.
Faulty wiring.
3.
Defective digital input card MDIP16 in slot No. 13.
FAULT
1.
Switch ON DEB (Eng) if tripped / Switched OFF.
ISOLATION
2.
Check the status of Green LED 5 on the Digital input card MDIP16
in slot No. 13
3.
If the green LED 5 is not glowing, check the voltage between wire-
50 at the breaker and locomotive 4 wire.
A. If the voltage is zero, check the wire continuity of the 50-wire
loop connected to breaker.
4.
If the voltage at wire-50 is more than 65 V, check the voltage
between wire 73A at the breaker and the locomotive 4-wire.
A. If the voltage is zero even though DEB (eng.) is ON, then the
breaker is defective. Replace the breaker.
5.
If the voltage at 73A (breaker terminal) is more than 65V, check
the voltage between 73A at backside TB and locomotive 4 wire.
A. If the voltage is zero, the wire 73A connected from breaker to
TB is open circuited. Replace the wire.
6.
If the Voltage at 73A (backside TB) is more than 65V,
A. Check the slack ness of the connector at MEP-660 for the cable
ID: AX. If slack tighten the connector.
B. Check the continuity of the wire 73A from TB to the connector
pin- F. If necessary replace the cable.
C. If still Green LED on the digital input card is not glowing, the
digital input card MDIP16 in slot No. 13 might be defective.
Replace the card and check up.
7.
If the green LED is glowing, and corresponding Yellow LED is not
glowing on the card:
A. Either LED or the card might be defective. Replace the card and
check up.
166
PARAMETER
DESCRIPTION
FAULT CODE
1156
FAULT MESSAGE
DEB Car body Breaker Off.
RESTRICTIONS
Only indication, there is no restriction.
ALARM BELL
30 seconds.
RESET LEVEL
LOW, Manual
If the fault condition is still present when cleared manually, the fault
will be generated again.
FAULT
Automatic when the DEB breaker is switched ON
RECOVERY
PROBABLE
1.
DEB (Car) Breaker is tripped/switched OFF.
CAUSES
2.
Faulty wiring.
3.
Defective digital input card MDIP16 in slot No. 13.
FAULT
1.
Switch ON DEB (Car) in tripped / Switched OFF.
ISOLATION
2.
Check the status of Green LED 6 on the Digital input card MDIP16
in slot No. 13
3.
If the green LED 6 is not glowing, check the voltage between wire
No. 50 at the breaker and locomotive 4 wire.
A. If the voltage is zero, check the wire continuity of the 50-wire
loop connected to breaker.
4.
If the voltage at wire-50 (breaker terminal) is more than 65 V,
check the voltage between wire 73B at the breaker and the
locomotive 4 wire.
A. If the voltage is zero even though DEB (Car.) is ON, then the
breaker is defective. Replace the breaker.
5.
If the voltage at 73B (breaker terminal) is more than 65V, check
the voltage between 73B at backside TB and locomotive 4 wire.
A. If the voltage is zero, the wire 73B connected from breaker to
TB is open circuited. Replace the wire.
6.
If the Voltage at 73B at backside TB, is more than 65V,
A. Check the slack ness of the connector at MEP-660 for the cable
ID: AX. If slack tighten the connector.
B. Check the continuity of the wire 73B from TB to the connector
pin- G. If necessary replace the cable.
C. If still Green LED on the digital input card is not glowing, the
digital input card MDIP16 in slot No. 13 might be defective.
Replace the card and check up.
7.
If the green LED is glowing, and corresponding Yellow LED is not
glowing on the card:
A. Either LED or the card might be defective. Replace the card and
check up.
167
PARAMETER
DESCRIPTION
FAULT CODE
1157
FAULT MESSAGE
SLBR ckt Open. Run Auto/Manual Tests
RESTRICTIONS
No Self-load box test
ALARM BELL
5 sec.
RESET LEVEL
LOW, Manual
If the fault condition is still present when cleared manually, the fault
will be generated again.
FAULT
Automatic when SLBR auxiliary contact is closed.
RECOVERY
PROBABLE
This message will log only after selecting self-load test through Display
CAUSES
unit.
1. Defective SLBR relay (bad contact of feedback interlock).
2. Defective wiring.
3. Slackness of Connector of cable (ID: AZ) at MEP-660.
4. Defective digital output card MLSD 16 in slot 15.
5. Slackness of connector of cable (ID: AX) at MEP-660
6. Defective digital input card MDIP 16 in slot 13.
7. Control air pressure is low or zero and none of the SLBC contactors
picked up.
FAULT
Select self-load test option under Test menu option from Display unit.
ISOLATION
1.
Check the status of SLBR relay. If SLBR relay is not picking up,
check the supply at SLBR relay coil terminals.
A. If the voltage is more than 65V, and still the relay is not picking
up then the SLBR relay is defective. Replace the relay.
B. If the voltage is zero, check the voltage between wire 13 at coil
terminal and wire 4 of locomotive.
a. If the voltage is zero, check the continuity of 13-wire loop
coming to SLBR relay. If necessary replace the open
circuited / wrong wiring.
b. If voltage is more than 65V, check the voltage between
SLBRCL wire and wire 50 of locomotive.
i)
If the voltage is zero, check slackness of connector of
cable (Cable ID: AZ) at MEP-660. If the connector is
slack tighten the same.
ii)
Check continuity of wire SLBRCL from SLBR coil
terminal to MEP-660 (Cable ID: AZ Pin-N). If
necessary replace the cable.
iii)
If continuity of wire SLBRCL is OK and still the
voltage is zero, MLSD 16 card in slot 15 might be
defective. Replace the MLSD 16 card.
2.
If SLBR is picked up and none of the SLBC contactors picked up,
Check the supply across any magnet valve of SLBC contactor.
A. If the voltage is more than 65V, check for control air pressure.
If it is less than 5 Kg/cm″ adjust the conttol air pressure to 5
Kg/cm″.
B. Check up voltage across other magnet calve coils of SLBC
contactors.
a. If voltage is zero, check the voltage between wire 13SLB
and wire 4 of locomotive.
b. If voltage is zero, SLBR interlock is bad or supply to 13 is
missing. Identify wrong wiring or replace SLBR relay if
168
necessary.
3. If SLBR is in pickd up condition and any of the SLBC contactor is
not picked up, concerned SLBR interlock is bad or 13SLB wire loop
is missing. Identify and rectify.
4. If the SLBR relay and all SLBC contactors are picking up, then
check the voltage between wire 51 at SLBC interlocks and wire 4 of
locomotive.
A. If voltage is zero, 51-wire loop is defective. Identify and
replace the wrong wiring.
B. If voltage is more than 65 volts, check the following:
a. Check the slackness of connector of cable ID: AX, if slack
tighten the connector.
b. Check the continuity of wire SLBCFB from SLBC aux.
