Symptom List: FRONT AND REAR BLOWER OUTPUT 1 OPEN Test Note: All symptoms listed above are diagnosed using the same tests. The title for the tests will be FRONT AND REAR BLOWER When Monitored and Set Condition: FRONT AND REAR BLOWER OUTPUT 1 OPEN When Monitored: Continuously. Set Condition: If the FCM detects no voltage present on the Front/Rear Blower Motor Relay Control circuit. FRONT AND REAR BLOWER OUTPUT 2 OPEN When Monitored: Continuously. Set Condition: If the FCM detects no voltage present on the Front/Rear Blower Motor Relay Control circuit. POSSIBLE CAUSES FRONT & REAR BLOWER OUTPUT 1/2 OPEN TEST ACTION APPLICABILITY 1 View repair. All Repair Refer to symptom Front and Rear Blower Output 1 Open or 219 AUTOMATIC TEMPERATURE CONTROL |