TM-386

< DTC/CIRCUIT DIAGNOSIS >

[CVT: RE0F11A]

P0965 PRESSURE CONTROL SOLENOID B

P0965 PRESSURE CONTROL SOLENOID B

DTC Logic

INFOID:0000000009268195

DTC DETECTION LOGIC

DTC CONFIRMATION PROCEDURE

CAUTION:

• Be sure to perform 

TM-386, "Diagnosis Procedure"

” and then perform “DTC CONFIRMATION PRO-

CEDURE”.

• Never perform “DTC CONFIRMATION PROCEDURE” before the repairs. Doing so may result in a sec-

ondary malfunction.

• Be careful of the driving speed.

1.

PREPARATION BEFORE WORK

If another "DTC CONFIRMATION PROCEDURE" occurs just before, turn ignition switch OFF and wait for at

least 10 seconds, then perform the next test.

>> GO TO 2.

2.

CHECK DTC DETECTION

1. Start the engine.

2. Drive the vehicle.

3. Maintain the following conditions for 20 seconds or more.

4. Stop the vehicle.

5. Check the first trip DTC.
Is “P0965”detected?

YES

>> Go to 

TM-386, "Diagnosis Procedure"

.

NO

>> INSPECTION END

Diagnosis Procedure

INFOID:0000000009268196

1.

CHECK INTERMITTENT INCIDENT

Refer to 

GI-45, "Intermittent Incident"

.

Is the inspection result normal?

YES 

>> Replace transaxle assembly. Refer to 

TM-452, "Removal and Installation"

.

NO

>> Repair or replace malfunctioning parts.

DTC

Trouble diagnosis name

DTC detection condition

Possible causes

P0965

Pressure control solenoid B 
control circuit range perfor-
mance

The detection conditions continuously for 5 
seconds or more under the following diagnosis 
conditions:
• Diagnosis conditions
- Selector lever: Other than “P” and “N” posi-

tions

- Auxiliary gearbox shifting is not in progress.
- Engine speed: More than 500 rpm
• Detection condition A
- Actual primary pulley ratio: 2.0 – 2.4
- Target primary pulley ratio: Less than 1.2
• Detection condition B
- Actual primary pulley ratio: 0.35 – 0.75
- Target primary pulley ratio: More than 1.55

Primary pressure solenoid valve

Vehicle speed

: 20 km/h (13 MPH) or more

P0966 PRESSURE CONTROL SOLENOID B

TM-387

< DTC/CIRCUIT DIAGNOSIS >

[CVT: RE0F11A]

C

E

F

G

H

I

J

K

L

M

A

B

TM

N

O

P

P0966 PRESSURE CONTROL SOLENOID B

DTC Logic

INFOID:0000000009268197

DTC DETECTION LOGIC

DTC CONFIRMATION PROCEDURE

1.

PREPARATION BEFORE WORK

If another "DTC CONFIRMATION PROCEDURE" occurs just before, turn ignition switch OFF and wait for at

least 10 seconds, then perform the next test.

>> GO TO 2.

2.

CHECK DTC DETECTION

1. Start the engine and wait for 5 seconds or more.

2. Check the first trip DTC.
Is “P0966” detected?

YES

>> Go to 

TM-387, "Diagnosis Procedure"

.

NO

>> INSPECTION END

Diagnosis Procedure

INFOID:0000000009268198

1.

CHECK CIRCUIT BETWEEN TCM AND  CVT UNIT

1. Turn ignition switch OFF.

2. Disconnect  TCM connector and  CVT unit connector.

3. Check  continuity between TCM harness connector terminal and ground.

Is the inspection result normal?

YES 

>> GO TO 2.

NO

>> Repair or replace  malfunctioning parts.

2.

CHECK PRIMARY PRESSURE SOLENOID VALVE

Check  primary pressure solenoid valve. Refer to 

TM-387, "Component Inspection (Primary Pressure Sole-

noid Valve)"

.

Is the inspection result normal?

YES 

>> Check intermittent incident. Refer to 

GI-45, "Intermittent Incident"

.

NO

>> Repair or replace  malfunctioning parts.

Component Inspection (Primary Pressure Solenoid Valve)

INFOID:0000000009268199

1.

