S

TEEL

 

 

 

Bar 

Designation 

Nominal Diameter 

Mm 

Nominal Area 

mm

2

 

Nominal Weight 

 kg/m 

Dia. 10 

10 

79 

0.617 

Dia. 12 

12 

113 

0.888 

Dia. 14 

14 

154 

1.21 

Dia. 16 

16 

201 

1.58 

Dia. 18 

18 

254 

2.00 

Dia. 20 

20 

314 

2.47 

Dia. 22 

22 

380 

2.98 

Dia. 25 

25 

491 

3.85 

Dia. 28 

28 

616 

4.83 

Dia. 32 

32 

804 

6.31 

Dia. 36 

36 

1018 

7.99 

Dia. 40 

40 

1257 

9.87 

Dia. 45 

45 

1590 

12.49 

Dia. 50 

50 

1963 

15.4 

 

Table 5-5: Standard wire reinforcement - nominal weights and areas 

Wire 

designation

 

Nominal 

diameter 

mm

 

Nominal 

area 

mm

2

 

Nominal 

weight 

kg/m

 

Area (mm

2

/m)

 

Center-to-center spacing, mm

 

50

 

75

 

100

 

150

 

200

 

250

 

300

 

350

 

400

 

MW13

 

4.0

 

12.6

 

0.099

 

252

 

168

 

126

 

84

 

63

 

50

 

42

 

36

 

32

 

MW16

 

4.5

 

15.9

 

0.125

 

318

 

212

 

159

 

106

 

80

 

64

 

53

 

45

 

40

 

MW20

 

5.0

 

19.6

 

0.154

 

392

 

261

 

196

 

131

 

98

 

78

 

65

 

56

 

49

 

MW24

 

5.5

 

23.8

 

0.187

 

476

 

317

 

238

 

159

 

119

 

95

 

79

 

68

 

60

 

MW28

 

6.0

 

28.3

 

0.222

 

566

 

377

 

283

 

189

 

142

 

113

 

94

 

81

 

71

 

MW33

 

6.5

 

33.2

 

0.260

 

664

 

443

 

332

 

221

 

166

 

133

 

111

 

95

 

83

 

MW38

 

7.0

 

38.5

 

0.302

 

770

 

513

 

385

 

257

 

193

 

154

 

128

 

110

 

96

 

S

TEEL

 

 

 

Wire 

designation

 

Nominal 

diameter 

mm

 

Nominal 

area 

mm

2

 

Nominal 

weight 

kg/m

 

Area (mm

2

/m)

 

Center-to-center spacing, mm

 

50

 

75

 

100

 

150

 

200

 

250

 

300

 

350

 

400

 

MW44

 

7.5

 

44.2

 

0.347

 

884

 

589

 

442

 

295

 

221

 

177

 

147

 

126

 

111

 

MW50

 

8.0

 

50.3

 

0.396

 

1006

 

671

 

503

 

335

 

252

 

201

 

168

 

144

 

126

 

MW57

 

8.5

 

56.7

 

0.445

 

1134

 

756

 

567

 

378

 

284

 

227

 

189

 

162

 

142

 

MW64

 

9.0

 

63.6

 

0.499

 

1272

 

848

 

636

 

424

 

318

 

254

 

212

 

182

 

159

 

MW71

 

9.5

 

70.9

 

0.556

 

1418

 

945

 

709

 

473

 

355

 

284

 

236

 

203

 

177

 

MW78

 

10.0

 

78.5

 

0.617

 

1570

 

1047

 

785

 

523

 

393

 

314

 

262

 

224

 

196

 

MW87

 

10.5

 

86.6

 

0.680

 

1732

 

1155

 

866

 

577

 

433

 

346

 

289

 

247

 

217

 

MW95

 

11.0

 

95.0

 

0.746

 

1900

 

1267

 

950

 

633

 

475

 

380

 

317

 

271

 

238

 

MW104

 

11.5

 

103.9

 

0.815

 

2078

 

1385

 

1039

 

693

 

520

 

416

 

346

 

297

 

260

 

MW113

 

12.0

 

113.1

 

0.888

 

2262

 

1508

 

1131

 

754

 

566

 

452

 

377

 

323

 

283

 

 

 

S

TEEL

 

 

 

I

NDEX

 

adhesion, 5-6, 5-7, 5-15 
bend diameters, 5-12 
Billet-Steel, 5-1, 5-4, 5-9, 5-17 
Binding wire, 5-5, 5-8 
Certificate, 5-7, 5-15 
chemical analysis, 5-11, 5-13 
chromium, 5-9, 5-10, 5-12, 5-13, 5-17 
coated, 5-1, 5-4, 5-5, 5-6,  5-7, 5-12, 5-13, 5-

14, 5-15, 5-16 

concrete reinforcing. See reinforcing steel 
Corrosion-Resistant, 5-9, 5-17 
cracking, 5-6, 5-7, 5-15 
Deformed, 5-1, 5-4, 5-8, 5-9, 5-12, 5-13, 5-17 

