Content .. 1044 1045 1046 1047 ..
HA-10 < PRECAUTION > [TYPE 1] PRECAUTIONS • Refrigerant pressure sensor to high-pressure pipe1 WARNING: Check that all refrigerant is discharged into the recycling equipment and the pressure in the system is CAUTION: Observe the following when replacing or cleaning refrigerant cycle components. to do so will cause lubricant to enter the low-pressure chamber. • Use always a torque wrench and a back-up wrench when connecting tubes. Never remove the seal caps of pipes and other components until just before required for connection. • Allow components stored in cool areas to warm to working area temperature before removing seal caps. This prevents condensation from forming inside A/C components. • Remove thoroughly moisture from the refrigeration system before charging the refrigerant. apply lubricant to threaded portion. • O-ring must be closely attached to the groove portion of tube. installed to tube correctly. • Perform leakage test and make sure that there is no leakage from connections after connecting line. Disconnect that line and replace the O-ring when the refrigerant leaking point is found. Then tighten COMPRESSOR CAUTION: • Plug all openings to prevent moisture and foreign matter from entering. compressor. Refer to • Keep friction surfaces between clutch and pulley clean. Wipe it off by using a clean waste cloth moistened with thinner if the surface is contaminated with lubricant. • Turn the compressor shaft by hand more than five turns in both directions after compressor service operation. This distributes equally lubricant inside the compressor. Let the engine idle and operate • Apply voltage to the new one and check for normal operation after replacing the compressor magnet clutch. Name : ND-OIL12 RHA861F |