INDIAN RAILWAYS MAINTENANCE MANUAL FOR DIESEL LOCOMOTIVES - PART 23

 

  Index      Engines     INDIAN RAILWAYS MAINTENANCE MANUAL FOR DIESEL LOCOMOTIVES 2013 year

 

Search            

 

 

 

 

 

 

 

 

 

Content   ..  21  22  23  24   ..

 

 

INDIAN RAILWAYS MAINTENANCE MANUAL FOR DIESEL LOCOMOTIVES - PART 23

 

 

Document No: 

Chapter –3 Infra. Facilities of Diesel Loco Shed

 

Version No: 1.0-d0 

Date Issued: dd/mm/yyyy 

Document Title: MANUAL MAINTENANCE FOR  DIESEL LOCOMOTIVES 
 

Revised 2013 

Printed: 2015/03/08 

Page 84 of 303

 

 

S N 

Description 

C/
A/

H 

Shed Holding (Locos) 

<100 

≥100 
<175 

≥175 
<250 

464.   Lube oil dispensing system 

C 

As per shed layout  

465.   Mobile dispensing unit for Suspension Bearing oil 

  

  

  

  

466.   Pneumatic dispensing unit for cardium compound 

  

  

  

  

467.   Oil centrifuging and filtering plant (of capacity suitable to shed holding) 

C 

1 

1 

1 

468.   Electronic meters for remote relaying of data for lube oil, fuel oil, water & 

oil/greasing compound for Traction Motor gear case 

C 

As per shed layout 

469.   Compactor optimizer for storage of files 

C 

As per shed layout 

470.   Vehicle for shed in-charge 

C 

1 

1 

1 

471.   Vehicles for officers for inspection purpose 

C 

2 

3 

4 

472.   RTE based communication system 

C 

As per shed layout  

473.   Computers (having LAN connection) 

C 

30 

40 

50 

474.   Online printers 

C 

2 

3 

4 

475.   Xerox machine cum printer A3 size 

C 

2 

3 

4 

476.   Printers (of various capacities, mono/multicolor) 

C  

10 

15 

20 

477.   A0 size scanner, plotter cum copier 

C 

1 

2 

2 

478.   Fax machine  

C 

4 

6 

8 

479.   Intercom facility (With electronic exchange of 100 lines or more, as per shed 

holding) 

C 

1 

1 

1 

480.   V.H.F. SETS (Walkie-Talkie)  

C 

15 

20 

25 

481.   Video surveillance system for monitoring of shed activities (as per shed size 

and holding) 

C 

1 

1 

1 

482.   Wheel set  trolley/towing equipment for Diesel Locos 

C 

1 

2 

2 

483.   L. Laboratory Equipment 

  

  

  

  

484.   Equipment for testing lubricating oils 

  

  

  

  

485.   For viscosity determination 

  

  

  

  

486.   Constant temperature water bath for kinematic viscosity as per IS -1448 Part–I, 

P25-1960 

C 

2 

3 

4 

487.   Cannon-Fe Kinetic  Viscometer tubes calibrated No. 350 

C 

6 

8 

10 

488.   Thermometer ASTM 28 F and 46 F 

C 

6 

8 

10 

489.   Stop watches 

C 

4 

6 

8 

490.   Rubber solution bulbs (in sets) 

C 

1 

2 

3 

491.   For fuel dilution de-termination 

  

  

  

  

492.   Pensky Martens open Flash Tester with thermometers I.P. 15F and IP 16 F 

C 

1 

2 

3 

493.   Cleveland open cup ASTM-D.92 

C 

1 

2 

3 

494.   Small petrol gas generator 

C 

1 

2 

3 

495.   For water contamination test 

  

  

  

  

496.   Hot plate with variable temperature control 2000 watts. 

C 

4 

6 

8 

497.   Porcelain crucibles about 40 mm dia. (in sets) 

C 

1 

2 

3 

498.   Pair of tongs in different sizes (in sets) 

C 

4 

6 

8 

499.   Dean and stark water determination apparatus with ground glass joints 500cc 

flask 2 cc receiver and a suitable electric heater. 