Epoxy

5-1

, 5-4, 5-5, 5-7, 5-13, 5-15 

film thickness, 5-5 
Fractures, 5-7 
Hook dimensions, 5-12 
Independent testing, 5-10 
laboratory, 5-5, 5-9, 5-10, 5-11 
low carbon, 5-9 
mechanical splices, 5-17 
Mechanical splices, 5-11 
mill certificate, 5-8 

pin diameter, 5-12 
post-tensioned members, 5-1 
precast concrete blocks, 5-14 
quality, 5-8, 5-9, 5-10, 5-11 
reinforcement, 5-1, 5-4, 5-5, 5-8, 5-12, 5-13, 5-

14, 5-15, 5-16, 5-17, 5-18 

reinforcing steel, 5-1 
resin powders, 5-5 
sample, 5-5, 5-7, 5-11, 5-15, 5-16 
Sampling, 5-1 
spirals, 5-1, 5-8 
splices, 5-16, 5-17 
stainless steel, 5-8, 5-9 
steel, 5-1, 5-4, 5-5, 5-7, 5-8, 5-9, 5-10, 5-12, 5-

13, 5-14, 5-15, 5-16, 5-17 

Testing, 5-1, 5-10, 5-11, 5-16 
Tolerances, 5-12 
uncoated, 5-1, 5-13, 5-14, 5-16 
weight, 5-9, 5-11, 5-14, 5-17, 5-18 
welded wire fabric, 5-4, 5-7, 5-14, 5-17 
Wire bar supports, 5-14 
wire mesh, 5-1 

 

 

 

 

 

 

 

 

 

 

STANDARD CONSTRUCTION SPECIFICATIONS 

PART 1 

ROADS 

 

CHAPTER 6 - MASONRY 

 

 

 

 

 

 

 

DOCUMENT

 

NO:

 

TR-542-1 

SECOND

 

EDITION 

SEPTEMBER

 

2020

 

 

 

 

 

 

Chapter 6: Masonry

 

T

ABLE OF 

C

ONTENTS

 

Table of Contents............................................................................................................................. i

 

List of Figures .................................................................................................................................. ii

 

List of Tables ................................................................................................................................... ii

 

6

 

MASONRY ........................................................................................................................ 6-1

 

6.1

 

Reference Standards and Codes ................................................................................... 6-1

 

6.2

 

Concrete Block and Brick Masonry ................................................................................ 6-2

 

6.2.1

 

Description ................................................................................................................. 6-2

 

6.2.2

 

Materials .................................................................................................................... 6-2

 

6.2.2.1

 

Concrete Block ................................................................................................ 6-2

 

6.2.2.2

 

Brick ................................................................................................................ 6-2

 

6.2.2.3

 

Concrete Masonry Units .................................................................................. 6-2

 

6.2.2.4

 

Reinforcing Steel ............................................................................................. 6-2

 

6.2.2.5

 

Mortar and Grout ............................................................................................. 6-3

 

6.2.3

 

Construction ............................................................................................................... 6-3

 

6.2.3.1

 

General ............................................................................................................ 6-3

 

6.2.3.2

 

Mixing Mortar ................................................................................................... 6-4

 

6.2.3.3

 

Laying Block and Brick..................................................................................... 6-4

 

6.2.3.4

 

Placement of Reinforcement ............................................................................ 6-5

 

6.2.3.5

 

Grouting of Voids ............................................................................................. 6-5

 

6.2.3.6

 

Copings, Bridge Seats, and Backwalls ............................................................. 6-6

 

6.2.3.7

 

Ashlar Stone Copings ...................................................................................... 6-6

 

6.2.3.8

 

Concrete Copings ............................................................................................ 6-8

 

6.2.3.9

 

Weep Holes ..................................................................................................... 6-8

 

6.3

 

Rock Masonry ................................................................................................................ 6-8

 

6.3.1

 

Description ................................................................................................................. 6-8

 

6.3.2

 

Materials .................................................................................................................... 6-8

 

6.3.2.1

 

Rock for Masonry Structures............................................................................ 6-8

 

6.3.3

 

Construction Requirements ........................................................................................ 6-9

 

6.3.3.1

 

Rock Walls ..................................................................................................... 6-11

 

6.3.3.2

 

Facing for Concrete ....................................................................................... 6-11

 

6.3.3.3

 

Masonry Guardwall ........................................................................................ 6-12

 

Index  6-13

 

 
 

 

 

 

 

MASONRY  

This work shall consist of furnishing, placing, and constructing concrete blocks, brick masonry, and 
rock masonry in accordance with these specifications and conforming to the dimensions shown in 
the Contract documents.  

6.1 

Reference Standards and Codes 

Standards  and  codes  for  masonry  works  shall  be  as  specified  in  these  specifications,  in  the 
Contract documents, if any, and the following, in their latest edition: 

AASHTO 

American Association of State Highway and Transportation Officials - Roadside 
Design Guide; 

AASHTO 

Standard Specifications for Transportation Materials and Methods of Sampling 
and Testing; 

ASTM 

American Society for Testing and Materials; 

FHWA 

Federal Highway Administration, Eastern Federal Lands Highway Divison, 1996; 

BSI 

British Standards Institution; 

BS EN 

European Standards. 

Table  6-1  and  Table  6-2  presents  American  Association  of  State  Highway  and  Transportation 
Officials  (AASHTO),  American  Society  for  Testing  and  Materials  (ASTM),  British  (BS),  and 
European  (BS  EN)  Standards  that  are  related  to  materials  for  masonry  works.  It  also  includes 
designations and titles. 