Interlock to pin -P of connector ID: AX. If no continuity,
replace the cable.
c. Check the status of LED-13 on MDIP16 card in slot -12. If
LED is OFF, inspite of continuity is OK and connector is tight
then MDIP16 card in slot-12 might be defective. Replace the
MDIP16 card in slot-12.
169
PARAMETER
DESCRIPTION
FAULT CODE
1158
FAULT MESSAGE
AEB Applied Brake
Move master controller Handle to IDLE
And Press AEB Reset to release Brake
RESTRICTIONS
Motoring not permitted till the master handle is brought to IDLE and
loco speed is dropped below 10 Kmph (set value).
ALARM BELL
5 sec.
RESET LEVEL
LOW, Manual
If the fault condition is still present when cleared manually, the fault
will be generated again.
FAULT
Automatic when the loco speed is dropped below 10 kmph (set value)
RECOVERY
and master handle is brought to IDLE.
PROBABLE
Actually this is not a fault in the locomotive performance. This is a
CAUSES
warning message to driver that penalty brakes are applied due to Loco
speed is increased beyond the set limit and ‘Auto Emergency Brake
system’ feature is enabled.
Whenthis feature is enabled, Driver should control the loco speed
within the set limit other wise system initiates penalty brakes.
FAULT
Bring the master handle to IDLE.
ISOLATION
Wait till loco speed is dropped below 10 kmph (User settable) and
Press AEB reset push button to release penalty brakes.
170
PARAMETER
DESCRIPTION
FAULT CODE
1159
FAULT MESSAGE
Engine Speed Sensor1 faulty.
Running with MCBG communication
RESTRICTIONS
--
ALARM BELL
5 sec.
RESET LEVEL
LOW, Manual
If the fault condition is still present when cleared manually, the fault
will be generated again.
FAULT
Automatic when the engine RPM signal is sensed normally from Engine
RECOVERY
Speed Sensor 1.
PROBABLE
1.
Engine Speed Sensor 1 faulty.
CAUSES
2.
Defective SSI unit.
3.
Defective cables.
4.
Defective RDB / FDB.
5.
Defective MFIP16 card.
FAULT
1.
Shut down the engine and reset the fault manually.
ISOLATION
2.
Check the welding condition of the ESS weld nut on the cam gear
cover. If weld nut is slack or welding crack, remove the cam gear
and attend the welding.
3.
Check for any slackness in the ESS fitment. If so, remove the ESS
and adjust the gap as per the Instruction manual of Doc No: IM 46
4.
Switch OFF MPCB breaker and remove ESS1 cable connector at SSI
unit / RDB (Version 1.0 locos). Check the continuity of wires in the
ESS1 cable and ensure no short between pin-to-pin and pin to
ground.
5.
After ensuring cable continuity and no ground fault, reconnect the
cable at SSI unit / RDB.
6.
Switch ON MPCB breaker and measure voltage between pin B & C
of the ESS cable connector. The voltage should be +12V with pin C
positive.
A. If the voltage is zero / less:
a) SSI unit / RDB is defective. Replace the SSI unit / RDB.
B. If voltage is +12V, reconnect the cable connector to ESS.
Ensure tightness of connectors both at ESS and SSI unit
/ RDB.
7.
Crank the engine, check the engine RPM signal on the Display unit.
A. Raise the notch and ensure notch wise engine RPM is showing
correctly on the Display.
B. If engine RPM on Display is erratic / fluctuating / no RPM.
Replace the ESS1. Adjust the air gap as per the above-referred
Maintenance Insturctions manual.
8.
Repeat point 7 and check the Engine RPM on Display unit.
A. If engine RPM on Display is erratic / fluctuating / no RPM.
MFIP16 card might be defective. Replace the card and repeat
point 7.
171
PARAMETER
DESCRIPTION
FAULT CODE
1160
FAULT MESSAGE
Engine Speed Sensor 2 faulty.
RESTRICTIONS
--
ALARM BELL
5 sec.
RESET LEVEL
LOW, Manual
If the fault condition is still present when cleared manually, the fault
will be generated again.
FAULT
Automatic when the engine RPM signal is sensed normally from Engine
RECOVERY
Speed Sensor 2.
PROBABLE
1.
Engine Speed Sensor 2 faulty.
CAUSES
2.
Defective SSI unit.
3.
Defective cables.
4.
Defective RDB / FDB.
5.
Defective MFIP16 card.
FAULT
1.
Shut down the engine and reset the fault manually.
ISOLATION
2.
Check the welding condition of the ESS2 weld nut on the cam gear
cover. If weld nut is slack or welding crack, remove the cam gear
cover and attend the welding.
3.
Check for any slackness in the ESS2 fitment. If so, remove the
ESS2 and adjust the gap as per the Instruction manual of Doc No:
IM 46.
4.
Switch OFF MPCB breaker and remove ESS2 cable connector at SSI
unit / RDB (Version 1.0 locos). Check the continuity of wires in the
ESS2 cable and ensure no short between pin-to-pin and pin to
ground.
5.
After ensuring cable continuity and no ground fault, reconnect the
cable at SSI unit / RDB.
6.
Switch ON MPCB breaker and measure voltage between pin B & C
of the ESS2 cable connector at ESS2 end. The voltage should be
+12V with pin C positive.
A. If the voltage is zero / less:
a) SSI unit / RDB is defective. Replace the SSI unit / RDB.
B. If voltage is +12V, reconnect the cable connector to ESS2.
Ensure tightness of connectors both at ESS2 and SSI unit
/
RDB.
7.
Crank the engine, check the engine RPM signal on the Display unit.
A. Raise the notch and ensure notch wise engine RPM is showing
correctly on the Display.
B. If engine RPM on Display is erratic / fluctuating / no RPM.
Replace the ESS2. Adjust the air gap as per the above-referred
Maintenance Insturctions manual.
8.
Repeat point 7 and check the Engine RPM on Display unit.
A. If engine RPM on Display is erratic / fluctuating / no RPM.
MFIP16 card might be defective. Replace the card and repeat
point 7.
172
PARAMETER
DESCRIPTION
FAULT CODE
1165
FAULT MESSAGE
BKT Contact Open for Traction Motor 1 in Dynamic Braking
RESTRICTIONS
--
ALARM BELL
5 sec.
RESET LEVEL
LOW, Manual
If the fault condition is still present when cleared manually, the fault
will be generated again.
FAULT
Automatic when current detected through corresponding Traction Motor
RECOVERY
current sensor (TM # AI).
PROBABLE
Any open circuit in the grid circuit of TM1 will log this during Dynamic
CAUSES
Braking.
