AV POWER SUPPLY AND GROUND CIRCUIT AV-555 < DTC/CIRCUIT DIAGNOSIS > [PREMIUM AUDIO WITH NAVIGATION] C D E F G H I J K L M B A O P 1. CHECK FUSE Check that the following fuses are not blown. Are the fuses blown? YES >> Replace the blown fuse after repairing the affected circuit. NO >> GO TO 2. 2. CHECK POWER SUPPLY CIRCUIT 1. Turn ignition switch OFF. 2. Disconnect around view monitor control unit connector M96. 3. Check voltage between around view monitor control unit connector M96 and ground. Is the inspection result normal? YES >> GO TO 3. NO >> Repair or replace harness or connectors. 3. CHECK GROUND CIRCUIT 1. Turn ignition switch OFF. 2. Check continuity between around view monitor control unit connector M96 and ground. Is the inspection result normal? YES >> Inspection End. NO >> Repair or replace harness or connectors. Terminal No. Signal name Fuse No. 4 Ignition signal 29 (5A) 2 Battery power supply 15 (15A) Around view monitor control unit Ground Condition Voltage (Approx.) Connector Terminal M96 3 — Ignition switch: ON Battery voltage 2 Ignition switch: OFF Around view monitor control unit Ground Continuity Connector Terminal M96 1 — Yes |