Table 6-1: Designations and titles for AASHTO and ASTM standards that apply to masonry 

works 

AASHTO 

DESIGNATION

 

ASTM 

DESIGNATION

 

TITLE

 

AASHTO M 

114-07 

ASTM C62 - 12 

Standard  Specification  for  Building  Brick  (Solid  Masonry 
Units Made from Clay or Shale).  

 

ASTM C55 - 11 

Standard Specification for Concrete Building Brick. 

 

ASTM C90 - 

11b 

Standard Specification for Loadbearing Concrete Masonry 
Units.  

 

ASTM C139 - 

10 

Standard  Specification  for  Concrete  Masonry  Units  for 
Construction of Catch Basins and Manholes.  

 

ASTM C780 - 

11 

Standard 

Test 

Method 

for 

Preconstruction 

and 

Construction  Evaluation  of  Mortars  for  Plain  and 
Reinforced Unit Masonry.  

AASHTO T 22-

10 

 

Compressive Strength of Cylindrical Concrete Specimens. 

 

ASTM C39 / 

C39M - 11 

Standard  Test  Method  for  Compressive  Strength  of 
Cylindrical Concrete Specimens. 

 

ASTM C270 - 

12 

Standard Specification for Mortar for Unit Masonry.  

 

ASTM A884 / 

A884M - 06 

Standard  Specification  for  Epoxy  Coated  Steel  Wire  and 
Welded Wire Reinforcement.  

 

 

 

Table 6-2: Designations and titles for BS and BS EN standards that apply to masonry works 

BS Designation 

BS EN 

Designation 

Title 

 

BS EN 1015-

10:1999 

Methods of test for mortar for masonry. Determination of 
dry bulk density of hardened mortar.  

6.2 

Concrete Block and Brick Masonry 

6.2.1 

Description 

Concrete block and brick masonry shall consist of concrete blocks or brick laid in cement mortar, 
and  may  be  unreinforced  or  reinforced  with  steel.  Block  and  brick  pavements  are  not  included 
under this designation. 

6.2.2 

Materials 

6.2.2.1 

Concrete Block 

Concrete  blocks  shall  be  hard,  durable,  and  clean  with  sharp,  well-defined  edges,  and  free  from 
any  cracks,  flaws,  or  other  defects.  Unless  otherwise  specified  in  the  Contract  Documents,  their 
dimensions shall be 400 mm long by 200 mm wide by 200 mm tall, or such other dimensions shall 
be approved by the Engineer. 

Unless otherwise specified in the  Contract Documents or approved in writing by the  Engineer, all 
concrete block for masonry construction shall be Type I moisture controlled units (Grade N-I) that 
meet  the  requirements  of  ASTM  C90 

–  11b.  The value  of 

m

  (specified  compressive  strength  of 

masonry)  shall  be  as  shown  in  the  Contract  Documents  and  shall  be  verified  by  means  of  prism 
testing.  Prism shall be a sample assembly of masonry units, mortar joints and grout. 

Concrete block units should be protected from rain or other moisture during storage on or off the 
job site to ensure that they will meet the Type I moisture requirements at the time they are placed 
during construction. 

6.2.2.2 

Brick 

Brick for masonry construction shall conform to the Specification for Building Brick (solid masonry 
units  made  from  clay  or  shale)  AASHTO  M  114  -07  (ASTM  C62  -  12),  Concrete  Building  Brick 
(ASTM  C55  -  11),  or  Solid  Load-Bearing  Concrete  Masonry  Units  (ASTM  C90 

–  11b).  Type  and 

grade of the brick to be furnished shall be as specified in the Contract Documents. 

Bricks shall have a fine-grained, uniform, and dense structure, free from lumps of lime, laminations, 
cracks, checks, soluble salts, or other defects that may in any way impair their strength, durability, 
appearance,  or usefulness for the purpose intended.  Bricks shall emit a clear, metallic ring when 
struck with a hammer. 

6.2.2.3 

Concrete Masonry Units 

Concrete  masonry  units  for  use  in  manholes,  inlets,  and  similar  structures  shall  meet  the 
requirements of ASTM C139 - 10. 

6.2.2.4 

Reinforcing Steel 

Reinforcing steel shall be of the strength, spacing, dimensions and type as shown in the  Contract 
plans. Reinforcing steel used in the construction of concrete block or brick masonry structures shall 
conform  to  the  applicable  requirements  for  reinforcing  in  Chapter  5,  Reinforcing  Steel,  of  these 
standard specifications. 

 

 

 

6.2.2.5 

Mortar and Grout 

Mortar  and  grout  ingredients  and  mix  design  shall  meet  the  requirements  of  Article  4.3.10.4  of 
Chapter 4, Concrete Works, of these standard specifications, for the class and application types as 
otherwise  specified  in  these  Standard  Specifications,  as  shown  on  the  Contract  plans  or  as 
included in the Particular Specifications. 

a.  Sampling and Testing 

Grout  and  mortar  testing  shall  meet  the  sampling  and  testing  requirements  specified  in  Article 
4.3.10.4 of Chapter 4, Concrete Works, of these standard specifications, and as may be modified 
by the requirements below, if so directed by the Engineer. 