CHECK PRIMARY PRESSURE SOLENOID VALVE

Check  resistance between  CVT unit connector terminal and ground.

DTC

Trouble diagnosis name

DTC detection condition

Possible causes

P0966

Pressure control solenoid B 
control circuit low

The primary pressure solenoid valve current is 
200 mA or less continuously for 480 msec or 
more under the following diagnosis conditions:
• Diagnosis conditions
- Solenoid valve output current: 750 mA or 

more

- GND short circuit diagnosis occurs in the 

solenoid valve drive circuit.

- TCM power supply voltage: More than 11 V

• Harness or connector

(Primary pressure solenoid valve cir-
cuit shorted to ground)

• Primary pressure solenoid valve

TCM

Ground

Continuity

Connector

Terminal

F44

40

Ground

Not existed

TM-388

< DTC/CIRCUIT DIAGNOSIS >

[CVT: RE0F11A]

P0966 PRESSURE CONTROL SOLENOID B

Is the inspection result normal?

YES

>> INSPECTION END

NO

>> There is a malfunction of  primary pressure solenoid valve. Replace  transaxle assembly. Refer to

TM-452, "Removal and Installation"

.

CVT unit

Ground

Condition

Resistance

Terminal

3

Ground

CVT fluid temperature: 20

°C (68°F)

Approx. 5.3 

CVT fluid temperature: 50

°C (122°F)

Approx. 6.0 

CVT fluid temperature: 80

°C (176°F)

Approx. 6.7 

P0967 PRESSURE CONTROL SOLENOID B

TM-389

< DTC/CIRCUIT DIAGNOSIS >

[CVT: RE0F11A]

C

E

F

G

H

I

J

K

L

M

A

B

TM

N

O

P

P0967 PRESSURE CONTROL SOLENOID B

DTC Logic

INFOID:0000000009268200

DTC DETECTION LOGIC

DTC CONFIRMATION PROCEDURE

1.

PREPARATION BEFORE WORK

If another "DTC CONFIRMATION PROCEDURE" occurs just before, turn ignition switch OFF and wait for at

least 10 seconds, then perform the next test.

>> GO TO 2.

2.

CHECK DTC DETECTION

1. Start the engine and wait for 5 seconds or more.

2. Check the first trip DTC.
Is “P0967” detected?

YES

>> Go to 

TM-389, "Diagnosis Procedure"

.

NO

>> INSPECTION END

Diagnosis Procedure

INFOID:0000000009268201

1.

CHECK CIRCUIT BETWEEN TCM AND  CVT UNIT

1. Turn ignition switch OFF.

2. Disconnect  TCM connector and  CVT unit connector.

3. Check  continuity between  TCM harness connector terminal and  CVT unit harness connector terminal.

Is the inspection result normal?

YES 

>> GO TO 2.

NO

>> Repair or replace  malfunctioning parts.

2.

CHECK PRIMARY PRESSURE SOLENOID VALVE

Check  primary pressure solenoid valve. Refer to 

TM-389, "Component Inspection (Primary Pressure Sole-

noid Valve)"

.

Is the inspection result normal?

YES 

>> Check intermittent incident. Refer to 

GI-45, "Intermittent Incident"

.

NO

>> Repair or replace  malfunctioning parts.

Component Inspection (Primary Pressure Solenoid Valve)

INFOID:0000000009268202

1.

CHECK PRIMARY PRESSURE SOLENOID VALVE

Check  resistance between  CVT unit connector terminal and ground.

DTC

Trouble diagnosis name

DTC detection condition

Possible causes

P0967

Pressure control solenoid B 
control circuit high

The primary pressure solenoid valve current is 
200 mA or less continuously for 200 msec or 
more under the following diagnosis conditions:
• Diagnosis conditions
- Solenoid valve output current: 750 mA or 

more

- GND short diagnosis of the solenoid valve 

circuit is not satisfied. 

- TCM power supply voltage: More than 11 V

• Harness or connector

(Primary pressure solenoid valve cir-
cuit open or shorted to power supply)

• Primary pressure solenoid valve

TCM

CVT unit

Continuity

Connector

Terminal

Connector

Terminal

F44

40

F46

3

Existed

 

 

 

 

 

 

 