PG-140 < BASIC INSPECTION > BATTERY CHARGING CHART • Keep battery away from open flame while it is being charged. this may cause a spark. • If battery temperature rises above 55 ° C (131 ° F), stop charging. Always charge battery when its tem- perature is below 55 ° C (131 ° F). Standard Charge INFOID:0000000005911879 1. DETERMINE INITIAL CHARGING CURRENT 1. Determine initial charging current from specific gravity. 2. Check battery type and determine the specified current using the table. NOTE: Initial Charging Current Setting (Standard Charge) >> GO TO 2. 2. CHARGE BATTERY Charge battery for 8 hours. >> GO TO 3. 3. CHECKING SPECIFIC GRAVITY Check specific gravity. Refer to PG-130, "How to Handle Battery" Is the specific gravity 1.240 or more? YES >> Complete standard charge. Perform “CAPACITY TEST”. Refer to . NO >> GO TO 4. 4. CONDUCT ADDITIONAL CHARGE Add charging time depending on specific gravity. Additional Charge (Standard Charge) >> Complete standard charge. Perform “CAPACITY TEST”. Refer to . CAUTION: CONVERTED SPECIFIC GRAVITY BATTERY TYPE 28 B19 L /R 34 B19 L /R 46 B24 L /R 55 B24 L /R 50 D23 L /R 55 D23 L /R 025 [YUASA type code] 027 [YUASA type code] 80 D23 L /R 65 D26 L /R 80 D26 L /R 067 [YUASA type code] 096 [YUASA type code] 75 D31 L /R 95 D31 L /R 1 1 5 D 31 L/R 1 1 0 D 26 L/R 95 E41 L /R 13 0E4 1 L /R 1.100 - 1.130 4.0 (A) 5.0 (A) 6.0 (A) 7.0 (A) 8.0 9.0 (A) 13.0 (A) 1.130 - 1.160 3.0 (A) 4.0 (A) 5.0 (A) 6.0 (A) 7.0 8.0 (A) 11.0 (A) 1.160 - 1.190 2.0 (A) 3.0 (A) 4.0 (A) 5.0 (A) 6.0 7.0 (A) 9.0 1.190 - 1.220 2.0 (A) 2.0 (A) 3.0 (A) 4.0 (A) 5.0 5.0 (A) 7.0 SPECIFIC GRAVITY CHARGING TIME (h) Below 1.150 3.5 1.150 - 1.200 2.5 1.200 - 1.240 1.5 |