CONTROL VALVE WITH TCM TM-207 < REMOVAL AND INSTALLATION > C E F G H I J K L M A B TM N O P 10. Tighten bolt (1A), (2B) and (3A) temporarily to prevent disloca- tion. After that tighten them in order (1 → 2 → 3). Then tighten other bolts. 11. Tighten control valve with TCM bolts to the specified torque. 12. Connect output speed sensor connector (1). 13. Securely fasten output speed sensor (1) harness with terminal clip ( ). 14. Install oil pan to transmission case. Refer to TM-199, "Removal and Installation" . 15. Pull up A/T assembly harness connector. CAUTION: Do not damage connector. : Front Bolt symbol A B C Number of bolts 5 6 1 Length mm (in) 42 (1.65) 55 (2.17) 40 (1.57) Tightening torque 7.9 (0.81, 70) With ATF applied 7.9 (0.81, 70) SCIA8075E JSDIA1319ZZ JSDIA1316ZZ SCIA5038E |