EM-64 < REMOVAL AND INSTALLATION > CAMSHAFT a. Squeeze return-proof clip ends using suitable tool and push the plunger into the tensioner body. b. Secure plunger using stopper pin. • Stopper pin is made from hard wire approximately 1 mm (0.04 in) in diameter. c. Remove the bolts and the chain tensioner. NOTE: • Stop plunger in the fully extended position using return-proof clip (1) if stopper pin is removed. • Push the plunger (2) into the chain tensioner body while squeezing the return-proof clip (1). Secure it using stopper pin (3). 12. Remove the chain tensioner cover from the front cover using Tool. CAUTION: Do not damage mating surfaces. 13. Remove the chain tensioner (RH) using the following steps. WARNING: Plunger, spring, and spring seat pop out when squeezing return-proof clip without holding plunger head. It may cause serious injuries. Always hold plunger head when removing. a. Squeeze return-proof clip ends using suitable tool and push the plunger into the chain tensioner body. b. Secure plunger using stopper pin. • Stopper pin is made from hard wire approximately 1 mm (0.04 in) in diameter. KBIA2479E KBIA2483E Tool number : KV10111100 (J-37228) KBIA2521E KBIA2479E |