|
|
Content .. 1865 1866 1867 1868 ..
PG-6 < BASIC INSPECTION > [POWER SUPPLY & GROUND CIRCUIT] BATTERY YES >> GO TO 2. NO >> Replace battery. 2. CHECKING SPECIFIC GRAVITY Check specific gravity. Refer to . Inspection results Above 1.220 (Test using battery checker)>>GO TO 3. 3. CAPACITY TEST Test using battery checker. Is the battery usable, according to the manufacturer’s manuals? YES >> Ready for use. Mount battery again and check loose terminals. Also check other related circuits. NO >> GO TO 4. 4. QUICK CHARGE 1. Perform quick charge. Time required: 45 min. Refer to 2. Test using battery checker. Is the battery usable, according to the manufacturer’s manuals? YES >> Ready for use. NO >> Replace battery. 5. CAPACITY TEST 1. Test using load tester. 2. Check battery type and determine the specified current using the table. Discharging Current (Load Tester) Type Current (A) 28B19R(L) 90 34B19R(L) 99 46B24R(L) 135 55B24R(L) 50D23R(L) 150 55D23R(L) 180 80D23R(L) 195 65D26R(L) 80D26R(L) 75D31R(L) 210 95D31R(L) 240 115D31R(L) 025 [YUASA type code] 027 [YUASA type code] 285 110D26R(L) 300 95E41R(L) 067 [YUASA type code] 325 130E41R(L) 330 096 [YUASA type code] 375 LB1 (330) — LB1+ (420) — |