Symptom: RIGHT UNLOCK OUTPUT FAILURE When Monitored and Set Condition: RIGHT UNLOCK OUTPUT FAILURE When Monitored: At all times when battery power is supplied to the Body Control Module. Set Condition: When the BCM senses a short condition on the right side door unlock circuits for over 125 milliseconds. POSSIBLE CAUSES DTC PRESENT BODY CONTROL MODULE - RIGHT DOOR UNLOCK DRIVER SHORT TO GROUND RIGHT FRONT DOOR UNLOCK DRIVER SHORT TO GROUND RIGHT SLIDING DOOR UNLOCK DRIVER SHORT TO GROUND RIGHT FRONT DOOR LOCK MOTOR - SHORT TO GROUND RIGHT SLIDING DOOR LOCK MOTOR - SHORT TO GROUND TEST ACTION APPLICABILITY 1 With the DRBIII t, record and erase DTC’s. Cycle the ignition ON to OFF. t, read DTCs. Operate the door locks several times from the Right Door Lock Switch while t. Does the DRBIII t display RIGHT UNLOCK OUTPUT FAILURE? All Yes → Go To 2 No → Using the wiring diagram/schematic as a guide, inspect the wiring and connectors. 2 Disconnect the Body Control Module C2 connector. All Right Front Door Unlock under 1000.0 ohm Right Sliding Door Unlk under 1000.0 ohm Neither circuit under 1000.0 ohms. Replace the Body Control Module. 791 POWER DOOR LOCKS/RKE |