POWER WINDOW SERIAL LINK PWC-57 < DTC/CIRCUIT DIAGNOSIS > C D E F G H I J L M A B PWC N O P 1. Turn ignition switch OFF. 2. Disconnect BCM. 3. Check continuity between BCM connector (A) and power win- dow and door lock/unlock switch RH connector (B). 4. Check continuity between BCM connector (A) and ground. Is the inspection result normal? YES >> Replace main power window and door lock/unlock switch. Refer to NO >> Repair or replace harness. BCM connector Terminal Power window and door lock/unlock switch RH con- nector Terminal Continuity M18 (A) 22 D105 (B) 16 Yes ALKIA1027ZZ BCM connector Terminal Ground Continuity M18 (A) 22 No |