Page 31-7 C HAPTER 31:
M ETAL C ULVERTS
First Edition -January 2018
Backfill that is not subject to piping action is classified as non-erodible. Such backfill typically For non-erodible or erodible soils, the ratio of D 85 soil size to the size of the opening must be greater than 0.3 for medium to fine sand or 0.2 for uniform sand. These ratios need not be c. Water Tightness: The adjoining pipe ends in any joint shall not vary more than 13 mm in diameter or more than 38 mm in circumference for watertight joints. Water tightness may be specified for joints of any category, where needed, to satisfy other Table 31-3: Categories of Pipe Joint
Soil Condition
Non-erodible Erodible Joint Type Joint Type Joint Property Standard Special Standard Special Down Drain Shear Resistance 2% 5% 2% 5% 2% Moment Resistance 5% 15% 5% 15% 15% Tensile Resistance up 0 22.2 kN - 22.2 kN 22.2 kN Tensile Resistance – 2130 mm Diameters - 44.5 kN - 44.5 kN 44.5 kN Joint Overlap, 265 mm NA 265 mm NA NA Soil Tightness NA NA 0.3 or 0.2 0.3 or 0.2 0.3 or 0.2 31.5.3 Assembly of Long-span Structures Unless held in shape by cables, struts, or backfill, longitudinal seams shall be tightened when the a. For horizontal elliptic shapes having a ratio of top to side radii of three or less, the span and rise shall not deviate from the specified dimensions by more than 2 percent. b. For arch shapes having a ratio of top to side radii of three or more, the rise shall not deviate from the specified dimensions by more than 1 percent of the span. c. For all other long-span structures, the span and rise shall not deviate from the specified dimensions by more than 2 percent, or more than 125 mm, whichever is less. When required by structural design, the Contractor shall attach reinforcing ribs to the structural plate |