1. Grid resistor open circuit / connecting cables open circuited.
2. Open circuit of BKT contact in TM1 grid circuit.
3. Open circuit of TM1 armature.
4. Defective current sensor.
5. Defective inter connecting cables.
6. Defective ADB module.
7. Defective MAIP8_WS card.
FAULT
1. Download the fault data pack and ensure there is no ‘Traction Motor
ISOLATION
1 Current Sensor faulty’ message after the above message. If the
message is logged, trouble shoot as per fault code 1189.
2. Check for TM1 circuit open fault message logged after the above
message. If the message is logged trouble shoot as per fault code
1055.
3. If there is no TM1 Current Sensor faulty message:
A. Check the continuity of grid resistor, identify and replace the
open circuited grid resistor.
B. Check for any over heated / burnt cable connections at grid
resistors and BKT contacts. Replace any burnt / over heated grid
cables.
C. Check for any foreign insulating material in between BKT
contacts. Remove foreign material.
D. Manually operate BKT to Braking side and observe the contacts
for proper closing. If any contact is not closing, in Braking side
attend to BKT contacts. If necessary replace BKT.
173
PARAMETER
DESCRIPTION
FAULT CODE
1166
FAULT MESSAGE
BKT Contact Open for Traction Motor 2 in Dynamic Braking
RESTRICTIONS
--
ALARM BELL
5 sec.
RESET LEVEL
LOW, Manual
If the fault condition is still present when cleared manually, the fault
will be generated again.
FAULT
Automatic when current detected through corresponding Traction Motor
RECOVERY
current sensor (TM # AI).
PROBABLE
Any open circuit in the grid circuit of TM2 will log this during Dynamic
CAUSES
Braking.
1. Grid resistor open circuit / connecting cables open circuited.
2. Open circuit of BKT contact in TM2 grid circuit.
3. Open circuit of TM2 armature.
4. Defective current sensor.
5. Defective inter connecting cables.
6. Defective ADB module.
7. Defective MAIP8_WS card.
FAULT
1. Download the fault data pack and ensure there is no ‘Traction Motor
ISOLATION
2 Current Sensor faulty’ message after the above message. If the
message is logged, trouble shoot as per fault code 1190.
2. Check for TM2 circuit open fault message logged after the above
message. If the message is logged trouble shoot as per fault code
1056.
3. If there is no TM2 Current Sensor faulty message:
A. Check the continuity of grid resistor, identify and replace the
open circuited grid resistor.
B. Check for any over heated / burnt cable connections at grid
resistors and BKT contacts. Replace any burnt / over heated grid
cables.
C. Check for any foreign insulating material in between BKT
contacts. Remove foreign material.
D. Manually operate BKT to Braking side and observe the contacts
for proper closing. If any contact is not closing, in Braking side
attend to BKT contacts. If necessary replace BKT.
174
PARAMETER
DESCRIPTION
FAULT CODE
1167
FAULT MESSAGE
BKT Contact Open for Traction Motor 3 in Dynamic Braking
RESTRICTIONS
--
ALARM BELL
5 sec.
RESET LEVEL
LOW, Manual
If the fault condition is still present when cleared manually, the fault
will be generated again.
FAULT
Automatic when current detected through corresponding Traction Motor
RECOVERY
current sensor (TM # AI).
PROBABLE
Any open circuit in the grid circuit of TM3 will log this during Dynamic
CAUSES
Braking.
1. Grid resistor open circuit / connecting cables open circuited.
2. Open circuit of BKT contact in TM3 grid circuit.
3. Open circuit of TM3 armature.
4. Defective current sensor.
5. Defective inter connecting cables.
6. Defective ADB module.
7. Defective MAIP8_WS card.
FAULT
1. Download the fault data pack and ensure there is no ‘Traction Motor
ISOLATION
3 Current Sensor faulty’ message after the above message. If the
message is logged, trouble shoot as per fault code 1191.
2. Check for TM3 circuit open fault message logged after the above
message. If the message is logged trouble shoot as per fault code
1057.
3. If there is no TM3 Current Sensor faulty message:
A. Check the continuity of grid resistor, identify and replace the
open circuited grid resistor.
B. Check for any over heated / burnt cable connections at grid
resistors and BKT contacts. Replace any burnt / over heated grid
cables.
C. Check for any foreign insulating material in between BKT
contacts. Remove foreign material.
D. Manually operate BKT to Braking side and observe the contacts
for proper closing. If any contact is not closing, in Braking side
attend to BKT contacts. If necessary replace BKT.
175
PARAMETER
DESCRIPTION
FAULT CODE
1168
FAULT MESSAGE
BKT Contact Open for Traction Motor 4 in Dynamic Braking
RESTRICTIONS
--
ALARM BELL
5 sec.
RESET LEVEL
LOW, Manual
If the fault condition is still present when cleared manually, the fault
will be generated again.
FAULT
Automatic when current detected through corresponding Traction Motor
RECOVERY
current sensor (TM # AI).
PROBABLE
Any open circuit in the grid circuit of TM4 will log this during Dynamic
CAUSES
Braking.
1. Grid resistor open circuit / connecting cables open circuited.
2. Open circuit of BKT contact in TM4 grid circuit.
3. Open circuit of TM4 armature.
4. Defective current sensor.
5. Defective inter connecting cables.
6. Defective ADB module.
7. Defective MAIP8_WS card.
FAULT
1. Download the fault data pack and ensure there is no ‘Traction Motor
ISOLATION
4 Current Sensor faulty’ message after the above message. If the
message is logged, trouble shoot as per fault code 1192.
2. Check for TM4 circuit open fault message logged after the above
message. If the message is logged trouble shoot as per fault code
1058.
3. If there is no TM4 Current Sensor faulty message:
A. Check the continuity of grid resistor, identify and replace the
open circuited grid resistor.
B. Check for any over heated / burnt cable connections at grid
resistors and BKT contacts. Replace any burnt / over heated grid
cables.
C. Check for any foreign insulating material in between BKT
contacts. Remove foreign material.
D. Manually operate BKT to Braking side and observe the contacts
for proper closing. If any contact is not closing, in Braking side
attend to BKT contacts. If necessary replace BKT.
176
PARAMETER
DESCRIPTION
FAULT CODE
1169
FAULT MESSAGE
BKT Contact Open for Traction Motor 5 in Dynamic Braking
RESTRICTIONS
--
ALARM BELL
5 sec.
RESET LEVEL
LOW, Manual
If the fault condition is still present when cleared manually, the fault
will be generated again.
FAULT
Automatic when current detected through corresponding Traction Motor
RECOVERY
current sensor (TM # AI).
PROBABLE
Any open circuit in the grid circuit of TM5 will log this during Dynamic
CAUSES
Braking.
