following measurements may not apply.
Disconnect the battery ground cable. <<414-01>>
2. Check the vehicle off-load battery voltage. If below 12.5 volts, install a fully charged slave
battery for the tests and recharge the vehicle battery.
3. Connect a suitable ammeter to the battery with the negative test lead clip to the negative
battery terminal, and the positive test lead clip to the battery negative lead.
4. NOTE:
Make sure that all electrical accessories are switched off.
Operate the key fob unlock button to disarm the vehicle security system.
•
Switch the ignition to the RUN position for a 10 second duration.
•
Switch the ignition to the OFF position. Remove the key.
•
Close the vehicle doors and luggage compartment lid.
5. Monitor the ammeter reading for 30 minutes.
6. After 30 minutes the quiescent current reading should be no greater than 30 milliamps.
7. Disconnect the ammeter. Reconnect the battery ground cable. <<414-01>>