Polaris ACE 570 (2018 year). Instruction - part 11

 

  Index      Snowmobiles / ATV     Polaris ACE 570 - instruction 2018 year

 

Search            copyright infringement  

 

 

 

 

 

 

 

 

 

Content   ..  9  10  11  12   ..

 

 

Polaris ACE 570 (2018 year). Instruction - part 11

 

 

48

FEATURES AND CONTROLS

Instrument Cluster

Diagnostic Display Code Definitions

Diagnostic Codes

Component

Condition

SPN

FMI

Intake Air 

Temperature Sensor

Data Erratic, Intermittent Or Incorrect

105

2

Voltage Above Normal, Or Shorted To High Source

105

3

Voltage Below Normal, Or Shorted To Low Source

105

4

Abnormal Rate Of Change

105

10

Data Valid But Above Normal Operating Range - Least 

Severe Level

105

15

Engine Temperature 

Sensor

Data Valid But Above Normal Operational Range - Most 

Severe Level

110

0

Data Erratic, Intermittent Or Incorrect

110

2

Voltage Above Normal, Or Shorted To High Source

110

3

Voltage Below Normal, Or Shorted To Low Source

110

4

Abnormal Rate Of Change

110

10

Data Valid But Above Normal Operating Range - Least 

Severe Level

110

15

Data Valid But Above Normal Operating Range - Moderately 

Severe Level

110

16

Data Valid But Below Normal Operating Range - Least 

Severe Level

110

17

System Power

Data Valid But Above Normal Operational Range - Most 

Severe Level

168

0

Data Valid But Below Normal Operational Range - Most 

Severe Level

168

1

Voltage Above Normal, Or Shorted To High Source

168

3

Voltage Below Normal, Or Shorted To Low Source

168

4

Data Valid But Above Normal Operating Range - Moderately 

Severe Level

168

16

Data Valid But Below Normal Operating Range - Moderately 

Severe Level

168

18

Engine Speed

Data Valid But Above Normal Operational Range - Most 

Severe Level

190

0

Data Valid But Below Normal Operational Range - Most 

Severe Level

190

1

Data Erratic, Intermittent Or Incorrect

190

2

Mechanical System Not Responding Or Out Of Adjustment

190

7

Received Network Data In Error

190

19

Condition Exists

190

31

Gear Sensor Signal

Data Erratic, Intermittent Or Incorrect

523

2

Voltage Above Normal, Or Shorted To High Source

523

3

Voltage Below Normal, Or Shorted To Low Source

523

4

Abnormal Update Rate

523

9

ECU Memory

Bad Intelligent Device Or Component

628

12

Out Of Calibration

628

13

Calibration

Out Of Calibration

630

13

Crankshaft Position 

Sensor

Data Erratic, Intermittent Or Incorrect

636

2

Abnormal Frequency Or Pulse Width Or Period

636

8

Injector 1 (Front) 

(MAG) (SDI Port 

Injector)

Voltage Above Normal, Or Shorted To High Source

651

3

Voltage Below Normal, Or Shorted To Low Source

651

4

Current Below Normal Or Open Circuit

651

5

49

FEATURES AND CONTROLS

Instrument Cluster

Diagnostic Display Code Definitions

Diagnostic Codes

Component

Condition

SPN

FMI

Fan Relay Driver 

Circuit

Voltage Above Normal, Or Shorted To High Source

1071

3

Voltage Below Normal, Or Shorted To Low Source

1071

4

Current Below Normal Or Open Circuit

1071

5

Ignition Coil Primary 

Driver 1 (Front) 

(MAG)