1. Grid resistor open circuit / connecting cables open circuited.
2. Open circuit of BKT contact in TM5 grid circuit.
3. Open circuit of TM5 armature.
4. Defective current sensor.
5. Defective inter connecting cables.
6. Defective ADB module.
7. Defective MAIP8_WS card.
FAULT
1. Download the fault data pack and ensure there is no ‘Traction Motor
ISOLATION
5 Current Sensor faulty’ message after the above message. If the
message is logged, trouble shoot as per fault code 1193.
2. Check for TM5 circuit open fault message logged after the above
message. If the message is logged trouble shoot as per fault code
1059.
3. If there is no TM5 Current Sensor faulty message:
A. Check the continuity of grid resistor, identify and replace the
open circuited grid resistor.
B. Check for any over heated / burnt cable connections at grid
resistors and BKT contacts. Replace any burnt / over heated grid
cables.
C. Check for any foreign insulating material in between BKT
contacts. Remove foreign material.
D. Manually operate BKT to Braking side and observe the contacts
for proper closing. If any contact is not closing, in Braking side
attend to BKT contacts. If necessary replace BKT.
177
PARAMETER
DESCRIPTION
FAULT CODE
1170
FAULT MESSAGE
BKT Contact Open for Traction Motor 6 in Dynamic Braking
RESTRICTIONS
--
ALARM BELL
5 sec.
RESET LEVEL
LOW, Manual
If the fault condition is still present when cleared manually, the fault
will be generated again.
FAULT
Automatic when current detected through corresponding Traction Motor
RECOVERY
current sensor (TM # AI).
PROBABLE
Any open circuit in the grid circuit of TM6 will log this during Dynamic
CAUSES
Braking.
1. Grid resistor open circuit / connecting cables open circuited.
2. Open circuit of BKT contact in TM6 grid circuit.
3. Open circuit of TM6 armature.
4. Defective current sensor.
5. Defective inter connecting cables.
6. Defective ADB module.
7. Defective MAIP8_WS card.
FAULT
1. Download the fault data pack and ensure there is no ‘Traction Motor
ISOLATION
6 Current Sensor faulty’ message after the above message. If the
message is logged, trouble shoot as per fault code 1194.
2. Check for TM6 circuit open fault message logged after the above
message. If the message is logged trouble shoot as per fault code
1060.
3. If there is no TM6 Current Sensor faulty message:
A. Check the continuity of grid resistor, identify and replace the
open circuited grid resistor.
B. Check for any over heated / burnt cable connections at grid
resistors and BKT contacts. Replace any burnt / over heated grid
cables.
C. Check for any foreign insulating material in between BKT
contacts. Remove foreign material.
D. Manually operate BKT to Braking side and observe the contacts
for proper closing. If any contact is not closing, in Braking side
attend to BKT contacts. If necessary replace BKT.
178
4.0. LOW PRIORITY FAULTS
PARAMETER
DESCRIPTION
FAULT CODE
1173
FAULT MESSAGE
Alternator Voltage Sensor Faulty
RESTRICTIONS
Warning only
ALARM BELL
--
RESET LEVEL
MEDIUM, Manual
If the fault condition is still present when cleared manually, the fault
will be generated again.
FAULT
Automatic when the Alternator voltage Sensor is detected normal.
RECOVERY
PROBABLE
1.
Defective voltage sensor TAV.
CAUSES
2.
Defective cables.
3.
Defective ADB3
4.
Defective MAIP8_EP card in slot No. 7.
FAULT
1.
Remove the cable connector at the sensor.
ISOLATION
2.
Measure voltage between pin B and pin A. The voltage should be
24V with pin A positive.
3.
Measure voltage between pin B and pin C. The voltage should be
24V with pin B positive.
4.
If any of the above voltages is zero or less:
A. Remove sensor cable connector on ADB3 with cable ID: T.
B. Measure voltages between pins A, B and C.
a) If voltage between B & A is less than 24V or voltage between
B & C is less than 24V, ADB3 is defective. Replace the ADB.
b) If the voltages are +24V between pins B & A and -24V
between pins B & C, The interconnecting cable between ADB
and sensor with cable ID: T is defective.
5.
If +24V and -24V supply is available at the connector,
A. Sensor may be defective. Replace and check.
B. The 19 pin connectors at ADB and MEP-660 control unit with
cable ID: AA might be slack. Check and tighten the connectors.
C. The cable with ID: AA may be defective. Replace the cable and
check up.
D. MAIP8_EP card might be defective. Replace the card and check
up.
179
PARAMETER
DESCRIPTION
FAULT CODE
1174
FAULT MESSAGE
EP Analogue DB Power Supply FAULTY
RESTRICTIONS
Warning only
ALARM BELL
--
RESET LEVEL
MEDIUM, Manual
If the fault condition is still present when cleared manually, the fault
will be generated again.
FAULT
Automatic when the EP analogue DB power supply is detected to
RECOVERY
normal.
PROBABLE
Most probably this fault accompany with ‘xxxxx sensor faulty’ for the
CAUSES
sensors connected to the ADB3 faulty.
1. Defective Analog distribution box.
2. Defective wiring.
FAULT
1. Replace the ADB and check up
ISOLATION
2. Replace the cable ID: AB and check up.
3. Check for disconnected wires at back side TB for the wire No. PSH3.
4. Check the continuity of wire PSH3 from TB to the Cable connector
(Cable ID: AW Pin - C). If necessary replace the cable.
5. Check the status of the Green LED 4 on the digital input card
MDIP16 in slot No. 12.
6. If the green LED glowing and corresponding Yellow LED 4 is not
glowing the digital input card MDIP16 is defective. Replace and
check up.
180
PARAMETER
DESCRIPTION
FAULT CODE
1175
FAULT MESSAGE
Alternator Field Current Sensor Faulty
RESTRICTIONS
Warning only
ALARM BELL
--
RESET LEVEL
MEDIUM, Manual
If the fault condition is still present when cleared manually, the fault
will be generated again.
FAULT
Automatic when the MEP-660 detects the alternator field current
RECOVERY
sensor EXAI working normal.
PROBABLE
1. EXAI current sensor faulty.
CAUSES
2. Defective cables
3. Defective ADB3
4. Defective MAIP8_EP card in slot 7.
FAULT
1. Remove the cable connector at the sensor.
ISOLATION
2. Measure voltage between pin B & A of the cable connector. The
voltage should be 24V with pin A positive. (+24V)
3. Measure voltage between pin B & C of the cable connector. The
voltage should be 24V with pin B positive. (-24V)
4. If any of the above voltages (+24V) or (-24V) is zero / less:
A. Remove sensor cable connector on ADB3 with cable ID: U.
B. Measure voltages between pins A, B and C of the ADB
connector.
a) If voltage between B & A is less than 24V or voltage between
B & C is less than 24V, ADB3 is defective. Replace the ADB.
b) If the voltages between pins B&A is +24V and voltage
between pins B & C is -24V, the interconnecting cable
between ADB and sensor with cable ID: U is defective.
