содержание .. 844 845 846 847 ..
ECM EC-513 < ECU DIAGNOSIS INFORMATION > [QR25DE] C D E F G H I J K L M A EC N P O : Average voltage for pulse signal (Actual pulse signal can be confirmed by oscilloscope.) Fail Safe INFOID:0000000010986262 NON DTC RELATED ITEM 117 128 (BR) PNP signal Input [Ignition switch: ON] Battery voltage (11 - 14 V) [Ignition switch: ON] 0 V 118 (SB) — Sensor power supply — [Ignition switch: ON] 5.0 V 119 (Y) 120 (LG) Accelerator pedal posi- Input [Ignition switch: ON] 0.25 - 0.5 V [Ignition switch: ON] 2.0 - 2.5 V 120 (LG) — Sensor ground — — — 121 (BR) 128 (BR) Power supply for ECM Input [Ignition switch: ON] Battery voltage (11 - 14 V) 122 (V) — Sensor power supply — [Ignition switch: ON] 5.0 V 123 (BR) — ECM ground — — — 124 — Sensor ground — — — 126 (GR) 127 (R) Accelerator pedal posi- Input [Ignition switch: ON] 0.5 - 1.0 V [Ignition switch: ON] 4.2 - 4.8 V 127 (R) — Sensor ground — — — 128 (BR) — ECM ground — — — Terminal No. (Wire color) Description Condition Value (Approx.) + − Signal name Input/ Output |