Symptom: RKE PROGRAM LINE OUTPUT SHORT When Monitored and Set Condition: RKE PROGRAM LINE OUTPUT SHORT When Monitored: With ignition in the RUN position. Set Condition: When the BCM senses an over current on the RKE Module Program Enable circuit and the RKE is in PROGRAM or DIAGNOSTIC mode. POSSIBLE CAUSES DTC PRESENT REMOTE KEYLESS ENTRY MODULE - RKE MODULE PROGRAM ENABLE CIRCUIT SHORT TO RKE MODULE PROGRAM ENABLE WIRE SHORT TO VOLTAGE BODY CONTROL MODULE - SHORT TO VOLTAGE TEST ACTION APPLICABILITY 1 Turn the ignition on. t, record and erase DTC’s. With the DRBIII t, enter PROGRAM RKE. With the DRBIII t, read DTCs. Does the DRBIII t display RKE PROGRAM LINE OUTPUT SHORT? All Yes → Go To 2 No → Using the wiring diagram/schematic as a guide, inspect the wiring and connectors for an intermittent condition. 2 Disconnect the Remote Keyless Entry Module connector. t, erase DTCs. Cycle the ignition key and wait 30 seconds. t, read DTCs. Does the DRBIII t display RKE PROGRAM LINE OUTPUT OPEN? All No → Go To 3 Yes → Replace the Remote Keyless Entry Module. Perform BODY VERIFICATION TEST - VER 1. 3 Disconnect the Remote Keyless Entry Module connector. All Yes → Repair the RKE Module Program Enable wire for a short to voltage. No → Replace the Body Control Module. Perform BODY VERIFICATION TEST - VER 1. 795 POWER DOOR LOCKS/RKE |