5. If +24V and -24V supply is available at the sensor cable connector,
A. Sensor may be defective. Replace and check.
B. The 19 pin connectors at ADB and MEP-660 control unit with
cable ID: AA may be slack. Check and tighten the connectors.
C. The cable with ID: AA may be defective. Replace the cable and
check up.
D. MAIP8_EP card might be defective. Replace the card and check
up.
181
PARAMETER
DESCRIPTION
FAULT CODE
1176
FAULT MESSAGE
Exciter Field Current Sensor Faulty
RESTRICTIONS
Warning only
ALARM BELL
--
RESET LEVEL
MEDIUM, Manual
If the fault condition is still present when cleared manually, the fault
will be generated again.
FAULT
Automatic when the MEP-660 detects the Exciter field current sensor
RECOVERY
EXFI working normal.
PROBABLE
1.
EXFI current sensor faulty.
CAUSES
2.
Defective cables
3.
Defective ADB3
4.
Defective MAIP8_EP card in slot 7.
FAULT
1.
Remove the cable connector at the sensor.
ISOLATION
2.
Measure voltage between pin B & A of the cable connector. The
voltage should be 24V with pin a positive. (+24V)
3.
Measure voltage between pin B & C of the cable connector. The
voltage should be 24V with pin B positive. (-24V)
4.
If any of the above voltages (+24V) or (-24V) is zero / less:
A. Remove sensor cable connector on ADB3 with cable ID: V.
B. Measure voltages between pins A, B and C of the ADB
connector.
a) If voltage between B & A is less than 24V or voltage between
B & C is less than 24V, ADB3 is defective. Replace the ADB.
b) If the voltages between pins B&A is +24V and voltage
between pins B & C is -24V, the interconnecting cable
between ADB and sensor with cable ID: V is defective.
5.
If +24V and -24V supply is available at the sensor cable connector,
A. Sensor may be defective. Replace and check.
B. The 19 pin connectors at ADB and MEP-660 control unit with
cable ID: AA may be slack. Check and tighten the connectors.
C. The cable with ID: AA may be defective. Replace the cable and
check up.
D. MAIP8_EP card might be defective. Replace the card and check
up.
182
PARAMETER
DESCRIPTION
FAULT CODE
1177
FAULT MESSAGE
Engine Tacho Output Noisy
RESTRICTIONS
Warning only
ALARM BELL
--
RESET LEVEL
High, Manual
If the fault condition is still present when cleared manually, the fault
will be generated again.
FAULT
Manual only
RECOVERY
PROBABLE
1. Noisy output from tacho generator continuously.
CAUSES
FAULT
1. Reset the fault manually.
ISOLATION
2. Check up the tacho generator for any loose connections or loose
magnets on the rotor etc. Replace the tacho generator if necessary.
PARAMETER
DESCRIPTION
FAULT CODE
1178
FAULT MESSAGE
Engine Tacho Output Noisy
RESTRICTIONS
Warning only
ALARM BELL
--
RESET LEVEL
High, Manual
If the fault condition is still present when cleared manually, the fault
will be generated again.
FAULT
Manual only
RECOVERY
PROBABLE
1. Noisy output from tacho generator.
CAUSES
FAULT
1. Reset the fault manually.
ISOLATION
2. Check up the tacho generator for any loose connections or loose
magnets on the rotor etc. Replace the tacho generator if necessary.
183
PARAMETER
DESCRIPTION
FAULT CODE
1179
FAULT MESSAGE
MCU EEPROM Faulty. Default CFG record loaded
RESTRICTIONS
Warning only
ALARM BELL
--
RESET LEVEL
High, Manual
FAULT
--
RECOVERY
PROBABLE
This fault will be logged while switching on the supply. Loco will work
CAUSES
with default parameters.
FAULT
--
ISOLATION
PARAMETER
DESCRIPTION
FAULT CODE
1180
FAULT MESSAGE
MCU EEPROM Write Error at Power Off. Last MCU Fault Cleared.
RESTRICTIONS
Warning only
ALARM BELL
--
RESET LEVEL
High, Manual
FAULT
--
RECOVERY
PROBABLE
System is switched off while writing the fault message on the EEPROM.
CAUSES
FAULT
--
ISOLATION
184
PARAMETER
DESCRIPTION
FAULT CODE
1181
FAULT MESSAGE
WS EEPROM Faulty. Default CFG record loaded
RESTRICTIONS
Warning only
ALARM BELL
--
RESET LEVEL
High, Manual
FAULT
--
RECOVERY
PROBABLE
This fault will be logged while switching ON power supply. Loco can
CAUSES
work with default parameters.
FAULT
--
ISOLATION
PARAMETER
DESCRIPTION
FAULT CODE
1182
FAULT MESSAGE
WS Analogue DB Power Supply FAULTY
RESTRICTIONS
Warning only
ALARM BELL
--
RESET LEVEL
MEDIUM, Manual
If the fault condition is still present when cleared manually, the fault
will be generated again.
FAULT
Automatic when the WS analogue DB power supply is detected to
RECOVERY
normal.
PROBABLE
Most probably this fault accompany with associated sensors
CAUSES
(Connected to the ADB2) faulty.
1. Defective Analog distribution box.
2. Defective wiring.
FAULT
1. Replace the ADB and check up
ISOLATION
2. Replace the cable ID:I and check up.
3. Check for disconnected wires at backside TB for the wire No. PSH2.
4. Check the continuity of wire PSH2 from TB to the Cable connector
(Cable ID:I Pin - C). If necessary replace the cable.
5. Check the status of the Green LED 5 on the digital input card
MDIP16 in slot No. 12.
6. If the green LED glowing and corresponding Yellow LED 5 is not
glowing the digital input card MDIP16 is defective. Replace and
check up.
185
PARAMETER
DESCRIPTION
FAULT CODE
1183
FAULT MESSAGE
Traction Alternator Current Sensor Faulty.
RESTRICTIONS
Dynamic brake prohibited
ALARM BELL
--
RESET LEVEL
MEDIUM, Manual
If the fault condition is still present when cleared manually, the fault
will be generated again.
FAULT
Automatic when the Tr. Alternator current sensor TAAI is detected as
RECOVERY
working normal.
PROBABLE
1.
TAAI current sensor faulty.
CAUSES
2.
Defective cables
3.
Defective ADB3
4.
Defective MAIP8_EP card in slot 7.
FAULT
1.
Set the locomotive to motoring mode with brakes applied and notch
ISOLATION
1. Record the Tr. Alternator current TA Amps on the display. Bring
the Throttle to notch IDLE.
