Content .. 1791 1792 1793 1794 ..
WW-50 < DTC/CIRCUIT DIAGNOSIS > FRONT WIPER MOTOR HI CIRCUIT RHD 4. Check continuity between IPDM E/R harness connector and ground. Is the inspection result normal? YES >> Replace IPDM E/R. Refer to PCS-67, "Removal and Installation" NO >> Repair or replace harness. IPDM E/R Front wiper motor Continuity Connector Terminal Connector Terminal E39 43 E63 1 Existed IPDM E/R Ground Continuity Connector Terminal E39 43 Not existed |