Page 8-126 Illumination, Traffic Signal Systems, Intelligent Transportation Systems, and Electrical Prior to installation all relocated metal light standards shall have existing painted All new light standards shall have an approved metal tag riveted to the pole All new and relocated metal light standards shall be numbered for identification using NN CC-SSSS VVV Where: NN = Is the pole number as identified in the Plans. May be one or more characters. CC = Is the circuit letter as identified in the Plans. May be one or more characters. SSSS = Is the service cabinet number as identified in the Plans. Do not include the two or three letter prefix. Up to four digits - do not include leading zeros. VVV = Is the operating voltage of the luminaire. Always three digits. In setting timber poles, the Contractor shall provide a minimum burial of 10 percent of the 8-20.3(13)B
Vacant 8-20.3(13)C
Luminaires The Contractor shall mark the installation date on the inside of the luminaire ballast or All luminaires shall be mounted level, both transverse and longitudinally, as measured 8-20.3(13)D
Sign Lighting Sign illumination equipment shall include fixtures, brackets, conduit, electrical wire, and . |