2.
Set the display mode to ‘Wheel Slip’ under ‘Display’ menu available
in the main menu. Bring the notch to 1. Record all the 6 traction
motor currents.
3.
If sum of all the T.M currents is more or less equal to Tr. Alternator
current, the fault could be a transient.
4.
If Tr.Alternator current is zero or excess to the sum of Tr.Motor
currents then:
5.
Remove the cable connector at the sensor.
6.
Measure voltage between pin B & A of the cable connector. The
voltage should be 24V with pin A positive. (+24V)
7.
Measure voltage between pin B & C of the cable connector. The
voltage should be 24V with pin B positive. (-24V)
8.
If any of the above voltages (+24V) or (-24V) is zero / less:
A. Remove sensor cable connector on ADB3 with cable ID: S.
B. Measure voltages between pins A, B and C of the ADB
connector.
a) If voltage between B & A is less than 24V or voltage between
B & C is less than 24V, ADB3 is defective. Replace the ADB.
b) If the voltages between pins B&A is +24V and voltage
between pins B & C is -24V, the interconnecting cable
between ADB and sensor with cable ID: S is defective.
9.
If +24V and -24V supply is available at the sensor cable connector,
A. Sensor may be defective. Replace and check.
B. The 19 pin connectors at ADB and MEP-660 control unit with
cable ID: AA may be slack. Check and tighten the connectors.
C. The cable with ID: AA may be defective. Replace the cable and
check up.
D. MAIP8_EP card might be defective. Replace the card and check
up.
186
PARAMETER
DESCRIPTION
FAULT CODE
1184
FAULT MESSAGE
Frequency DB Power Supply FAULTY
RESTRICTIONS
Warning only
ALARM BELL
--
RESET LEVEL
MEDIUM, Manual
If the fault condition is still present when cleared manually, the fault
will be generated again.
FAULT
Automatic when the Frequency analogue DB (RDB) power supply is
RECOVERY
detected to normal.
PROBABLE
Most probably this fault accompany with associated sensors
CAUSES
(Connected to the RDB) faulty.
1. Defective Analog distribution box.
2. Defective wiring.
FAULT
1. Replace the RDB and check up
ISOLATION
2. Replace the cable ID: Q and check up.
3. Check for disconnected wires at back side TB for the wire No. PSH4.
4. Check the continuity of wire PSH4 from TB to the Cable connector
(Cable ID: AW Pin - C). If necessary replace the cable.
5. Check the status of the Green LED 7 on the digital input card
MDIP16 in slot No. 12.
6. If the Green LED glowing and corresponding Yellow LED 7 is not
glowing the digital input card MDIP16 is defective. Replace and
check up.
PARAMETER
DESCRIPTION
FAULT CODE
1185
FAULT MESSAGE
WS EEPROM Faulty. All WS Faults Cleared.
RESTRICTIONS
--
ALARM BELL
5 sec.
RESET LEVEL
High, Manual
FAULT
--
RECOVERY
PROBABLE
System detected fault while writing the faults on EEPROM.
CAUSES
FAULT
--
ISOLATION
187
PARAMETER
DESCRIPTION
FAULT CODE
1186
FAULT MESSAGE
WS EEPROM Write Error at Power Off. Last WS Fault Cleared.
RESTRICTIONS
Warning only
ALARM BELL
--
RESET LEVEL
High, Manual
FAULT
--
RECOVERY
PROBABLE
System is switched off while writing the fault message on the EEPROM.
CAUSES
FAULT
--
ISOLATION
188
PARAMETER
DESCRIPTION
FAULT CODE
1189
FAULT MESSAGE
Traction motor 1 current sensor faulty
RESTRICTIONS
Dynamic braking
ALARM BELL
--
RESET LEVEL
Medium, Manual
If the fault condition is still present when cleared manually, the fault
will be generated again.
FAULT
Automatic when the Tr.Motor current sensor detected working normal.
RECOVERY
PROBABLE
1.
T.M. current sensor TM1AI sensor faulty.
CAUSES
2.
Defective cables
3.
Defective ADB2
1.
Defective MAIP8_WS card in slot 6.
FAULT
1.
Remove the cable connector at the sensor.
ISOLATION
2.
Measure voltage between pin B & A of the cable connector. The
voltage should be 24V with pin A positive. (+24V)
3.
Measure voltage between pin B & C of the cable connector. The
voltage should be 24V with pin B positive. (-24V)
4.
If any of the above voltages (+24V) or (-24V) is zero / less:
A. Remove sensor cable connector on ADB2 with cable ID: A.
B. Measure voltages between pins A, B and C of the ADB2
connector.
a) If voltage between B & A is less than +24V or voltage
between B & C is less than -24V, ADB2 is defective. Replace
the ADB2.
b) If the voltages between pins B&A is +24V and voltage
between pins B & C is -24V, the interconnecting cable
between ADB and sensor with cable ID: A is defective.
5.
If +24V and -24V supply is available at the sensor cable connector,
A. Sensor may be defective. Replace and check.
B. The 19 pin connectors between ADB2 and MEP-660 control unit
with cable ID: G may be slack. Check and tighten the
connectors.
C. The cable with ID: G may be defective. Replace the cable and
check up.
D. MAIP8_WS card might be defective. Replace the card and check
up.
189
PARAMETER
DESCRIPTION
FAULT CODE
1190
FAULT MESSAGE
Traction motor 2 current sensor faulty
RESTRICTIONS
Dynamic braking
ALARM BELL
--
RESET LEVEL
Medium, Manual
If the fault condition is still present when cleared manually, the fault
will be generated again.
FAULT
Automatic when the Tr.Motor current sensor detected working normal.
RECOVERY
PROBABLE
1.
T.M. current sensor TM2AI sensor faulty.
CAUSES
2.
Defective cables
3.
Defective ADB2
2.
Defective MAIP8_WS card in slot 6.
FAULT
1.
Remove the cable connector at the sensor.
ISOLATION
2.
Measure voltage between pin B & A of the cable connector. The
voltage should be 24V with pin A positive. (+24V)
3.
Measure voltage between pin B & C of the cable connector. The
voltage should be 24V with pin B positive. (-24V)
4.
If any of the above voltages (+24V) or (-24V) is zero / less:
A. Remove sensor cable connector on ADB2 with cable ID: B.
B. Measure voltages between pins A, B and C of the ADB2
connector.
a) If voltage between B & A is less than +24V or voltage
between B & C is less than -24V, ADB2 is defective. Replace
the ADB2.
b) If the voltages between pins B&A is +24V and voltage
between pins B & C is -24V, the interconnecting cable
between ADB and sensor with cable ID: B is defective.
5.
