Nissan Qashqai (2007-2010). Manual - part 1867

 

  Index      Nissan     Nissan Qashqai - service and repair manual 2007 - 2010 year

 

Search            copyright infringement  

 

 

 

 

 

 

 

 

 

Content   ..  1865  1866  1867  1868   ..

 

 

Nissan Qashqai (2007-2010). Manual - part 1867

 

 

PG-6

< BASIC INSPECTION >

[POWER SUPPLY & GROUND CIRCUIT]

BATTERY

YES

>> GO TO 2.

NO

>> Replace battery.

2.

CHECKING SPECIFIC GRAVITY

Check specific gravity. Refer to 

PG-3, "How to Handle Battery"

.

Inspection results

Above 1.220 (Test using battery checker)>>GO TO 3.
Above 1.220 (Test using load tester)>>GO TO 5.
1.100 - 1.220 (When performing quick charge)>>GO TO 7.
1.100 - 1.220 (When performing standard charge)>>GO TO 12.
Below 1.100>>GO TO 13.

3.

CAPACITY TEST

Test using battery checker.

Is the battery usable, according to the manufacturer’s manuals?

YES

>> Ready for use. Mount battery again and check loose terminals. Also check other related circuits.

NO

>> GO TO 4.

4.

QUICK CHARGE

1.

Perform quick charge. Time required: 45 min. Refer to 

PG-116, "Quick Charge"

.

2.

Test using battery checker.

Is the battery usable, according to the manufacturer’s manuals?

YES

>> Ready for use.

NO

>> Replace battery.

5.

CAPACITY TEST

1.

Test using load tester.

2.

Check battery type and determine the specified current using the table.

Discharging Current (Load Tester)

Type

Current (A)

28B19R(L)

90

34B19R(L)

99

46B24R(L)

135

55B24R(L)

50D23R(L)

150

55D23R(L)

180

80D23R(L)

195

65D26R(L)

80D26R(L)

75D31R(L)

210

95D31R(L)

240

115D31R(L)

025 [YUASA type code]

027 [YUASA type code]

285

110D26R(L)

300

95E41R(L)

067 [YUASA type code]

325

130E41R(L)

330

096 [YUASA type code]

375

LB1 (330)

LB1+ (420)

PG

BATTERY

PG-7

< BASIC INSPECTION >

[POWER SUPPLY & GROUND CIRCUIT]

C

D

E

F

G

H

I

J

K

L

B

A

O

P

N

3.

Read load tester voltage when specified discharging current flows through battery for 15 seconds.

Is the voltage 9.6 V or more?

YES

>> Ready for use.

NO

>> GO TO 6.

6.

QUICK CHARGE

1.

Perform quick charge. Time required: 45 min. Refer to 

PG-116, "Quick Charge"

.

2.

Test using load tester.

Is the voltage 9.6 V or more?

YES

>> Ready for use.

NO

>> Replace battery.

7.

 QUICK CHARGE

1.

Perform quick charge. Refer to 

PG-116, "Quick Charge"

.

2.

Perform capacity test.

Test using battery checker.>>GO TO 8.
Test using load tester.>>GO TO 10.

8.

CAPACITY TEST

Test using battery checker.

Is the battery usable, according to the manufacturer’s manuals?

YES

>> Ready for use.

NO

>> GO TO 9.

9.

CHECKING SPECIFIC GRAVITY

1.

Check specific gravity. Refer to 

PG-3, "How to Handle Battery"

.

2.

Perform recharge. Refer to 

PG-116, "Quick Charge"

.

NOTE:
If battery temperature rises above 55

°

C (131

°

F), stop charging. Always charge battery when its tempera-

ture is below 55

°

C (131

°

F).

3.

Test using battery checker.

Is the battery usable, according to the manufacturer’s manuals?

YES

>> Ready for use.

NO

>> Replace battery.

10.

CAPACITY TEST

1.

Test using load tester.

2.

Check battery type and determine the specified current using the table.

Discharging Current (Load Tester)

LB2 (510)

LB2+ (600)

LB3 (720)

L3 (720)

Type

Current (A)

Type

Current (A)

28B19R(L)

90

34B19R(L)

99

46B24R(L)

135

55B24R(L)

50D23R(L)

150

55D23R(L)

180

PG-8

< BASIC INSPECTION >

[POWER SUPPLY & GROUND CIRCUIT]

BATTERY

3.

Read load tester voltage when specified discharging current flows through battery for 15 seconds.

Is the voltage 9.6 V or more?

YES

>> Ready for use.

NO

>> GO TO 11.

11.

CHECKING SPECIFIC GRAVITY

1.

Check specific gravity. Refer to 

PG-3, "How to Handle Battery"

.

2.

Perform recharge. Refer to 

PG-116, "Quick Charge"

.

NOTE:
If battery temperature rises above 55

°

C (131

°

F), stop charging. Always charge battery when its tempera-

ture is below 55

°

C (131

°

F).

3.

Test using load tester.

Is the voltage 9.6 V or more?

YES

>> Ready for use.

NO

>> Replace battery.

12.

 STANDARD CHARGE

NOTE:
“STANDARD CHARGE” is recommended if the vehicle is in storage after charging.
1.

Perform standard charge. Refer to 

PG-115, "Standard Charge"

.

2.

Perform capacity test.

Test using battery checker.>>GO TO 14.
Test using load tester.>>GO TO 15.

13.

 SLOW CHARGE

1.

Perform slow charge. Refer to 

PG-114, "Slow Charge"

.

2.

Perform capacity test.

Test using battery checker.>>GO TO 14.
Test using load tester.>>GO TO 15.

80D23R(L)

195

65D26R(L)

80D26R(L)

75D31R(L)

210

95D31R(L)

240

115D31R(L)

025 [YUASA type code]

027 [YUASA type code]

285

110D26R(L)

300

95E41R(L)

067 [YUASA type code]

325

130E41R(L)

330

096 [YUASA type code]

375

LB1 (330)

LB1+ (420)

LB2 (510)

LB2+ (600)

LB3 (720)

L3 (720)

Type

Current (A)

PG

BATTERY

PG-9

< BASIC INSPECTION >

[POWER SUPPLY & GROUND CIRCUIT]

C

D

E

F

G

H

I

J

K

L

B

A

O

P

N

14.

CAPACITY TEST

Test using battery checker.
Is the battery usable, according to the manufacturer’s manuals?

YES

>> Ready for use.

NO

>> Replace battery.

15.

CAPACITY TEST

1.

Test using load tester.

2.

Check battery type and determine the specified current using the table.

Discharging Current (Load Tester)

3.

Read load tester voltage when specified discharging current flows through battery for 15 seconds.

Is the voltage 9.6 V or more?

YES

>> Ready for use.

NO

>> Replace battery.

Type

Current (A)

28B19R(L)

90

34B19R(L)

99

46B24R(L)

135

55B24R(L)

50D23R(L)

150

55D23R(L)

180

80D23R(L)

195

65D26R(L)

80D26R(L)

75D31R(L)

210

95D31R(L)

240

115D31R(L)

025 [YUASA type code]

027 [YUASA type code]

285

110D26R(L)

300

95E41R(L)

067 [YUASA type code]

325

130E41R(L)

330

096 [YUASA type code]

375

LB1 (330)

LB1+ (420)

LB2 (510)

LB2+ (600)

LB3 (720)

L3 (720)

 

 

 

 

 

 

 

Content   ..  1865  1866  1867  1868   ..