T.O. GR1F16CJ1CL2 A10 OTHER CONSIDERATIONS: 1 C Illumination of the MAIN GEN light after a 23 second loss of power to the HUD, MFD's, and other cockpit instruments indicates shorting failure of an OCSC or other wiring/equip ment. 2 With standby generator failure and the MAL & IND LTS sw in DIM, the ELEC SYS caution light may not appear to illuminate when the MASTER CAUTION and STBY GEN lights illuminate. 3 This action may reset the main or standby generator. Cycling the MAIN PWR sw may also reset the main generator; however, this action momentarily removes standby generator power and activates the EPU. 4 F The nonessential dc buses and essential dc bus lose power. This results in loss of power to fuel boost and transfer pumps, CARA, ECM, and FCR and power for normal weapon arming/release including selective jettison. F If the affected systems are required for the safe recovery of the aircraft, consider delaying/terminating EPU operation until the systems are no longer required. A10 7 3/4 " Page |