MWI PRECAUTIONS MWI-3 < PRECAUTION > C D E F G H I J K L M B A O P PRECAUTION PRECAUTIONS Precaution for Technicians Using Medical Electric INFOID:0000000010122379 OPERATION PROHIBITION WARNING: • Parts with strong magnet is used in this vehicle. • Technicians using a medical electric device such as pacemaker must never perform operation on the vehicle, as magnetic field can affect the device function by approaching to such parts. NORMAL CHARGE PRECAUTION WARNING: • If a technician uses a medical electric device such as an implantable cardiac pacemaker or an implantable cardioverter defibrillator, the possible effects on the devices must be checked with the device manufacturer before starting the charge operation. • As radiated electromagnetic wave generated by on board charger at normal charge operation may effect medical electric devices, a technician using a medical electric device such as implantable car- diac pacemaker or an implantable cardioverter defibrillator must not enter the vehicle compartment (including luggage room) during normal charge operation. PRECAUTION AT TELEMATICS SYSTEM OPERATION WARNING: • If a technician uses implantable cardiac pacemaker or implantable cardioverter defibrillator (ICD), avoid the device implanted part from approaching within approximately 220 mm (8.66 in) from inte- rior/exterior antenna. • The electromagnetic wave of TCU might affect the function of the implantable cardiac pacemaker or the implantable cardioverter defibrillator (ICD), when using the service, etc. • If a technician uses other medical electric devices than implantable cardiac pacemaker or implant- able cardioverter defibrillator (ICD), the electromagnetic wave of TCU might affect the function of the device. The possible effects on the devices must be checked with the device manufacturer before TCU use. PRECAUTION AT INTELLIGENT KEY SYSTEM OPERATION WARNING: • If a technician uses implantable cardiac pacemaker or implantable cardioverter defibrillator (ICD), avoid the device implanted part from approaching within approximately 220 mm (8.66 in) from inte- rior/exterior antenna. • The electromagnetic wave of intelligent key might affect the function of the implantable cardiac pacemaker or the implantable cardioverter defibrillator (ICD), at door operation, at each request switch operation, or at engine starting. • If a technician uses other medical electric devices than implantable cardiac pacemaker or implant- able cardioverter defibrillator (ICD), the electromagnetic wave of intelligent key might affect the func- tion of the device. The possible effects on the devices must be checked with the device manufacturer before intelligent key use. Point to Be Checked Before Starting Maintenance Work INFOID:0000000010122380 The high voltage system may starts automatically. It is required to check that the timer air conditioner and timer charge (during EVSE connection) are not set before starting maintenance work. NOTE: If the timer air conditioner or timer charge (during EVSE connection) is set, the high voltage system starts automatically even when the power switch is in OFF state. Precaution for Supplemental Restraint System (SRS) "AIR BAG" and "SEAT BELT INFOID:0000000010122381 The Supplemental Restraint System such as “AIR BAG” and “SEAT BELT PRE-TENSIONER”, used along with a front seat belt, helps to reduce the risk or severity of injury to the driver and front passenger for certain types of collision. This system includes seat belt switch inputs and dual stage front air bag modules. The SRS |