1.  Mortar 

Unless otherwise specified in the Particular Specifications or shown on the Contract plans, 
mortar  shall  have  a  minimum  28-day  compressive  strength  of  12.5  mPa,  based  on  the 
average  of  three  specimens  tested  in  accordance  with  the  requirements  of  ASTM  C780  - 
11. Field samples shall be obtained using the following procedure: 

i.  Spread 12.5 mm or the thickness of the mortar joint of mortar on masonry units. 

ii.  After one minute, remove the mortar and compress it into a 50 mm by 100 mm cylinder 

(or equivalent cube as per test procedure per BS EN 1015-10:1999) in two layers using 
the flat end of a rod or fingers, being sure to see that the mold is solidly filled. 

iii.  Lightly tap the cylinder immediately, and maintain it in a damp condition. 

iv.  After 48 hours, remove the mold and store it in clean water until testing. 

2.  Grout 

When  required  by  the  Contract  documents  or  requested  by  the  Engineer,  the  Contractor 
shall manufacture grout prisms for testing. Prisms shall be manufactured at the site during 
construction using the following procedure: 

i.  Place masonry units that have the same moisture condition as those already placed on a 

non-absorptive base to form a void for a square prism, with a height twice the side of the 
masonry unit and a minimum side of 75 mm. 

ii.  Line  the  side  faces  of  the  prism  with  a  permeable  paper  or  porous  separator  to  allow 

water passage through the liner into the masonry units. 

iii.  Fill the prism with a fully-representative grout sample in two layers. Puddle each layer to 

eliminate air voids. 

iv.  Level off the specimen and maintain it in a damp condition. 

v.  Remove  the  prisms  from  the  masonry  units  after  48  hours  and  deliver  them  to  the 

Engineer. 

Grout  prisms  shall  be  tested  in  accordance  with  the  provisions  of  AASHTO  T  22  -  10 
(ASTM C39/C39M - 11). Grout shall have attained a compressive strength of 13.8 MPa at 
28 days, unless otherwise specified in the Contract Documents. 

6.2.3 

Construction 

6.2.3.1 

General 

a.  Brick Masonry 

Foundations shall be constructed firm and dry. All brick shall be damp at the time of laying. Bricks 
shall be laid in courses in full, close, uniform joints of mortar. Adjoining courses shall break joints 
by  one-half  length,  as  near  as  practicable.  Courses  shall  be  level  in  all  places,  except  where 

 

 

 

otherwise  directed.  All  exposed  surfaces  shall  be  smooth  and  clean,  and  the  tie  joint  shall  not 
exceed 12.5 mm in width. Broken or chipped bricks shall not be used in the faces of the masonry. 
Joints  shall  be  cleaned  and  pointed  before  the  mortar  sets.  Exposed  surfaces  of  the  bricks  shall 
not be smeared with mortar forced out of the joints or that used in pointing, but shall be kept clean 
and  free  from  mortar  stains.  For  straight  masonry  walls,  at  least  one  course  in  seven  shall  be  a 
header course. 

b.  Concrete Block Masonry 

When shown on the Contract plans and/or in the Particular Specifications, masonry walls may be 
constructed of hollow concrete blocks instead of bricks. Applicable construction details shall be the 
same as for brick masonry. 

c.  Manholes, Inlets, and Catch Basins 

Brick  masonry  for  manholes,  inlets,  and  catch  basins  shall  conform  to  details  shown  on  the 
Contract  plans.  Construction  requirements  shall  be  as  specified  in  Section  12.4  of  Chapter  12, 
Storm  Water  Drainage,  of  these  standard  specifications.  Where  shown  on  the  Contract  plans,  a 
plaster coat shall be applied to the faces of these and similar structures. Mortar for this coat shall 
be  of  the  same  mix  as  used  in  laying  the  brick,  and  the  coat  shall  be  no  less  than  6  mm  thick. 
Before  applying  the  plaster  coat,  the  brick  shall  be  thoroughly  wetted  and  the  surface  allowed  to 
dry sufficiently to ensure a proper bond of the plaster coat. 

Full  mortar  beds  shall  be  provided  for  setting  castings  required  by  the  Contract  plans.  Castings 
shall be set carefully to the required elevations. 

6.2.3.2 

Mixing Mortar 

Proportions of materials, water retention, workability, and related requirements shall be in such a 
manner as to produce the specified strength. Before commencing work, the Contractor shall have 
the  mortar  mix  approved  by  the  Engineer.    Mortar  mix  and  mixing  requirements  shall  meet  the 
requirements  included  in  Article  4.3.10.4  of  Chapter  4,  Concrete  Works,  of  these  standard 
specifications, and as specified herein. 

Mortar shall be hand- or machine-mixed, as may be required by the Engineer. In the preparation of 
hand-mixed  mortar,  the  sand  and  cement  shall  be  thoroughly  mixed  together  in  a  clean,  tight 
mortar  box  until  the  mixture  is  of  uniform  color,  after  which  clean  water  shall  be  added  in  such 
quantity  as  to  form  a  stiff  plastic  mass.  Machine-mixed  mortar  shall  be  prepared  in  an  approved 
mixer  and  shall  not  be  mixed  less  than  three  minutes  or  more  than  10  minutes.  Mortar  shall  be 
used within 1.5 hours after mixing and before final setting begins. Re-tempering of mortar shall be 
performed as necessary to maintain proper consistency during placement. 

