A/C SYSTEM GENERAL DIAGNOSTIC PROCEDURES 

         1993 AIR CONDITIONING & HEAT
         A/C General Diagnostic Procedures

         Diagnosis is an important first step in A/C system servicing.
To save time and effort, systems should be carefully checked to
identify the causes of poor performance. By using the following
diagnostic charts, defective components or system problems can be
quickly located. To identify problems that are specific to one system,
refer to the repair section of this manual. The charts in this section
apply to all systems.

         PREPARATION FOR TESTING

         1) Attach Low and High pressure gauges.
         2) Start engine and allow to warm up.
         3) Set system to COOL and blower to HIGH.
         4) Open car doors and hood.
         5) Run engine at fast idle for 2-3 minutes.

         AIR CONDITIONING SYSTEM PERFORMANCE CHECK

AIR CONDITIONING SYSTEM PERFORMANCE CHECK TABLE

ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ

PERFORM TESTS:                   SHOULD BE:                       IF:

ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ

Temperature Check                               Temperature Check Is:

* Switch to LOW blower.
* Close doors.
* Check outlet temperature.      35-45

ø

 F            Too warm - Check

                                                        control lever
                                                    operation, heater
                                                 water valve, cooling
                                           system and gauge readings.

ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ

PERFORM TESTS:                   SHOULD BE:                       IF:

ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ

Visual Check                                      Visual Check Shows:

* Compressor             Quiet with no leaks     Noisy - Check belts,
                                                    oil level, seals,
                                                gaskets, reed valves.

* Condenser             Free of obstructions     Blocked - Clean off.
                                                   Plugged - Flush or
                                                             replace.

* Receiver-Drier       Dry and warm to touch       Frosty - Check for
                                                 restriction, replace
                                                           desiccant.

A/C SYSTEM GENERAL DIAGNOSTIC PROCEDURES 

* High Side Lines      Dry and warm to touch       Frosty or very hot
                                                          - Check for
                                                       restriction or
                                                          overcharge.

* Low Side Lines       Dry and cool to touch           Frosty or warm
                                                          - Check for
                                                     restriction, low
                                                 charge or bad valve.

* Expansion Valve           Dry                    Frosty - Check for
                                                          moisture or
                                                   restriction. Check
                                                        sensing bulb.

* STV                  Dry and cool to touch           Frosty or warm
                                                        - Check gauge
                                                   readings for valve
                                                         malfunction.

* Evaporator           Dry and cold to touch         Freezing or warm
                                                    - Check expansion
                                                        valve, STV or
                                                        thermoswitch.

ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ

PERFORM TESTS:                   SHOULD BE:                       IF:

ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ

Gauge Readings                                    Gauge Readings are:

* High Side Gauge         See Pressure Chart     Above or below normal
                                                  - See A/C Diagnosis.

* Low Side Gauge          See Pressure Chart     Above or below normal

ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ

         AMBIENT TEMPERATURE/PRESSURE

A/C SYSTEM GENERAL DIAGNOSTIC PROCEDURES 

         EVAPORATOR TEMPERATURE/PRESSURE

Fig. 2:  Evaporator Temperature/Pressure (R-12)

         A/C DIAGNOSIS W/GAUGES FOR SYS. W/INSUFFICIENT OR NO COOLING

A/C DIAGNOSIS W/GAUGES FOR SYS. W/INSUFFICIENT OR NO COOLING TABLE

A/C SYSTEM GENERAL DIAGNOSTIC PROCEDURES 

Low Side

³

High Side

³

      Other Symptoms (1)     

³

     Diagnosis     

³

³

 Gauge  

³

  Gauge  

³

                             

³

                   

³

ÃÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ´
³

 NORMAL 

³

 NORMAL  

³

 No or few bubbles in sight  

³

Some Air & Moisture

³

³

        

³

         

³

 glass. High side gauge may  

³

in System          

³

³

        

³

         

³

 go high. Low side gauge     

³

                   

³

³

        

³

         

³

 does not fluctuate with     

³

                   

³

³

        

³

         

³

 compressor on/off cycle.    

³

                   

³

ÃÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ´
³

 NORMAL 

³

 NORMAL  

³

 Cools okay in morning but   

³

 Excessive Moisture

³

³

        

³

         

³

 not during hot part of day. 

³

 in System         

³

³

        

³

         

³

 Bubbles in sight glass.     

³

                   

³

³

        

³

         

³

 Discharge air warm when low 

³

                   

³

³

        

³

         

³

 side gauge drops into       

³

                   

³

³

        

³

         

³

 vacuum.                     

³

                   

³

ÃÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ´
³

 NORMAL 

³

 NORMAL  

³

 Thermostatic sw. sys. only- 

³

 Defective         

³

³

        

³

         

³

 compressor cycles off & on  

³

 Thermostatic Sw.  

³

³

        

³

         

³

 too rapidly.                

³

                   

³

ÃÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ´
³

 NORMAL 

³

 NORMAL  

³

 Cycling clutch sys only -   

³

Misadjusted        

³

³

  to    

³

         

³

 compressor doesn't turn on  

³

Thermostatic Sw. or

³

³

 HIGH   

³

         

³

 soon enough.                

³

Defective Pressure 

³

³

        

³

         

³

 Discharge air becomes warm  

³

Sensing Switch     

³

³

        

³

         

³

 as low side pressure rises. 

³

                   

³

ÃÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ´
³

  LOW   

³

   LOW   

³

 Bubbles in sight glass.     

³

 Low R-12 Charge   

³

³

        

³

         

³

 Outlet air slightly cool.   

³

                   

³

ÃÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ´
³

  LOW   

³

   LOW   

³

 Sight glass clear.          

³

 Excessively Low   

³

³

        

³

         

³

 Outlet air very warm.       

³

 R-12 Charge       

³

ÃÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ´
³

  LOW   

³

   LOW   

³

 Outlet air slightly cool.   

³

 Expansion Valve   

³

³

        

³

         

³

 Sweating or frost at        

³

Stuck Closed Screen

³

³

        

³

         

³

 expansion valve.            

³

 Plugged or Sensing

³

³

        

³

         

³

                             

³

 Bulb Malfunction  

³

ÃÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ´
³

  LOW   

³

   LOW   

³

 Outlet air slightly cool.   

³

 Restriction on    

³

³

        

³

         

³

High side line cool to touch.

³

 High Side         

³

³

        

³

         

³

 Sweating or frost on        

³

                   

³

³

        

³

         

³

 high side.                  

³

                   

³

ÃÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ´
³

  LOW   

³

  HIGH   

³

 Evaporator outlet pipe cold.

³

  STV Stuck Open   

³

³

        

³

         

³

 Low side goes into vacuum   

³

                   

³

³

        

³

         

³

 when blower is disconnected.

³

                   

³

ÃÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ´
³

 HIGH   

³

   LOW   

³

 Evaporator outlet pipe warm.

³

 STV Stuck Closed  

³

³

        

³

         

³

 Outlet air warm.            

³

                   

³

ÃÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ´
³

 HIGH   

³

   LOW   

³

 Noise from compressor.      

³

 Compressor        

³

³

        

³

         

³

                             

³

 Malfunction       