содержание .. 105 106 107 108 ..
CHG-6 < BASIC INSPECTION > [HR16DE] DIAGNOSIS AND REPAIR WORKFLOW NOTE: 1. PRELIMINARY INSPECTION Perform the preliminary inspection. Refer to CHG-37, "Inspection Procedure" . >> GO TO 2 2. DISABLE THE POWER GENERATION VOLTAGE VARIABLE CONTROL SYSTEM Disable the power generation voltage variable control with either of the following procedures. value to 0 % by selecting “ALTERNATOR DUTY” with “Active Test”. Continue “Active Test” until the end of • Turn the ignition switch OFF, disconnect the battery current sensor connector and leave it disconnected dur- ing the course of the test. NOTE: >> GO TO 3 3. DIAGNOSIS WITH STARTING/CHARGING SYSTEM TESTER Perform the charging system test using Starting/Charging System Tester (J-44373). For details and operating Test result CHARGING SYSTEM NOMAL>>Charging system is normal and will also show “DIODE RIPPLE” test result. Charging System Tester (J-44373) to confirm repair. DIODE RIPPLE NOT DETECTED>>GO TO 4 4. INSPECTION WITH CHARGE WARNING LAMP (IGNITION SWITCH IS ON) Turn the ignition switch ON. YES >> GO TO 6 NO >> GO TO 5 5. TERMINAL“2” (OPEN) CIRCUIT INSPECTION Check terminal “2” circuit for open circuits. Refer to Is the terminal “2” circuit normal? YES >> Replace generator. NO >> Repair as needed. 6. INSPECTION WITH CHARGE WARNING LAMP (IDLING) Start the engine and run it at idle. Does the charge warning lamp turn OFF? YES >> GO TO 9 NO >> GO TO 7 7. TERMINAL “2”(SHORT) CIRCUIT INSPECTION Check terminal “2” circuit for short to ground. Refer to Is the terminal “2” circuit normal? |