6.2.3.3 

Laying Block and Brick 

Blocks  or  bricks  shall  be  laid  in  such  a  manner  as  will  thoroughly  bond  them  into  the  mortar  by 
means of the “shove-joint” method; “buttered” or plastered joints shall not be permitted. All clay or 
shale  brick  shall  be  thoroughly  saturated  with  water  before  being  laid.  Dampening  of  concrete 
masonry  units  before  or  during  construction  shall  not  be  permitted  unless  approved  by  the 
Engineer.  Headers  and  stretchers  shall  be  arranged  to  thoroughly  bond  the  mass,  and  unless 
otherwise  specified,  alternate  headers  and  stretchers  shall  be  used  with  consecutive  courses 
breaking joints. Other types of bonding, as for ornamental work, shall be as may be specified in the 
Particular Specifications or as shown on the Contract plans. 

All joints shall be completely filled with mortar. They shall not be less than 6 mm wide and not more 
than 19 mm thick, with the thickness uniform throughout. All joints shall be finished properly as the 
work progresses, using the “weather” joint. Exposed faces shall be neatly struck. 

No spalls or bats shall be used except for shaping around irregular openings or when unavoidable 
to finish out a course, in which case full bricks shall be placed at the corners, with the bats placed 
in the interior of the course. 

 

 

 

Each  masonry  unit  shall  be  adjusted  to  its  final  position  while  the  mortar  is  still  soft  and  plastic. 
Units  that  are  disturbed  after  the  mortar  has  stiffened  shall  be  removed  and  laid  again  in  fresh 
mortar. 

Vertical cells to be filled with grout shall be aligned to provide a continuous unobstructed opening. 

Piers and walls may be built of solid brick work, or may consist of a brick or block shell backed with 
concrete or other suitable material as shown on the Contract plans. All details of the construction 
shall be in accordance with approved practices and to the satisfaction of the Engineer. 

6.2.3.4 

Placement of Reinforcement 

Prior to and during grouting, the reinforcing steel shall be securely held in position at the top and 
bottom and at intermediate points not exceeding 200 bar diameters or 3 meters apart. Bars shall 
be  maintained  clear  of the  cell  walls  and  within ±12.5  mm  of  their  planned  position transverse  to 
the wall and within ±50 mm of their planned position longitudinal to the wall. 

6.2.3.5 

Grouting of Voids 

Grouted  masonry  shall  be  constructed  in  such  a  manner  that  all  elements  of  the  masonry  acts 
together as one structural element. 

Prior  to  grouting,  the  grout  space  shall  be  clean  so  that  all  spaces  to  be  filled  with  grout  do  not 
contain mortar projections greater than 12.5 mm, mortar droppings, or other foreign material. Grout 
shall be placed so that all spaces to be grouted do not contain voids. 

Grout  materials  and  water  content  shall  be  controlled  to  provide  adequate  fluidity  for  placement 
without segregation. 

Size  and  height  limitations  of  the  grout  space  or  cell  on  the  average  shall  not  be  less  than  as 
shown in Table 6-3. Higher grout pours or smaller cavity widths or cell sizes than shown in Table 6-
may be used when approved by the Engineer, if it is demonstrated that grout spaces are properly 
filled. 

When required by Table 6-3, cleanouts shall be provided in the bottom course at every vertical bar, 
but shall not be spaced more than 813 mm on center for solidly grouted masonry. Cleanouts shall 
be of sufficient size to allow removal of debris. 

Units may be laid to the full height of the grout pour, and grout shall be placed in a continuous pour 
in grout lifts not exceeding 1.8 meters. If construction joints are used in columns of grout, they shall 
be located at least 38 mm below the level of a mortar bed joint. 

Segregation  of  the  grout  materials  and  damage  to  the  masonry  shall  be  avoided  during  the 
grouting process. 

Grout shall be consolidated before the loss of plasticity in a manner to fill the grout space. Grout 
pours greater than 300 mm in height shall be mechanically reconsolidated to minimize voids due to 
water loss. Grout not mechanically vibrated shall be puddled. 

In  non-structural  elements,  mortar  of  pouring  consistency  may  be  substituted  for  grout  when  the 
masonry is constructed and grouted in pours of 300 mm or less. 

Vertical  barriers  of  masonry  may  be  built  across the  grout  space. Grouting  of  any  section  of  wall 
between barriers shall be completed in one day with no interruption longer than one hour. 

Table 6-3:  Grouting limitations 

 

 

Least Clear Dimensions 

 

Grout 

Type 

Grout Pour Maximum 

Height 

metre 

Width of Grout Space,  

mm 

Cell 

Dimensions, 

mm × mm 

Cleanouts 

Required 

Fine 

0.3 

19 

38 × 50 

No 

 

 

 

 

 

Least Clear Dimensions 

 