If +24V and -24V supply is available at the sensor cable connector,
A. Sensor may be defective. Replace and check.
B. The 19 pin connectors between ADB2 and MEP-660 control unit
with cable ID: G may be slack. Check and tighten the
connectors.
C. The cable with ID: G may be defective. Replace the cable and
check up.
D. MAIP8_WS card might be defective. Replace the card and check
up.
190
PARAMETER
DESCRIPTION
FAULT CODE
1191
FAULT MESSAGE
Traction motor 3 current sensor faulty
RESTRICTIONS
Dynamic braking
ALARM BELL
--
RESET LEVEL
Medium, Manual
If the fault condition is still present when cleared manually, the fault
will be generated again.
FAULT
Automatic when the Tr.Motor current sensor detected working normal.
RECOVERY
PROBABLE
1.
T.M. current sensor TM3AI sensor faulty.
CAUSES
2.
Defective cables
3.
Defective ADB2
3.
Defective MAIP8_WS card in slot 6.
FAULT
1.
Remove the cable connector at the sensor.
ISOLATION
2.
Measure voltage between pin B & A of the cable connector. The
voltage should be 24V with pin A positive. (+24V)
3.
Measure voltage between pin B & C of the cable connector. The
voltage should be 24V with pin B positive. (-24V)
4.
If any of the above voltages (+24V) or (-24V) is zero / less:
A. Remove sensor cable connector on ADB2 with cable ID: C.
B. Measure voltages between pins A, B and C of the ADB2
connector.
a) If voltage between B & A is less than +24V or voltage
between B & C is less than -24V, ADB2 is defective. Replace
the ADB2.
b) If the voltages between pins B&A is +24V and voltage
between pins B & C is -24V, the interconnecting cable
between ADB and sensor with cable ID: C is defective.
5.
If +24V and -24V supply is available at the sensor cable connector,
A. Sensor may be defective. Replace and check.
B. The 19 pin connectors between ADB2 and MEP-660 control unit
with cable ID: G may be slack. Check and tighten the
connectors.
C. The cable with ID: G may be defective. Replace the cable and
check up.
D. MAIP8_WS card might be defective. Replace the card and check
up.
191
PARAMETER
DESCRIPTION
FAULT CODE
1192
FAULT MESSAGE
Traction motor 4 current sensor faulty
RESTRICTIONS
Dynamic braking
ALARM BELL
--
RESET LEVEL
Medium, Manual
If the fault condition is still present when cleared manually, the fault
will be generated again.
FAULT
Automatic when the Tr.Motor current sensor detected working normal.
RECOVERY
PROBABLE
1.
T.M. current sensor TM4AI sensor faulty.
CAUSES
2.
Defective cables
3.
Defective ADB2
4.
Defective MAIP8_WS card in slot 6.
FAULT
1.
Remove the cable connector at the sensor.
ISOLATION
2.
Measure voltage between pin B & A of the cable connector. The
voltage should be 24V with pin A positive. (+24V)
3.
Measure voltage between pin B & C of the cable connector. The
voltage should be 24V with pin B positive. (-24V)
4.
If any of the above voltages (+24V) or (-24V) is zero / less:
A. Remove sensor cable connector on ADB2 with cable ID: D.
B. Measure voltages between pins A, B and C of the ADB2
connector.
a) If voltage between B & A is less than +24V or voltage
between B & C is less than -24V, ADB2 is defective. Replace
the ADB2.
b) If the voltages between pins B&A is +24V and voltage
between pins B & C is -24V, the interconnecting cable
between ADB and sensor with cable ID: D is defective.
5.
If +24V and -24V supply is available at the sensor cable connector,
A. Sensor may be defective. Replace and check.
B. The 19 pin connectors between ADB2 and MEP-660 control unit
with cable ID: G may be slack. Check and tighten the
connectors.
C. The cable with ID: G may be defective. Replace the cable and
check up.
D. MAIP8_WS card might be defective. Replace the card and check
up.
192
PARAMETER
DESCRIPTION
FAULT CODE
1193
FAULT MESSAGE
Traction motor 5 current sensor faulty
RESTRICTIONS
Dynamic braking
ALARM BELL
--
RESET LEVEL
Medium, Manual
If the fault condition is still present when cleared manually, the fault
will be generated again.
FAULT
Automatic when the Tr.Motor current sensor detected working normal.
RECOVERY
PROBABLE
1.
T.M. current sensor TM5AI sensor faulty.
CAUSES
2.
Defective cables
3.
Defective ADB2
5.
Defective MAIP8_WS card in slot 6.
FAULT
1.
Remove the cable connector at the sensor.
ISOLATION
2.
Measure voltage between pin B & A of the cable connector. The
voltage should be 24V with pin A positive. (+24V)
3.
Measure voltage between pin B & C of the cable connector. The
voltage should be 24V with pin B positive. (-24V)
4.
If any of the above voltages (+24V) or (-24V) is zero / less:
A. Remove sensor cable connector on ADB2 with cable ID: E.
B. Measure voltages between pins A, B and C of the ADB2
connector.
a) If voltage between B & A is less than +24V or voltage
between B & C is less than -24V, ADB2 is defective. Replace
the ADB2.
b) If the voltages between pins B&A is +24V and voltage
between pins B & C is -24V, the interconnecting cable
between ADB and sensor with cable ID: E is defective.
5.
If +24V and -24V supply is available at the sensor cable connector,
A. Sensor may be defective. Replace and check.
B. The 19 pin connectors between ADB2 and MEP-660 control unit
with cable ID: G may be slack. Check and tighten the
connectors.
C. The cable with ID: G may be defective. Replace the cable and
check up.
D. MAIP8_WS card might be defective. Replace the card and check
up.
193
PARAMETER
DESCRIPTION
FAULT CODE
1194
FAULT MESSAGE
Traction motor 6 current sensor faulty
RESTRICTIONS
Dynamic braking
ALARM BELL
--
RESET LEVEL
Medium, Manual
If the fault condition is still present when cleared manually, the fault
will be generated again.
FAULT
Automatic when the Tr.Motor current sensor detected working normal.
RECOVERY
PROBABLE
1.
T.M. current sensor TM6AI sensor faulty.
CAUSES
2.
Defective cables
3.
Defective ADB2
6.
Defective MAIP8_WS card in slot 6.
FAULT
1.
Remove the cable connector at the sensor.
ISOLATION
2.
Measure voltage between pin B & A of the cable connector. The
voltage should be 24V with pin A positive. (+24V)
3.
Measure voltage between pin B & C of the cable connector. The
voltage should be 24V with pin B positive. (-24V)
4.
