Content .. 1251 1252 1253 1254 ..
VSP-32 < ECU DIAGNOSIS INFORMATION > APPROACHING VEHICLE SOUND FOR PEDESTRIANS (VSP) CONTROL UNIT VSP SOUND READY When VSP system sound is not cancelled. ON When VSP system sound is cancelled. OFF PUSH SW Power switch When power switch is pressed. ON When power switch is not pressed. OFF READY OP IND SIG READY ON When READY starts. BLINK Other than the above. OFF CHARGE SOUND REQ Charge sound is not operating. OFF Charge connector connected. PLG IN • When charge starts. CHR ST • When charge port lid is unlocked. UNLCK REVERSE BUZZER NOTE: OFF VEHICLE SPEED Power switch While driving. Approximately equal to VHCL SPEED SIG Power switch Vehicle speed signal is normal. NORMAL Vehicle speed signal is abnormal. INVALID SHIFT POS SIG Power switch When selector lever is in “P” position. P When selector lever is in “N” position. N When selector lever is in “R” position. R When selector lever is in “D” position. D ENGINE RPM NOTE: rpm ENG SPEED SIG NOTE: NORMAL START UP SOUND REQ Power switch When start up sound setting in the combination 1 When start up sound setting in the combination 2 When start up sound setting in the combination 3 When start up sound setting in the combination OFF SOUND SET REQ Power switch When start up sound type was set. ON Other than the above. OFF Monitor item Condition Value/Status |