Voltage Above Normal, Or Shorted To High Source

1268

3

Voltage Below Normal, Or Shorted To Low Source

1268

4

Current Below Normal Or Open Circuit

1268

5

Fuel Pump Driver 

Circuit

Voltage Above Normal, Or Shorted To High Source

1347

3

Voltage Below Normal, Or Shorted To Low Source

1347

4

Current Below Normal Or Open Circuit

1347

5

Oxygen Sensor 1

Data Erratic, Intermittent Or Incorrect

3056

2

Voltage Above Normal, Or Shorted To High Source

3056

3

Voltage Below Normal, Or Shorted To Low Source

3056

4

Bad Intelligent Device Or Component

3056

12

ECU Output Supply 

Voltage 1

Data Valid But Above Normal Operational Range - Most 

Severe Level

3597

0

Data Valid But Below Normal Operational Range - Most 

Severe Level

3597

1

Voltage Above Normal, Or Shorted To High Source

3597

3

Voltage Below Normal, Or Shorted To Low Source

3597

4

Data Valid But Above Normal Operating Range - Moderately 

Severe Level

3597

16

Data Valid But Below Normal Operating Range - Moderately 

Severe Level

3597

18

ECU Output Supply 

Voltage 2

Data Valid But Above Normal Operational Range - Most 

Severe Level

3598

0

Data Valid But Below Normal Operational Range - Most 

Severe Level

3598

1

Voltage Above Normal, Or Shorted To High Source

3598

3

Voltage Below Normal, Or Shorted To Low Source

3598

4

Data Valid But Above Normal Operating Range - Moderately 

Severe Level

3598

16

Data Valid But Below Normal Operating Range - Moderately 

Severe Level

3598

18

ECU Output Supply 

Voltage 3

Data Valid But Above Normal Operational Range - Most 

Severe Level

3599

0

Data Valid But Below Normal Operational Range - Most 

Severe Level

3599

1

Voltage Above Normal, Or Shorted To High Source

3599

3

Voltage Below Normal, Or Shorted To Low Source

3599

4

Data Valid But Above Normal Operating Range - Moderately 

Severe Level

3599

16

Data Valid But Below Normal Operating Range - Moderately 

Severe Level

3599

18

ETC Accelerator 

Position Sensor 

Outputs 1 & 2 

Correlation

Data Erratic, Intermittent Or Incorrect

65613

2

50

FEATURES AND CONTROLS

Instrument Cluster

Diagnostic Display Code Definitions

Diagnostic Codes

Component

Condition

SPN

FMI

Throttle Position Sensor 2

Data Valid But Above Normal Operational Range - 

Most Severe Level

520198

0

Data Valid But Below Normal Operational Range - 

Most Severe Level

520198

1

Data Erratic, Intermittent Or Incorrect

520198

2

Voltage Above Normal, Or Shorted To High Source

520198

3

Voltage Below Normal, Or Shorted To Low Source

520198

4

Abnormal Rate Of Change

520198

10

Out Of Calibration

520198

13

Active Descent Control 

System

Voltage Above Normal, Or Shorted To High Source

520203

3

Voltage Below Normal, Or Shorted To Low Source

520203

4

Current Below Normal Or Open Circuit

520203

5

Fuel Correction Front

Data Valid But Above Normal Operating Range - 

Least Severe Level

520204

15

Data Valid But Below Normal Operating Range - 

Least Severe Level

520204

17

All Wheel Drive Control 

Circuit

Voltage Above Normal, Or Shorted To High Source

520207

3

Voltage Below Normal, Or Shorted To Low Source

520207

4

Current Below Normal Or Open Circuit

520207

5

Oxygen Sensor Heater 1

Data Erratic, Intermittent Or Incorrect

520209

2

Voltage Above Normal, Or Shorted To High Source

520209

3

Voltage Below Normal, Or Shorted To Low Source

520209

4

Current Below Normal Or Open Circuit

520209

5

Accelerator Position/Brake 

Position Interaction

Condition Exists

520275

31

Throttle Position Sensor (1 

or 2 Indeterminable)

Data Erratic, Intermittent Or Incorrect

520276

2

Bad Intelligent Device Or Component

520276

12

Throttle Body Control - 

Power Stage

Data Erratic, Intermittent Or Incorrect

520277

2

Voltage Above Normal, Or Shorted To High Source

520277

3

Voltage Below Normal, Or Shorted To Low Source

520277

4

Abnormal Frequency Or Pulse Width Or Period

520277

8

Condition Exists

520277

31

Throttle Body Control - 

Return Spring Check Failed

Condition Exists

520278

31

Throttle Body Control - 

Adaption Aborted

Condition Exists

520279

31

Throttle Body Control - 

Limp Home Position Check 

Failed

Condition Exists

520280

31

Throttle Body Control - 

Mechanical Stop 

Adaptation Failure

Condition Exists

520281

31

Throttle Body Control - 

Repeated Adaptation 

Failed

Condition Exists

520282

31

Throttle Body Control

Data Erratic, Intermittent Or Incorrect

520283

2

Voltage Above Normal, Or Shorted To High Source

520283

3

Voltage Below Normal, Or Shorted To Low Source

520283

4

51

FEATURES AND CONTROLS

Instrument Cluster

Diagnostic Display Code Definitions

Diagnostic Codes

Component

Condition

SPN

FMI

Throttle Body Control - Position Deviation 

Fault

Condition Exists

520284

31

ECU Monitoring Error

Condition Exists

520286

31

ECU Monitoring Error (Level 3)

Condition Exists

520287

31

ECU Monitoring of Injection Cut Off 

(Level 1)

Condition Exists

520288

31

ECU Monitoring of Injection Cut Off 

(Level 2)

Condition Exists

520289

31

Throttle Body Control - Requested 

Throttle Angle Not Plausible

Condition Exists

520305

31

ECU ADC Fault - No Load

Condition Exists

520306

31

ECU ADC Fault - Voltage

Condition Exists

520307

31

Accelerator Sensor Sync Fault - Sensor 

Diff Exceeds Limit

Condition Exists

520308

31

ECU Fault - ICO

Condition Exists

520309

31

ECU Fault - Hardware Disruption

Condition Exists

520311

31

Idle Fuel Correction Bank 1

Data Valid But Above Normal 

Operating Range - Least Severe

520342

15

Data Valid But Below Normal 

Operating Range - Least Severe

520342

17

Adaptive Fuel Correction Bank 1

Data Valid But Above Normal 

Operating Range - Least Severe

520344

15

Data Valid But Below Normal 

Operating Range - Least Severe

520344

17

 

 

 

 

 

 

 

Content   ..  9  10  11  12   ..