If any of the above voltages (+24V) or (-24V) is zero / less:
A. Remove sensor cable connector on ADB2 with cable ID: F.
B. Measure voltages between pins A, B and C of the ADB2
connector.
a) If voltage between B & A is less than +24V or voltage
between B & C is less than -24V, ADB2 is defective. Replace
the ADB2.
b) If the voltages between pins B&A is +24V and voltage
between pins B & C is -24V, the interconnecting cable
between ADB and sensor with cable ID: F is defective.
5.
If +24V and -24V supply is available at the sensor cable connector,
A. Sensor may be defective. Replace and check.
B. The 19 pin connectors between ADB2 and MEP-660 control unit
with cable ID: G may be slack. Check and tighten the
connectors.
C. The cable with ID: G may be defective. Replace the cable and
check up.
D. MAIP8_WS card might be defective. Replace the card and check
up.
194
PARAMETER
DESCRIPTION
FAULT CODE
1195
FAULT MESSAGE
S1 Auxiliary Contact Stuck Open. Run Auto/Manual Test
RESTRICTIONS
Dynamic braking
ALARM BELL
--
RESET LEVEL
Low, Manual
If the fault condition is still present when cleared manually, the fault
will be generated again.
FAULT
Automatic when the S1 power contactor Aux. Contact closes.
RECOVERY
PROBABLE
1.
Defective Power contactor
CAUSES
2.
Defective wiring.
3.
Defective digital output card MLSD16 in slot No. 14.
4.
Defective digital input card MDIP16 in slot No. 10
FAULT
1.
Set the display mode to ‘Manual Test for outputs’ under ‘Test Mode’
ISOLATION
available in main menu. The display exhibits certain conditions to
be full filled. After that press Enter key to start testing of outputs.
Ensure control air pressure is 5 Kg./Sq.Cm.
2.
Enter 6 against channel no. and then press Enter key to test S1
power contactor. Press 1 to energise the contactor and 0 to de-
energise the contactor.
3.
Press 1 to energise the S1 power contactor.
4.
If the contactor is not picking up. Check the voltage across the
operating coil of the magnet valve.
5.
If the voltage is zero, check the voltage between Wire 13 at the coil
terminal and locomotive 4 wire.
A. If the voltage is zero, check the continuity of 13 wire connected
to the coil terminal.
B. If the voltage is more than 65V, check the voltage between
locomotive 13 wire and S1CL wire at the coil terminal.
C. If the voltage is zero, negative path is not getting completed
through MEP.
a) Check the slackness of the connector at MEP-660 control unit
for the cable ID: AY. If found slack tighten the connector.
b) Check the continuity of wire S1CL from the coil terminal to
the connector of cable ID: AY (pin - G). If necessary replace
the cable.
c) If still voltage is zero, the digital output card MLSD16 in slot
No. 14 might be defective. Replace the card and check once
again.
6.
If the Voltage is more than 65V and still power contactor is not
picking up, then the power contactor or magnet valve or pneumatic
circuit is defective. Identify and replace the component/contactor.
7.
Press 0 to de-energise the power contactor.
8.
While you are toggling the power contactor, check the status of the
Green LED 9 and Yellow LED 9 on the digital input card MDIP16 in
slot 10.
9.
With power contactor energized, Both the LEDs should glow.
10. If the Green LED is not glowing, check the voltage between wire 51
at the power contactor aux. Interlock and locomotive 4 wire.
A. If the voltage is zero, check the continuity of the wire Loop 51
connected to S1 power contactor interlock. Identify faulty wiring
195
and rectify.
B. If the voltage is more than 65V, check the voltage between
S1FB and locomotive 4 wire.
a) If the voltage is zero, the interlock is bad. Replace the
interlock/aux. Contact.
b) If the voltage is more than 65V,
1) Check the slackness of the connector at the MEP660
control unit for the cable ID: AU. If the connector is slack
tighten the connector.
2) Check the continuity of the wire S1FB from the contactor
to the cable (ID: AU) connector pin-K. If necessary
replace the cable.
3) If still Green LED 9 is not glowing, the digital input card
MDIP16 in slot No. 10 defective. Replace the card and
check.
11. If the Green LED 9 is glowing and corresponding yellow LED is not
glowing also, the MDIP16 card is defective.
196
PARAMETER
DESCRIPTION
FAULT CODE
1196
FAULT MESSAGE
S21 Auxiliary Contact Stuck Open. Run Auto/Manual Test
RESTRICTIONS
--
ALARM BELL
--
RESET LEVEL
Low, Manual
If the fault condition is still present when cleared manually, the fault
will be generated again.
FAULT
Automatic when the S21 power contactor Aux. Contact closes.
RECOVERY
PROBABLE
1.
Defective Power contactor
CAUSES
2.
Defective wiring.
3.
Defective digital output card MLSD16 in slot No. 14.
4.
Defective digital input card MDIP16 in slot No. 10
FAULT
1.
Set the display mode to ‘Manual Test for outputs’ under ‘Test Mode’
ISOLATION
available in main menu. The display exhibits certain conditions to
be full filled. After that press Enter key to start testing of outputs.
Ensure control air pressure is 5 Kg./Sq.Cm.
2.
Enter 7 against channel no. and then press Enter key to test S21
power contactor. Press 1 to energise the contactor and 0 to de-
energise the contactor.
3.
Press 1 to energise the S21 power contactor.
4.
If the contactor is not picking up. Check the voltage across the
operating coil of the magnet valve.
5.
If the voltage is zero, check the voltage between Wire 13 at the coil
terminal and locomotive 4 wire.
A. If the voltage is zero, check the continuity of 13 wire connected
to the coil terminal.
B. If the voltage is more than 65V, check the voltage between
locomotive 13 wire and S21CL wire at the coil terminal.
C. If the voltage is zero, negative path is not getting completed
through MEP.
a) Check the slackness of the connector at MEP-660 control unit
for the cable ID: AY. If found slack tighten the connector.
b) Check the continuity of wire S21CL from the coil terminal to
the connector of cable ID: AY (pin - H). If necessary replace
the cable.
c) If still voltage is zero, the digital output card MLSD16 in slot
No. 14 might be defective. Replace the card and check once
again.
6.
If the Voltage is more than 65V and still power contactor is not
picking up, then the power contactor or magnet valve or pneumatic
circuit is defective. Identify and replace the component/contactor.
7.
Press 0 to de-energise the power contactor.
8.
While you are toggling the power contactor, check the status of the
Green LED 10 and Yellow LED 10 on the digital input card MDIP16
in slot 10.
9.
With power contactor energized, Both the LEDs should glow.
10. If the Green LED is not glowing, check the voltage between wire 51
at the power contactor aux. Interlock and locomotive 4 wire.
A. If the voltage is zero, check the continuity of the wire Loop 51
connected to S21 power contactor interlock. Identify faulty
197
|
||
|
|
|