Grout 

Type 

Grout Pour Maximum 

Height 

metre 

Width of Grout Space,  

mm 

Cell 

Dimensions, 

mm × mm 

Cleanouts 

Required 

Fine 

1.5 

38 

38 × 50 

No 

Fine 

2.4 

38 

38 × 76 

Yes 

Fine 

3.6 

38 

44 × 76 

Yes 

Fine 

7.3 

50 

76 × 76 

Yes 

Coarse 

0.3 

38 

38 × 76 

No 

Coarse 

1.5 

50 

63 × 76 

No 

Coarse 

2.4 

50 

76 × 76 

Yes 

Coarse 

3.6 

63 

76 × 76 

Yes 

Coarse 

7.3 

76 

76 × 101 

Yes 

6.2.3.6 

Copings, Bridge Seats, and Backwalls 

In general, tops of retaining walls, abutment wingwalls, and similarly exposed brick or block work 
shall be provided, with either a stone or concrete coping as specified in the Contract documents. 
Underside of coping shall have a batter or drip bead at least 25 mm beyond the face of the block or 
brick  work  wall.  Coping  on  an  abutment  backwall  shall  commonly  have  no  projection  beyond  its 
bridge  seat  face.  Unless  otherwise  specified,  when  concrete  is  used,  it  shall  conform  to  the 
requirements  for  Class  C35/20  concrete  specified  in  Section  4.3.9  and  other  applicable 
requirements  of  Chapter  4,  Concrete  works.  For  thin  copings,  mortar  of  the  same  proportions  as 
used for laying the block or brick may be used to produce precast sections no less than 0.9 m or 
more than 1.5 m in length. No coping shall be less than 100 mm thick. 

Copings of piers and abutment bridge seats may be of ashlar stone work or of concrete conforming 
to  the  requirements  of  Articles  6.2.3.7  and  6.2.3.8  respectively.  Unless  otherwise  shown  in  the 
Contract documents, concrete shall be used. 

6.2.3.7 

Ashlar Stone Copings 

Ashlar  masonry  is  composed  of  rectangular  stones  laid  with  mortar  in  horizontal  courses.  Ashlar 
masonry shall consist of first-class cut stone masonry laid in regular courses, and shall include all 
work in which the individual stones (as distinguished from rubble masonry) are dressed or tooled to 
exact dimensions. 

Stone for ashlar masonry shall be reasonably fine grained and uniform in color. Preferably, stone 
shall be from a quarry, the product of which is known to be of satisfactory quality. Stone shall be of 
such character that it can be brought to such lines and surfaces, whether curved or plane, as may 
be required. Any stone having defects that have been repaired with cement or other materials shall 
be rejected. 

Each  stone  shall  be  free  from  depressions  and  projections  that  might  weaken  or  prevent  it  from 
being properly bedded, and shall be of a shape to meet the requirements for the class of masonry 
specified. 

Stones for copings of wall, pier, and abutment bridge seats shall be carefully selected and be fully-
dimensioned stones. On piers, not more than two stones shall be used to make up the entire width 
of coping. Copings of abutment bridge seats shall be of sufficient width to extend at least 100 mm 
under the backwall. Each step forming the coping of a wingwall shall be formed by a single stone 
that shall overlap the stone forming the step immediately below it by at least 300 mm. 

 

 

 

Tops  of  copings  shall  be  given  a  bevel  cut  at  least  50 mm  wide,  and  beds,  bevel  cuts,  and  tops 
shall  be  fine-finished.  Vertical  joints  shall  be  smooth-finished,  and  the  copings  shall  be  laid  with 
joints  no  more  than  6.5 mm  thick.  Preferably,  undersides  of  projecting  copings  shall  have  a  drip 
bead. 

Joints in copings shall be located so as to provide no less than a 300 mm bond with the stones of 
the under course, and so that no joint will come directly under the superstructure masonry plates. 

a.  Shipment and Storage of Stone 

Quarry operations and delivery of stone to the point of use shall be organized to ensure deliveries 
well ahead of masonry operations. Sufficiently large stocks of the specified stone shall be kept on 
the site at all times to permit adequate selection of stone by the masons. 

All stone shall be kept free from dirt, oil, or any other injurious material that may prevent the proper 
adhesion of the mortar or detract from the appearance of the exposed surfaces. 

b.  Surface Finishes of Stone 

Stone surface finishes are defined as follows: 

1.  Smooth-finished: Having a surface in which the variations from the pitch line do not exceed 

1.5 mm. 

2.  Fine-finished: Having a surface in which the variations from the pitch line do not exceed 6.5 

mm. 

3.  Rough-finished: Having a surface in which the variations from the pitch line do not exceed 

12.5 mm. 

4.  Scabbled:  Having  a  surface  in  which  the  variations  from  the  pitch  line  do  not  exceed 

19 mm. 

5.  Rock-faced:  Having  an  irregular  projecting  face  without  indications  of  tool  marks. 

Projections  beyond  the  pitch  line  shall  not  exceed  76 mm  and  no  part  of  the  face  shall 
recede back of the pitch line. 

c.  Selection and Placing of Stone 

Each  stone  shall  be  cleaned  and  thoroughly  saturated  with  water  before  being  set,  and  the  bed 
that  is  to  receive  it  shall  be  clean  and  well  moistened.  All  stones  shall  be  well-bedded  in  freshly 
made mortar. Mortar joints shall be full and the stones carefully settled in place before the mortar 
has  set.  No  spalls  shall  be  permitted  in  the  beds.  No  pinning  up  of  stones  with  spalls  shall  be 
permitted in beds. 

Stone  shall  not  be  dropped  upon  or  slid  over  the  wall,  nor  will  hammering,  rolling,  or  turning  of 
stones on the wall be permitted. Stone shall be carefully set without jarring the stone already laid, 
and shall be handled with a Lewis tool or other appliance that will not cause disfigurement. 

