TEST ACTION APPLICABILITY 3 With the DRBIII t in Inputs/Outputs, read the PAWL state. Open the liftgate to full open position. t. Unlatch the latch by pressing the handle switch or using the key and observe the t for a state change. Repeat this step several times while moving the liftgate in different positions and t show the switch state changes correctly every time? All Yes → Replace the Power Liftgate Module. Perform BODY VERIFICATION TEST - VER 1. No → Go To 4 4 Disconnect the Power Liftgate C2 connector. All Yes → Go To 5 No → Repair the Ground wire for an open. Perform BODY VERIFICATION TEST - VER 1. 5 Disconnect the Liftgate Control Module C2 connector. All Yes → Go To 6 No → Repair the Liftgate Pawl Switch Sense wire for an open. Perform BODY VERIFICATION TEST - VER 1. 6 If there are no possible causes remaining, view repair. All Repair Replace the Liftgate Pawl Switch (latch assembly). 811 POWER DOORS - LIFTGATE INCOMPLETE LATCH RELEASE- PAWL SWITCH FAILURE — Continued |