Content .. 1289 1290 1291 1292 ..
HAZARD FUNCTION DLK-433 < DTC/CIRCUIT DIAGNOSIS > [TYPE 3] C D E F G H I J L M A B DLK N O P HAZARD FUNCTION Component Function Check INFOID:0000000010434993 1. CHECK FUNCTION 1. Select “MULTI REMOTE ENT” of “BCM” using CONSULT. 2. Select “FLASHER” in “ACTIVE TEST” mode. 3. Check that the function operates normally according to the following conditions. Is the inspection result normal? YES >> Hazard warning lamp circuit is OK. NO >> Refer to DLK-433, "Diagnosis Procedure" Diagnosis Procedure INFOID:0000000010434994 1. CHECK HAZARD SWITCH CIRCUIT EXL-144, "Component Function Check" Is the inspection result normal? YES >> GO TO 2. NO >> Repair or replace the malfunctioning parts. 2. CHECK INTERMITTENT INCIDENT GI-44, "Intermittent Incident" . >> INSPECTION END Monitor item Status FLASHER LH Front turn signal lamp LH Turns ON RH Front turn signal lamp RH Turns ON OFF Front turn signal lamp Turns OFF |