In case any stone is moved or the joint broken, the stone shall be taken up, the mortar thoroughly 
cleaned from the bed and joints, and the stone reset in fresh mortar. 

d.  Dowels and Cramps 

Where required, coping stone, stone in the wings of abutments, and stone in piers shall be secured 
with wrought-iron cramps or dowels as indicated in the Contract plans. 

Dowel holes shall be drilled through each stone before the stone is placed and, after it is in place, 
such dowel holes shall be extended by drilling into the underlying course not less than 150 mm. 

Cramps  shall  be  of  the  shapes  and  dimensions  shown  in  the  Contract  plans  or  approved  by  the 
Engineer. They shall be inset in the stone so as to be flush with the surfaces. 

Cramps and dowels shall be set in lead, care being taken to completely fill the surrounding spaces 
with the molten metal, or shall be rigidly anchored by other means approved by the Engineer. 

 

 

 

6.2.3.8 

Concrete Copings 

Copings, bridge seats, and backwalls shall be of the material specified in the Contract documents, 
and  when  not  otherwise  specified,  shall  be  of  C35/20  concrete,  which  shall  conform  to  the 
requirements of Section 4.3.9 and other applicable requirements of Chapter 4, Concrete Works, of 
these standard specifications. 

Concrete  copings  shall  be  made  in  sections  extending  the  full  width  of  the  wall,  no  less  than 
300 mm  thick,  and  from  1.5  to  3.0  m  long,  or  as  shown  on  the  Contract  plans.  Sections  may  be 
cast-in-place or precast and set in place in full mortar beds. 

6.2.3.9 

Weep Holes 

All  walls  and  abutments  shall  be  provided  with  weep  holes.  Unless  otherwise  specified  in  the 
Contract  documents  or  directed  by  the  Engineer,  the  weep  holes  shall  be  placed  at  the  lowest 
points  where  free  outlets  can  be  obtained,  and  shall  be  spaced  no  more  than  3.0 m  center-to-
center. At each weep hole, a minimum of 0.057 m

3

 of permeable material encapsulated with filter 

fabric shall be placed. 

6.3 

Rock Masonry 

6.3.1 

Description 

Rock  masonry  shall  consist  of  rock  laid  in  a  bed  of  mortar,  dressed,  pointed,  cured,  and 
constructed in conformance to the Contract plans, the Particular Specifications, the direction of the 
Engineer, and these Standard Specifications.   

6.3.2 

Materials 

Rock masonry materials shall conform to the requirements established in Table 6-4.   

Table 6-4: Material requirements for rock masonry

 

Material 

Requirements 

Cement, fly ash, admixtures 

Section 4.3 of Chapter 4, Concrete Works. 

Mortar 

Article 4.3.10.4 of Chapter 4, Concrete Works 

ASTM C270 - 12, Type M or S only 

Class G6  grout  

Article 4.3.10.4 of Chapter 4, Concrete Works 

Maximum water-to-cement ratio of 0.44.   

6.3.2.1 

Rock for Masonry Structures 

Contractor shall furnish sound, durable rock that meets the requirements of the  Contract plans or 
as required in the Particular Specifications.  Rock native to the vicinity of the work similar in texture 
and  colour  to  native  rock  is  preferred.  Dimensioned  masonry  rock  shall  be  free  of  reeds,  rifts, 
seams,  laminations,  and  minerals  that  may  cause  discolouration  or  deterioration.  Rock  with 
depressions or projections that might weaken it or prevent it from being properly bedded shall not 
be used.  Contractor shall submit samples to the Engineer for approval and construction shall not 
begin until written approval is received.  

Rocks  shall  be  furnished  in  the  sizes  and  face  areas  necessary  to  produce  the  general 
characteristics and appearance indicated on the  Contract plans. Unless otherwise specified, rock 
fragments shall meet the dimensional requirements in Table 6-5.   

 

 

 

 

 

Table 6-5: Physical requirements for rock for masonry 

Dimension 

Requirements 

Minimum thickness 

125 mm 

Minimum width 

300 mm or 1.5 times the thickness, whichever is greater 

Minimum length 

1.5 times the width 

At least half of the rocks shall have a volume greater than, or equal to, 0.03 m

3

. When headers are 

required, furnish headers with lengths no less than the width of bed of the widest adjacent stretcher 
plus 300 mm. 

6.3.3 

Construction Requirements 

Excavation and backfill shall be performed per  Sections 2.4 and 2.5 of Chapter 2, Earthworks, of 
these standard specifications. Foundation bed shall be prepared normal to, or in steps normal to, 
the  face  of  the  masonry.  Where  foundation  masonry  is  used,  the  bearing  surface  shall  be 
thoroughly cleaned and shall be wetted immediately before spreading the mortar bed.  

Prior to placing rocks, the Contractor shall clean and moisten the bed. 

Unless  otherwise  shown  on  the  Contract  plans,  mortar  shall  be  proportioned  and  supplied  per 
ASTM C270 - 12, Type M or S only, and may be preblended or mixed on site.  Mortar bed shall not 
lay longer than 45 minutes or until mortar begins to set before placing rock. 