C 

1 

2 

3 

500.   For ash content test. 

  

  

  

  

501.   Muffle furnace with calibrated pyrometer max temperature range up to 1000°C 

C 

1 

2 

3 

502.   Silica of Porcelain crucibles  

C 

1 

2 

3 

503.   Desiccators  

C 

1 

2 

3 

504.   Balance Analytical (preferably Chainmatic)  

C 

1 

2 

3 

505.   Balance Physical capable of reading up to 10mg 

C 

2 

3 

4 

506.   For sediment content test. 

  

  

  

  

507.   Variable speed centrifuge (as per ASTM D-893) 

C 

1 

2 

3 

508.   Centrifuge tubes cone shaped (as per ASTM D-893) 

C 

1 

2 

3 

Home 

Ch-3 

Draft

Document No: 

Chapter –3 Infra. Facilities of Diesel Loco Shed

 

Version No: 1.0-d0 

Date Issued: dd/mm/yyyy 

Document Title: MANUAL MAINTENANCE FOR  DIESEL LOCOMOTIVES 
 

Revised 2013 

Printed: 2015/03/08 

Page 85 of 303

 

 

S N 

Description 

C/
A/

H 

Shed Holding (Locos) 

<100 

≥100 
<175 

≥175 
<250 

509.   For Neutralisation value test. 

 

  

  

  

510.   Apparatus for Neutralization value determination by potentiometer titration – 

as per ASTM D-664. 

C 

2 

3 

4 

511.   Alkali resistant conical flasks capacity 250cc 

C 

4 

6 

8 

512.   Microburette 

C 

8 

12 

15 

513.   Blotter test 

 

  

  

  

514.   Whatman No1 or any good quality analytical filter paper to be used. 

C 

As per shed requirement  

515.   Miscellaneous Equipment 

  

  

  

  

516.   Air oven Range up to 150°C 

C 

1 

2 

3 

517.   Lubricating oil sampling gun. 

C 

4 

6 

8 

518.   Dark field microscope for determining qualitatively the condition of additives 

in lubricating oil 

C 

1 

2 

3 

519.   Chemicals and reagents for qualitative analysis of metals and quantitative 

analysis of water 

C 

As per shed requirement  

520.   Miscellaneous glass apparatus like test tubes breakers , flasks etc. 

C 

As per shed requirement  

521.   Equipment for Testing Greases 

  

  

  

  

522.   Penetrometer with accessories including ‘grease worker’ as per I P 50/48 or 

ASTM D-217 

C 

1 

2 

3 

523.   Drop point apparatus as per ASTM D-566 

C 

1 

2 

3 

524.   Equipment for Testing Diesel fuels : 

  

  

  

  

525.   Density/ Specific gravity test: 

  

  

  

  

526.   (i) Graduated hydrometer of floating type – Range 0.500 to 1.000 

C 

6 

8 

10 

527.   (ii) Thermometer – Range 0 to 110°C 

C 

2 

4 

6 

528.   Viscosity – Cannon Fenske viscometer tubes no. 100 

C 

2 

4 

6 

529.   Flash point-  Pensky-  Martens and closed flash point apparatus with suitable 

thermometer –IS-1448 pt. I.P.21-1960 

C 

1 

2 

3 

530.   Total Sulphur – Bomb calorimeter with accessories 

C 

1 

2 

3 

531.   Carbon residue - 

C 

  

  

  

532.   Rems bottom carbon residue apparatus including calibrated pyrometer 

C 

1 

2 

3 

533.   Cocking bulbs- Pyrex type ( for the replenished as per use) 

C 

2 

3 

4 

534.   Distillation apparatus as per ASTM D-158 with 6 Nos of distillation flasks 

C 

1 

2 

3 

535.   Thermometer ASTM 8 F 

C 

4 

6 

8 

536.   Apparatus for determination of Existent Gum content in fuels as per ASTM D-

381 

C 

1 

2 

3 

537.   Equipment for Engine Cooling Water Test : 

  

  

  

  

538.   Chloride test : 

  

  

  

  

539.   Porcelain (China) dish 80mm dia 

C 

2 

4 

6 

540.   Burettes 50 ml capacity graduated 

C 

4 

6 

8 

541.   Pocket Refractometer to determine the oil content to the emulsion 

C 

3 

4 

5 

542.   Equipment for Testing Metallic Wear 

 

  

  

  

543.   Spectrograph  

C 

1 

2 

3 

544.   Rubber Testing : 

  

  

  

  

545.   Durometer – Shore– A Hardness Tester  

C 

1 

2 

3 

546.   Electric Oven – for ageing characteristics, temperature range  up to 250 °C 

C 

2 

3 

4 

547.   Swelling Test apparatus Pyrex Beakers –  4 Branded mineral oils of known 

characteristics. 

