DLK-210 < DTC/CIRCUIT DIAGNOSIS > AUTOMATIC BACK DOOR MAIN SWITCH Check continuity between automatic back door main switch connector and ground. Is the inspection result normal? YES >> GO TO 4. NO >> Repair or replace harness. 4. CHECK AUTOMATIC BACK DOOR MAIN SWITCH DLK-210, "Component Inspection" . Is the inspection result normal? YES >> GO TO 5. NO >> Replace automatic back door main switch. Refer to DLK-322, "Removal and Installation" . 5. CHECK INTERMITTENT INCIDENT GI-49, "Intermittent Incident" >> Inspection End. Component Inspection INFOID:0000000009175769 1. CHECK AUTOMATIC BACK DOOR MAIN SWITCH 1. Turn ignition switch OFF. 2. Disconnect automatic back door switch connector. 3. Check continuity between automatic back door main switch terminals. Is the inspection result normal? YES >> Inspection End. NO >> Replace automatic back door main switch. Refer to DLK-322, "Removal and Installation" . Automatic back door main switch Ground Continuity Connector Terminal M185 3 Yes Automatic back door main switch Condition Continuity Terminal 1 3 Automatic back door ON Yes OFF No |