Rocks shall be placed to provide a uniform pattern and color. To provide sufficient variety of rocks 
for the masons, the Contractor shall maintain an adequate inventory of the rock on site. When rock 
is  added,  the  new  rock  shall  be  mixed  with  the  existing  rock  in  a  uniform  pattern  and  color.  All 
rocks shall be cleaned thoroughly and moistened immediately before placing. When removing and 
resetting rock masonry, the Contractor shall use hand tools to clean the exposed faces of the rocks 
of all mortar before resetting. 

Mortar  shall  be  spread to  the thicknesses  of  beds  and  joints  for face  stones  shown  in  Table 6-6. 
Bed of each course shall be uniform in thickness. 

Joints in dimensioned masonry shall be vertical. In all other masonry, joints may be at angles with 
the vertical from 0

o

 to 45

o

Cross beds for vertical walls shall be level. Beds for battered walls may vary from level to normal to 
the batter line of the face of the wall. 

Rocks shall be laid with the longest face horizontal and the exposed face parallel to the masonry 
face, and then the joints shall be flushed with mortar. 

Contractor  shall  take  care  to  not  jar  or  displace  rocks  that  are  already  set.  If  a  rock  is  loosened 
after the mortar has taken initial set, it shall be removed, cleaned of mortar, and relaid with fresh 
mortar. 

Dressing shall remove all thin or weak portions.  Face rock bed and joint lines shall be dressed to 
the maximum variation from true line shown in Table 6-6.  The Contractor shall dress face rock as 
follows:  

a.  Dress bed surfaces to a depth of 75 mm, normal to the face, after which the departure from 

normal may not exceed 25 mm in 300 mm for dimensioned masonry or 50 mm in 300 mm 
for all other classes.   

b.  Dress joint surfaces normal to the face to a depth of 50 mm, after which the departure from 

normal may not exceed 25 mm in 300 mm.  

 

 

 

Table 6-6: Rock masonry classes and construction requirements 

Class 

Stones and 

Laying 

Bed 

Thickne

ss 

(mm) 

Joint 

Thickne

ss 

(mm) 

Dressing 

(mm from true 

line, angle to bed) 

Rounding 

corners where 

bed and joint 

lines meet 

Dimensione

d masonry 

Stones are cut in 

≥ 2 dimensions, 

laid in  broken-

course pattern 

10 to 25 

19 to 25 

Reasonably true, 

normal to bed 

No rounding 

Class A 

masonry 

Stones are 

shaped, dressed 

to 5 mm 

13 to 50 

13 to 38 

5 mm, 

≥ 45

o

 to bed 

surface 

No rounding 

Class B 

masonry 

Stones are 

shaped, dressed 

to 20 mm 

13 to 50 

13 to 50 

20 mm, ≥ 45

o

 to 

bed surface 

Radii ≤  25 mm 

 

Rubble 

masonry 

Stones vary in 

size and shape, 

laid in random 

courses 

13 to 64 

13 to 64 

40 mm, ≥ 45

o

 to 

bed surface 

Radii ≤  40 mm 

 

To  finish  exposed  surfaces,  the  Contractor  shall  remove  all  drill  or  quarry  marks  from  exposed 
faces  and  pitch  face  stones  to  the  line  along  all  beds  and  joints.    Classes  for  finishing  exposed 
faces  are  as  defined  in  Table  6-7,  and  shall  be  executed  as  shown  in  the  Contract  plans  or  the 
Particular Specifications, or as directed by the Engineer.  

Table 6-7: Rock masonry finishing classes 

Class 

(abbreviation) 

Approximate 

spacing for point 

depressions 

Maximum surface 

variation from the pitch 

line 

Appearance 

Fine pointed (FP) 

10 mm 

±3 mm 

 

Medium pointed 
(MP) 

15 mm 

±5 mm 

 

Coarse pointed 
(CP) 

30 mm 

±10 mm 

 

Split or seam face 
(S) 

+20 mm 

-0mm 

Smooth, no tool marks 

Rock faced (RF) 

+Defined* 

-0 mm 

Irregular, no tool marks, 
projections with no 
concave surfaces below 
the pitch line

*Projections  beyond  the  pitch  line  shall  be  specified,  i.e.  “Class  40RF”  means  no  projections  exceeding 
40mm  beyond  the  pitch  line.    Where  a  "variable  rock  face"  is  specified,  the  Contractor  shall  uniformly 
distribute stones of the same height of projection. 

To point  new joints, the Contractor shall crown the mortar  in the joints on top surfaces slightly at 
the  centre  of  the  masonry  for  drainage.  For  raked  joints,  the  Contractor  shall  squarely  rake  all 
mortar in exposed face joints and beds to the required depth. For weather joints, the joints shall be 
slightly  raked.  Mortar shall  not remain  flush  with  the rock  faces.  All  face  rock  shall  be  cleaned  of 
mortar stains while the mortar is fresh. After the mortar sets, the Contractor shall clean again using 
wire brushes and acid. Masonry shall be protected during hot or dry weather kept wet for at least 3 
days after the work is completed. 

To  repoint  joints,  the  Contractor 

shall  remove  loose  mortar  from  joints  using  a  small  mason’s 

chisel,  small  pneumatically-power  chisel,  or  other  raking  tool  approved  by  the  Engineer.  Power 

 

 

 

 

 

 

 