|
|
содержание .. 1165 1166 1167 1168 ..
SEC-40 < COMPONENT DIAGNOSIS > [WITH INTELLIGENT KEY SYSTEM] KEY SWITCH 3. Check voltage between key switch and ignition knob switch con- Is the inspection result normal? YES >> GO TO 3. NO >> Repair or replace harness. 3. CHECK KEY SWITCH SIGNAL CIRCUIT 1. Check continuity between Intelligent Key unit harness connector 2. Check continuity between Intelligent Key unit harness connector (A) M52 terminal 7 and ground. Is the inspection result normal? YES >> GO TO 4. NO >> Repair or replace harness. 4. CHECK KEY SWITCH Check key switch function. SEC-41, "Component Inspection" . Is the inspection result normal? YES >> GO TO 5. NO >> Replace key switch and ignition knob switch. 5. CHECK INTERMITTENT INCIDENT ALKIA0768ZZ Terminals Voltage (V) (Approx.) (+) (–) key switch and ignition knob switch connector Terminal M32 2 Ground Battery voltage ALKIA0769ZZ Intelligent Key unit connector Terminal key switch and ignition knob switch connector Terminal Continuity M52 7 M32 1 Yes Intelligent Key unit harness connector Terminal Ground Continuity M52 7 Ground No |