Content .. 1377 1378 1379 1380 ..
FRONT FOG LAMP CIRCUIT EXL-221 < COMPONENT DIAGNOSIS > [HALOGEN TYPE] C D E F G H I J K M A B EXL N O P FRONT FOG LAMP CIRCUIT Component Function Check INFOID:0000000001099358 1. CHECK FRONT FOG LAMP OPERATION IPDM E/R AUTO ACTIVE TEST 1. Activate IPDM E/R auto active test. Refer to PCS-9, "Diagnosis Description" 2. Check that the front fog lamp is turned ON. CONSULT-III ACTIVE TEST 1. Select "EXTERNAL LAMP" of IPDM E/R active test item. 2. With operating the test items, check that the front fog lamp is turned ON. Is the front fog lamp turned ON? YES >> Front fog lamp circuit is normal. NO >> Refer to EXL-221, "Diagnosis Procedure" . Diagnosis Procedure INFOID:0000000001099359 1. CHECK FRONT FOG LAMP FUSE 1. Turn the ignition switch OFF. 2. Check that the following fuses are not fusing. Is the fuse fusing? YES >> GO TO 2. NO >> GO TO 3. 2. CHECK FRONT FOG LAMP SHORT CIRCUIT 1. Disconnect IPDM E/R connector and the front combination lamp connector. 2. Check continuity between the IPDM E/R harness connector and the ground. Does continuity exist? YES >> Repair the harnesses or connectors. And then replace the fuse. NO >> Replace the fuse. (Replace IPDM E/R if the fuse is fusing again.) 3. CHECK FRONT FOG LAMP BULB Check the applicable lamp bulb. YES >> GO TO 4. NO >> Replace the bulb. 4. CHECK FRONT FOG LAMP OUTPUT VOLTAGE CONSULT-III ACTIVE TEST 1. Disconnect the front combination lamp connector. 2. Turn the ignition switch ON. 3. Select "EXTERNAL LAMP" of IPDM E/R active test item. FOG : Front fog lamp ON OFF : Front fog lamp OFF Unit Location Fuse No. Capacity Front fog lamp IPDM E/R #43 15 A IPDM E/R Ground Continuity Connector Terminal RH E13 36 Not existed LH 43 |