C 

1 

2 

3 

548.   Soxhlet Apparatus  - for extraction. 

C 

1 

2 

3 

549.   Rubber Tensile Testing Machine with Dumbbelt cutters to prepare test 

specimens capacity 250 to 500 kg max. 

C 

1 

2 

3 

Home 

Ch-3 

Draft

Document No: 

Chapter –3 Infra. Facilities of Diesel Loco Shed

 

Version No: 1.0-d0 

Date Issued: dd/mm/yyyy 

Document Title: MANUAL MAINTENANCE FOR  DIESEL LOCOMOTIVES 
 

Revised 2013 

Printed: 2015/03/08 

Page 86 of 303

 

 

S N 

Description 

C/
A/

H 

Shed Holding (Locos) 

<100 

≥100 
<175 

≥175 
<250 

550.   Metal Hardness tester :  

  

  

  

  

551.   Portable Surface hardness tester 

C 

2 

3 

4 

552.   Ultrasonic Hardness Tester  

C 

4 

6 

8 

553.   Horizontal Tensile Testing Machine (40 T) 

C 

1 

2 

3 

554.   Miscellaneous Equipments 

  

  

  

  

555.   DM/RO Plant for maintenance purpose (of suitable capacity, commensurate 

with the shed holding) 

C 

1 

1 

1 

556.   Distilled water plant  

C 

1 

1 

1 

557.   RO Plants of 500 litres capacity (for shed staff) 

C 

4 

6 

8 

558.   Ultrasonic flaw detector 

C 

2 

3 

4 

559.   Zyglow testing machine 

C 

1 

2 

3 

560.   Magnetic particle testing machine 

C 

1 

2 

3 

561.   Fume Chamber 

C 

1 

2 

3 

562.   Grease debris analyzer 

C 

1 

2 

3 

563.   Electrolysis apparatus 

C 

1 

2 

3 

564.   Portable gloss-meter 

C 

1 

2 

3 

565.   Metallographs  

C 

1 

1 

1 

566.   Magna flux testing equipment 

C 

1 

2 

3 

567.   Magnifying glass 

C 

4 

6 

8 

568.   Dye  Penetration Testing Equipment 

A 

1 

2 

3 

Home 

Ch-3 

Draft

Document No: 

Chapter –4  System of Maintenance

 

Version No: 1.0-d0 

Date Issued: dd/mm/yyyy 

Document Title: MANUAL MAINTENANCE FOR  DIESEL LOCOMOTIVES 
 

Revised 2013 

Printed: 2015/03/08 

Page 87 of 303

 

 

 

INDEX 

 

Chapter 4

  

 

System of Maintenance 

 

Para No. 

Description 

Page No. 

4.1 

Objective 

89 

4.2 

Basis of Maintenance 

89 

4.3 

Maintenance Schedule 

91 

4.4 

Maintenance Methods 

91 

4.5 

Use of Advance/Diagnostic Methods for increasing the 
effectiveness of Preventive Maintenance 

91 

4.6 

Unit Exchange 

93 

4.7 

Home Sheds and Trouble Shooting Points 

93 

4.8 

Organized Preventive Maintenance 

93 

4.9 

Record keeping : Data Analysis 

101 

Annexure 4.1(a) 

Requirement of Unit Exchange Spares for ALCO  
Locos 

103 

Annexure 4.1(b) 

Requirement of Unit Exchange Spares for HHP  Locos 

104 

Annexure 4.2 

Duties and Responsibilities of Supervisors 

105 

Annexure 4.3(a) 

Syllabus for the Written test for the Post of 
Technicians Gr-III from Unskilled- Diesel 

107 

Annexure 4.3(b) 

Syllabus for the Written test for the Post of 
Technicians Gr-III from Unskilled- Electrical 

108 

Annexure 4.4(a) 

Syllabus for the Written Test for the Post of Junior 
Engineer (Mechanical) 

108 

Annexure 4.4(b) 

Syllabus for the Written Test for the Post of Junior 
Engineer (Electrical) 

109 

Annexure 4.5 

Schedule forecast Register for ALCO Locos 

109 

Annexure 4.6 

Engine Repair Book  

110 

Annexure 4.7 

Repeated Booking Register 

110 

Annexure 4.8 

O. K. Register 

111 

 

 

Ch-4 

Draft

 

 

 

 

 

 

 

Content   ..  21  22  23  24   ..